These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

223 related articles for article (PubMed ID: 22635012)

  • 1. Evaluation of Eulerian and Lagrangian models for hemolysis estimation.
    Taskin ME; Fraser KH; Zhang T; Wu C; Griffith BP; Wu ZJ
    ASAIO J; 2012; 58(4):363-72. PubMed ID: 22635012
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Verification Benchmarks to Assess the Implementation of Computational Fluid Dynamics Based Hemolysis Prediction Models.
    Hariharan P; D'Souza G; Horner M; Malinauskas RA; Myers MR
    J Biomech Eng; 2015 Sep; 137(9):. PubMed ID: 26065371
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Study of flow-induced hemolysis using novel Couette-type blood-shearing devices.
    Zhang T; Taskin ME; Fang HB; Pampori A; Jarvik R; Griffith BP; Wu ZJ
    Artif Organs; 2011 Dec; 35(12):1180-6. PubMed ID: 21810113
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On Eulerian versus Lagrangian models of mechanical blood damage and the linearized damage function.
    Faghih MM; Sharp MK
    Artif Organs; 2019 Jul; 43(7):681-687. PubMed ID: 30656703
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Examining the universality of the hemolysis power law model from simulations of the FDA nozzle using calibrated model coefficients.
    Mantegazza A; Tobin N; Manning KB; Craven BA
    Biomech Model Mechanobiol; 2023 Apr; 22(2):433-451. PubMed ID: 36418603
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Strain-based blood damage estimation for computational design of ventricular assist devices.
    Gesenhues L; Pauli L; Behr M
    Int J Artif Organs; 2016 Jun; 39(4):166-70. PubMed ID: 27079416
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Practical implications of the erroneous treatment of exposure time in the Eulerian hemolysis power law model.
    Faghih MM; Craven BA; Sharp MK
    Artif Organs; 2023 Sep; 47(9):1531-1538. PubMed ID: 37032625
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A strain-based model for mechanical hemolysis based on a coarse-grained red blood cell model.
    Ezzeldin HM; de Tullio MD; Vanella M; Solares SD; Balaras E
    Ann Biomed Eng; 2015 Jun; 43(6):1398-409. PubMed ID: 25691396
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The power-law mathematical model for blood damage prediction: analytical developments and physical inconsistencies.
    Grigioni M; Daniele C; Morbiducci U; D'Avenio G; Di Benedetto G; Barbaro V
    Artif Organs; 2004 May; 28(5):467-75. PubMed ID: 15113341
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Interactive blood damage analysis for ventricular assist devices.
    Hentschel B; Tedjo I; Probst M; Wolter M; Behr M; Bischof C; Kuhlen T
    IEEE Trans Vis Comput Graph; 2008; 14(6):1515-22. PubMed ID: 18989004
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A CFD-based Kriging surrogate modeling approach for predicting device-specific hemolysis power law coefficients in blood-contacting medical devices.
    Craven BA; Aycock KI; Herbertson LH; Malinauskas RA
    Biomech Model Mechanobiol; 2019 Aug; 18(4):1005-1030. PubMed ID: 30815758
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experimental study on the Reynolds and viscous shear stress of bileaflet mechanical heart valves in a pneumatic ventricular assist device.
    Lee H; Tatsumi E; Taenaka Y
    ASAIO J; 2009; 55(4):348-54. PubMed ID: 19521236
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Innovative developments of the heart valves designed for use in ventricular assist devices.
    Goubergrits L; Affeld K; Kertzscher U
    Expert Rev Med Devices; 2005 Jan; 2(1):61-71. PubMed ID: 16293030
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prediction of hemolysis in turbulent shear orifice flow.
    Tamagawa M; Akamatsu T; Saitoh K
    Artif Organs; 1996 Jun; 20(6):553-9. PubMed ID: 8817954
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A tensor-based measure for estimating blood damage.
    Arora D; Behr M; Pasquali M
    Artif Organs; 2004 Nov; 28(11):1002-15. PubMed ID: 15504116
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Asymptotically consistent numerical approximation of hemolysis.
    Farinas MI; Garon A; Lacasse D; N'dri D
    J Biomech Eng; 2006 Oct; 128(5):688-96. PubMed ID: 16995755
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: shear stress, exposure time and hemolysis index.
    Fraser KH; Zhang T; Taskin ME; Griffith BP; Wu ZJ
    J Biomech Eng; 2012 Aug; 134(8):081002. PubMed ID: 22938355
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of shear stress accumulation on blood components in normal and dysfunctional bileaflet mechanical heart valves using smoothed particle hydrodynamics.
    Shahriari S; Maleki H; Hassan I; Kadem L
    J Biomech; 2012 Oct; 45(15):2637-44. PubMed ID: 22980575
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Research on flow characteristics in a non-blade centrifugal blood pump based on CFD technology].
    Cheng Y; Luo B; Wu W; Jiang L
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2010 Oct; 27(5):1133-7. PubMed ID: 21089685
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Review of Hemolysis Prediction Models for Computational Fluid Dynamics.
    Yu H; Engel S; Janiga G; Thévenin D
    Artif Organs; 2017 Jul; 41(7):603-621. PubMed ID: 28643335
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.