These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

247 related articles for article (PubMed ID: 22622978)

  • 1. Effect of roughness on imaging and sizing rough crack-like defects using ultrasonic arrays.
    Zhang J; Drinkwater BW; Wilcox PD
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 May; 59(5):939-48. PubMed ID: 22622978
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Longitudinal wave scattering from rough crack-like defects.
    Zhang J; Drinkwater BW; Wilcox PD
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Oct; 58(10):2171-80. PubMed ID: 21989880
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Defect characterization using an ultrasonic array to measure the scattering coefficient matrix.
    Zhang J; Drinkwater BW; Wilcox PD
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Oct; 55(10):2254-65. PubMed ID: 18986873
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The wavenumber algorithm for full-matrix imaging using an ultrasonic array.
    Hunter AJ; Drinkwater BW; Wilcox PD
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Nov; 55(11):2450-62. PubMed ID: 19049924
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ultrasonic characterization of crack-like defects using scattering matrix similarity metrics.
    Bai L; Velichko A; Drinkwater BW
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Mar; 62(3):545-59. PubMed ID: 25768820
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A model-based approach to crack sizing with ultrasonic arrays.
    Tant KM; Mulholland AJ; Gachagan A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 May; 62(5):915-26. PubMed ID: 25965684
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The application of synthetic focusing for imaging crack-like defects in pipelines using guided waves.
    Davies J; Cawley P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Apr; 56(4):759-71. PubMed ID: 19406704
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sizing Subwavelength Defects With Ultrasonic Imagery: An Assessment of Super-Resolution Imaging on Simulated Rough Defects.
    Elliott JB; Lowe MJS; Huthwaite P; Phillips R; Duxbury DJ
    IEEE Trans Ultrason Ferroelectr Freq Control; 2019 Oct; 66(10):1634-1648. PubMed ID: 31265390
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrasonic sizing of short surface cracks.
    Masserey B; Mazza E
    Ultrasonics; 2007 Jun; 46(3):195-204. PubMed ID: 17367834
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Image-based sizing of surface-breaking cracks by SH-wave array ultrasonic testing.
    Kimoto K; Ueno S; Hirose S
    Ultrasonics; 2006 Dec; 45(1-4):152-64. PubMed ID: 17005228
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Grazing-incidence small-angle X-ray scattering from a random rough surface: a self-consistent wavefunction approximation.
    Chukhovskii F
    Acta Crystallogr A; 2011 May; 67(Pt 3):200-9. PubMed ID: 21487178
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Short range scattering of the fundamental shear horizontal guided wave mode normally incident at a through-thickness crack in an isotropic plate.
    Rajagopal P; Lowe MJ
    J Acoust Soc Am; 2007 Sep; 122(3):1527. PubMed ID: 17927412
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Towards an Alternative to Time of Flight Diffraction Using Instantaneous Phase Coherence Imaging for Characterization of Crack-Like Defects.
    Gauthier B; Painchaud-April G; Le Duff A; Bélanger P
    Sensors (Basel); 2021 Jan; 21(3):. PubMed ID: 33499024
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improved detection of rough defects for ultrasonic nondestructive evaluation inspections based on finite element modeling of elastic wave scattering.
    Pettit JR; Walker AE; Lowe MJ
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Oct; 62(10):1797-808. PubMed ID: 26470042
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of ultrasonic array imaging algorithms for nondestructive evaluation.
    Jie Zhang ; Drinkwater BW; Wilcox PD
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Aug; 60(8):1732-45. PubMed ID: 25004543
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Finite Element Simulation of Ultrasonic Scattering by Rough Flaws with Multi-Scale Distortions.
    Wang Z; Zeng Z; Song Y; Li X
    Materials (Basel); 2022 Dec; 15(23):. PubMed ID: 36500129
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of the PZT Sensor Array Configuration on Lamb Wave Tomography Imaging with the RAPID Algorithm for Hole and Crack Detection.
    Wang S; Wu W; Shen Y; Liu Y; Jiang S
    Sensors (Basel); 2020 Feb; 20(3):. PubMed ID: 32041159
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fatigue-Crack Detection and Monitoring through the Scattered-Wave Two-Dimensional Cross-Correlation Imaging Method Using Piezoelectric Transducers.
    Xiao W; Yu L; Joseph R; Giurgiutiu V
    Sensors (Basel); 2020 May; 20(11):. PubMed ID: 32471102
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transmission and fluorescence angular domain optical projection tomography of turbid media.
    Vasefi F; Ng E; Kaminska B; Chapman GH; Jordan K; Carson JJ
    Appl Opt; 2009 Nov; 48(33):6448-57. PubMed ID: 19935964
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ultrasonic imaging algorithms with limited transmission cycles for rapid nondestructive evaluation.
    Moreau L; Drinkwater BW; Wilcox PD
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Sep; 56(9):1932-44. PubMed ID: 19811996
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.