BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

248 related articles for article (PubMed ID: 22648557)

  • 1. Metaphyseal locking compression plate as an external fixator for the distal tibia.
    Tulner SA; Strackee SD; Kloen P
    Int Orthop; 2012 Sep; 36(9):1923-7. PubMed ID: 22648557
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study.
    Liu W; Yang L; Kong X; An L; Hong G; Guo Z; Zang L
    BMC Musculoskelet Disord; 2017 Jan; 18(1):26. PubMed ID: 28103852
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Combination of interfragmentary screws and locking plates in distal meta-diaphyseal fractures of the tibia: a retrospective, single-centre pilot study.
    Horn C; Döbele S; Vester H; Schäffler A; Lucke M; Stöckle U
    Injury; 2011 Oct; 42(10):1031-7. PubMed ID: 21663909
    [TBL] [Abstract][Full Text] [Related]  

  • 4. External fixation using femoral less invasive stabilization system plate in tibial proximal metaphyseal fracture.
    Zhang J; Ebraheim N; Li M; He X; Liu J; Zhu L; Yu Y
    Clin Orthop Surg; 2015 Mar; 7(1):8-14. PubMed ID: 25729513
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Locking plate as a definitive external fixator for treating tibial fractures with compromised soft tissue envelop.
    Qiu XS; Yuan H; Zheng X; Wang JF; Xiong J; Chen YX
    Arch Orthop Trauma Surg; 2014 Mar; 134(3):383-8. PubMed ID: 24362495
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative analysis of external locking plate and combined frame external fixator for open distal tibial fractures: a comprehensive assessment of clinical outcomes and financial implications.
    Bangura ML; Luo H; Zeng T; Wang M; Lin S; Chunli L
    BMC Musculoskelet Disord; 2023 Dec; 24(1):962. PubMed ID: 38082305
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A staged protocol for soft tissue management in the treatment of complex pilon fractures.
    Sirkin M; Sanders R; DiPasquale T; Herscovici D
    J Orthop Trauma; 2004 Sep; 18(8 Suppl):S32-8. PubMed ID: 15472563
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A staged protocol for soft tissue management in the treatment of complex pilon fractures.
    Sirkin M; Sanders R; DiPasquale T; Herscovici D
    J Orthop Trauma; 1999 Feb; 13(2):78-84. PubMed ID: 10052780
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Locking Compression Plate as an External Fixator for the Treatment of Tibia Infected Bone Defects.
    Xiao H; Wang S; Wang F; Dong S; Shen J; Xie Z
    Z Orthop Unfall; 2023 Jun; 161(3):311-317. PubMed ID: 34496424
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Metaphyseal locking plate as an external fixator for open tibial fracture: Clinical outcomes and biomechanical assessment.
    Ma CH; Wu CH; Jiang JR; Tu YK; Lin TS
    Injury; 2017 Feb; 48(2):501-505. PubMed ID: 27919511
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bone transport with an external fixator and a locking plate for segmental tibial defects.
    Oh CW; Apivatthakakul T; Oh JK; Kim JW; Lee HJ; Kyung HS; Baek SG; Jung GH
    Bone Joint J; 2013 Dec; 95-B(12):1667-72. PubMed ID: 24293598
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Percutaneous bridge plating of extra-articular distal fibular fracture for the management of distal tibia type III open fracture.
    Jung GH; Chung H; Baek SH; Sohn HS
    Asian J Surg; 2021 Jan; 44(1):363-368. PubMed ID: 33092962
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Locking compression plate as an external fixator in the treatment of closed distal tibial fractures.
    Zhou Y; Wang Y; Liu L; Zhou Z; Cao X
    Int Orthop; 2015 Nov; 39(11):2227-37. PubMed ID: 26183145
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Minimally invasive plate osteosynthesis with locking compression plate for distal diametaphyseal tibia fracture.
    Shrestha D; Acharya BM; Shrestha PM
    Kathmandu Univ Med J (KUMJ); 2011; 9(34):62-8. PubMed ID: 22610872
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The management of infected nonunion of tibia with a segmental defect using simultaneous fixation with a monorail fixator and a locked plate.
    Gupta S; Malhotra A; Mittal N; Garg SK; Jindal R; Kansay R
    Bone Joint J; 2018 Aug; 100-B(8):1094-1099. PubMed ID: 30062945
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Absolute or relative stability in minimal invasive plate osteosynthesis of simple distal meta or diaphyseal tibia fractures?
    Wenger R; Oehme F; Winkler J; Perren SM; Babst R; Beeres FJP
    Injury; 2017 Jun; 48(6):1217-1223. PubMed ID: 28302305
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical and radiologic outcomes associated with the use of dynamic locking screws (DLS) in distal tibia fractures.
    Acklin YP; Stöckle U; Sommer C
    Eur J Trauma Emerg Surg; 2016 Jun; 42(3):351-6. PubMed ID: 26063411
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Supercutaneous locking compression plate in the treatment of infected non-union and open fracture of the leg.
    Janssen SJ; Kloen P
    Arch Orthop Trauma Surg; 2022 Nov; 142(11):3201-3211. PubMed ID: 34350497
    [TBL] [Abstract][Full Text] [Related]  

  • 19. External Fixation Using a Locking Plate: A Reliable Way in Treating Distal Tibial Fractures.
    Zhang J; Ebraheim NA; Li M; He X; Liu J; Zhu L; Yu Y; Siddiqui S
    J Orthop Trauma; 2015 Nov; 29(11):e454-8. PubMed ID: 26492454
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis.
    Blažević D; Kodvanj J; Adamović P; Vidović D; Trobonjača Z; Sabalić S
    J Orthop Surg Res; 2022 Jan; 17(1):16. PubMed ID: 35016716
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.