These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 22628331)

  • 1. Characterisation of a highly sensitive troponin I assay and its application to a cardio-healthy population.
    Koerbin G; Tate J; Potter JM; Cavanaugh J; Glasgow N; Hickman PE
    Clin Chem Lab Med; 2012 Feb; 50(5):871-8. PubMed ID: 22628331
    [TBL] [Abstract][Full Text] [Related]  

  • 2. European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay.
    Krintus M; Kozinski M; Boudry P; Capell NE; Köller U; Lackner K; Lefèvre G; Lennartz L; Lotz J; Herranz AM; Nybo M; Plebani M; Sandberg MB; Schratzberger W; Shih J; Skadberg Ø; Chargui AT; Zaninotto M; Sypniewska G
    Clin Chem Lab Med; 2014 Nov; 52(11):1657-65. PubMed ID: 24897400
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Performance of the Advia Centaur second-generation troponin assay TnI-Ultra compared with the first-generation cTnI assay.
    van de Kerkhof D; Peters B; Scharnhorst V
    Ann Clin Biochem; 2008 May; 45(Pt 3):316-7. PubMed ID: 18482922
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Defining a reference population to determine the 99th percentile of a contemporary sensitive cardiac troponin I assay.
    Keller T; Ojeda F; Zeller T; Wild PS; Tzikas S; Sinning CR; Peetz D; Münzel T; Blankenberg S; Lackner KJ
    Int J Cardiol; 2013 Aug; 167(4):1423-9. PubMed ID: 22560907
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of high-sensitivity cardiac troponin I 99th percentile upper reference limits in a healthy Korean population.
    Ji M; Moon HW; Hur M; Yun YM
    Clin Biochem; 2016 Jul; 49(10-11):756-61. PubMed ID: 27067595
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of the Australian gender specific thresholds using the Abbott high sensitivity troponin I assay in clinical care.
    Bender R; Njue F; Vasikaran S; Lambert R; Rankin J; Hillis GS; Bell DA
    Pathology; 2017 Aug; 49(5):514-517. PubMed ID: 28689634
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Outliers affecting cardiac troponin I measurement: comparison of a new high sensitivity assay with a contemporary assay on the Abbott ARCHITECT analyser.
    Sawyer N; Blennerhassett J; Lambert R; Sheehan P; Vasikaran SD
    Ann Clin Biochem; 2014 Jul; 51(Pt 4):476-84. PubMed ID: 24056812
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analytical performance and clinical decision limit of a new release for cardiac troponin I assay.
    Moretti M; Pieretti B; Sisti D; Rocchi M; Gasperoni S
    Ann Clin Biochem; 2015 Jan; 52(Pt 1):169-72. PubMed ID: 24711561
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analytical evaluation of a new point of care system for measuring cardiac Troponin I.
    Kemper DW; Semjonow V; de Theije F; Keizer D; van Lippen L; Mair J; Wille B; Christ M; Geier F; Hausfater P; Pariente D; Scharnhorst V; Curvers J; Nieuwenhuis J
    Clin Biochem; 2017 Mar; 50(4-5):174-180. PubMed ID: 27847339
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Direct comparison of clinical decision limits for cardiac troponin T and I.
    Kimenai DM; Henry RM; van der Kallen CJ; Dagnelie PC; Schram MT; Stehouwer CD; van Suijlen JD; Niens M; Bekers O; Sep SJ; Schaper NC; van Dieijen-Visser MP; Meex SJ
    Heart; 2016 Apr; 102(8):610-6. PubMed ID: 26794233
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reference value for cardiac troponin I in a multi-ethnic group.
    Sthaneshwar P; Jamaluddin FA; Fan YS
    Pathology; 2010; 42(5):454-6. PubMed ID: 20632822
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance characteristics of five cardiac Troponin I assays.
    La'ulu SL; Roberts WL
    Clin Chim Acta; 2010 Aug; 411(15-16):1095-101. PubMed ID: 20398643
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Validation of high-sensitivity performance for a United States Food and Drug Administration cleared cardiac troponin I assay.
    Christenson RH; Mullins K; Duh SH
    Clin Biochem; 2018 Jun; 56():4-10. PubMed ID: 29750939
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High-sensitivity troponin I for risk assessment in patients with atrial fibrillation: insights from the Apixaban for Reduction in Stroke and other Thromboembolic Events in Atrial Fibrillation (ARISTOTLE) trial.
    Hijazi Z; Siegbahn A; Andersson U; Granger CB; Alexander JH; Atar D; Gersh BJ; Mohan P; Harjola VP; Horowitz J; Husted S; Hylek EM; Lopes RD; McMurray JJ; Wallentin L;
    Circulation; 2014 Feb; 129(6):625-34. PubMed ID: 24226808
    [TBL] [Abstract][Full Text] [Related]  

  • 15. What does elevated high-sensitive troponin I in stroke patients mean: concomitant acute myocardial infarction or a marker for high-risk patients?
    Anders B; Alonso A; Artemis D; Schäfer A; Ebert A; Kablau M; Fluechter S; Findeisen P; Hennerici MG; Fatar M
    Cerebrovasc Dis; 2013; 36(3):211-7. PubMed ID: 24135532
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Elevation of cardiac troponins measured after recreational resistance training.
    Savukoski T; Mehtälä L; Lindahl B; Venge P; Pettersson K
    Clin Biochem; 2015 Aug; 48(12):803-6. PubMed ID: 26116764
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analytical evaluation of a high-sensitivity troponin T assay and its clinical assessment in acute coronary syndrome.
    Chenevier-Gobeaux C; Meune C; Blanc MC; Cynober L; Jaffray P; Lefevre G
    Ann Clin Biochem; 2011 Sep; 48(Pt 5):452-8. PubMed ID: 21697353
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impact of atrial fibrillation on levels of high-sensitivity troponin I in a 75-year-old population.
    Horjen AW; Ulimoen SR; Enger S; Berge T; Ihle-Hansen H; Norseth J; Tveit A
    Scand J Clin Lab Invest; 2015 Jul; 75(4):308-13. PubMed ID: 25761493
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Age, sex, and racial influences on the Beckman Coulter AccuTnI+3 99th percentile.
    Greene DN; Leong TK; Collinson PO; Kamer SM; Huang K; Lorey TS; Go AS
    Clin Chim Acta; 2015 Apr; 444():149-53. PubMed ID: 25684454
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Troponin I measured with a high sensitivity immunoassay is significantly increased after a half marathon run.
    Lippi G; Schena F; Dipalo M; Montagnana M; Salvagno GL; Aloe R; Guidi GC
    Scand J Clin Lab Invest; 2012 Oct; 72(6):467-70. PubMed ID: 22794031
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.