These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

239 related articles for article (PubMed ID: 22651222)

  • 1. Time-weighted average sampling of airborne propylene glycol ethers by a solid-phase microextraction device.
    Shih HC; Tsai SW; Kuo CH
    J Occup Environ Hyg; 2012; 9(7):427-36. PubMed ID: 22651222
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diffusive sampling of airborne furfural by solid-phase microextraction device with on-fiber derivatization.
    Tsai SW; Kao KY
    J Chromatogr A; 2006 Sep; 1129(1):29-33. PubMed ID: 16934273
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A new approach for diffusive sampling based on SPME for occupational exposure assessment.
    Marín P; Periago JF; Prado C
    J Occup Environ Hyg; 2013; 10(3):132-42. PubMed ID: 23356408
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Time-weighted average passive sampling with a solid-phase microextraction device.
    Chen Y; Pawliszyn J
    Anal Chem; 2003 May; 75(9):2004-10. PubMed ID: 12720333
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Diffusive sampling of methylene chloride with solid phase microextraction.
    Chen CY; Hsiech C; Lin JM
    J Chromatogr A; 2006 Dec; 1137(2):138-44. PubMed ID: 17083945
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Solid phase microextraction as a short-term sampling technique for BTEX occupational exposure.
    Schüpfer PY; Huynh CK
    J Occup Environ Hyg; 2008 Aug; 5(8):490-500. PubMed ID: 18569516
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of ethylene oxide by solid-phase microextraction device with on-fiber derivatization.
    Tsai SW; Wu KK
    J Chromatogr A; 2003 Mar; 991(1):1-11. PubMed ID: 12703896
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Passive sampling of ambient ozone by solid phase microextraction with on-fiber derivatization.
    Lee IS; Tsai SW
    Anal Chim Acta; 2008 Mar; 610(2):149-55. PubMed ID: 18291125
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Time-weighted average water sampling with a diffusion-based solid-phase microextraction device.
    Ouyang G; Zhao W; Alaee M; Pawliszyn J
    J Chromatogr A; 2007 Jan; 1138(1-2):42-6. PubMed ID: 17113591
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sampling and analysis of nanoparticles with cold fibre SPME device.
    Koziel JA; Haddadi SH; Koch W; Pawliszyn J
    J Sep Sci; 2009 Jun; 32(11):1975-80. PubMed ID: 19425018
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Graphene packed needle trap device as a novel field sampler for determination of perchloroethylene in the air of dry cleaning establishments.
    Heidari M; Bahrami A; Ghiasvand AR; Emam MR; Shahna FG; Soltanian AR
    Talanta; 2015 Jan; 131():142-8. PubMed ID: 25281085
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Glycol ethers--validation procedures for tube/pump and dosimeter monitoring methods.
    Langhorst ML
    Am Ind Hyg Assoc J; 1984 Jun; 45(6):416-24. PubMed ID: 6331145
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Sampling free and particle-bound chemicals using solid-phase microextraction and needle trap device simultaneously.
    Niri VH; Eom IY; Kermani FR; Pawliszyn J
    J Sep Sci; 2009 Apr; 32(7):1075-80. PubMed ID: 19266554
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hydrolysis kinetics of propylene glycol monomethyl ether acetate in rats in vivo and in rat and human tissues in vitro.
    Domoradzki JY; Brzak KA; Thornton CM
    Toxicol Sci; 2003 Sep; 75(1):31-9. PubMed ID: 12857936
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dynamic solid phase microextraction sampling for reactive terpenes in the presence of ozone.
    Shu S; Morrison G
    Talanta; 2010 Oct; 82(5):1884-91. PubMed ID: 20875592
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Solid phase microextraction sampling for a rapid and simple on-site evaluation of volatile organic compounds emitted from building materials.
    Nicolle J; Desauziers V; Mocho P
    J Chromatogr A; 2008 Oct; 1208(1-2):10-5. PubMed ID: 18771772
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Laboratory and field validations of a solid-phase microextraction device for the determination of ethylene oxide.
    Tsai SW; Tsai ST; Wang VS; Lai JS
    J Chromatogr A; 2004 Feb; 1026(1-2):25-30. PubMed ID: 14763729
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Propylene glycol monomethyl ether occupational exposure. 3. Exposure of human volunteers.
    Devanthéry A; Berode M; Droz PO
    Int Arch Occup Environ Health; 2002 Apr; 75(4):203-8. PubMed ID: 11981652
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Time-weighted average SPME analysis for in planta determination of cVOCs.
    Sheehan EM; Limmer MA; Mayer P; Karlson UG; Burken JG
    Environ Sci Technol; 2012 Mar; 46(6):3319-25. PubMed ID: 22332592
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of fluoride in toothpaste using headspace solid-phase microextraction and gas chromatography-flame ionization detection.
    Wejnerowska G; Karczmarek A; Gaca J
    J Chromatogr A; 2007 May; 1150(1-2):173-7. PubMed ID: 17070826
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.