These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

476 related articles for article (PubMed ID: 22658451)

  • 1. Non-reference condition correction factor kNR of typical radiation detectors applied for the dosimetry of high-energy photon fields in radiotherapy.
    Chofor N; Harder D; Poppe B
    Z Med Phys; 2012 Sep; 22(3):181-96. PubMed ID: 22658451
    [TBL] [Abstract][Full Text] [Related]  

  • 2. SU-E-T-126: Non-Reference Condition Correction Factor KNR of Typical Radiation Detectors for the Dosimetry of High-Energy Photons.
    Chofor N; Poppe B; Harder D
    Med Phys; 2012 Jun; 39(6Part11):3732. PubMed ID: 28517170
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Supplementary values of the dosimetric parameters kNR and Em for various types of detectors in 6 and 15 MV photon fields.
    Chofor N; Harder D; Poppe B
    Z Med Phys; 2014 Mar; 24(1):27-37. PubMed ID: 23642543
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields.
    Czarnecki D; Zink K
    Phys Med Biol; 2013 Apr; 58(8):2431-44. PubMed ID: 23514734
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Investigation of correction factors for non-reference conditions in ion chamber photon dosimetry with Monte-Carlo simulations.
    Wulff J; Heverhagen JT; Karle H; Zink K
    Z Med Phys; 2010; 20(1):25-33. PubMed ID: 20211423
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.
    Ding GX; Duggan DM; Coffey CW
    Phys Med Biol; 2006 May; 51(10):2549-66. PubMed ID: 16675869
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Beam characteristics and stopping-power ratios of small radiosurgery photon beams.
    Ding GX; Ding F
    Phys Med Biol; 2012 Sep; 57(17):5509-21. PubMed ID: 22872136
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monte Carlo modelling of diode detectors for small field MV photon dosimetry: detector model simplification and the sensitivity of correction factors to source parameterization.
    Cranmer-Sargison G; Weston S; Evans JA; Sidhu NP; Thwaites DI
    Phys Med Biol; 2012 Aug; 57(16):5141-53. PubMed ID: 22842678
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: a PENELOPE Monte Carlo study.
    Benmakhlouf H; Sempau J; Andreo P
    Med Phys; 2014 Apr; 41(4):041711. PubMed ID: 24694131
    [TBL] [Abstract][Full Text] [Related]  

  • 10. AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams.
    Almond PR; Biggs PJ; Coursey BM; Hanson WF; Huq MS; Nath R; Rogers DW
    Med Phys; 1999 Sep; 26(9):1847-70. PubMed ID: 10505874
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Calorimetric determination of kQ factors for NE 2561 and NE 2571 ionization chambers in 5 cm x 5 cm and 10 cm x 10 cm radiotherapy beams of 8 MV and 16 MV photons.
    Krauss A; Kapsch RP
    Phys Med Biol; 2007 Oct; 52(20):6243-59. PubMed ID: 17921583
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Modeling silicon diode energy response factors for use in therapeutic photon beams.
    Eklund K; Ahnesjö A
    Phys Med Biol; 2009 Oct; 54(20):6135-50. PubMed ID: 19779220
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Low-energy photons in high-energy photon fields--Monte Carlo generated spectra and a new descriptive parameter.
    Chofor N; Harder D; Willborn K; Rühmann A; Poppe B
    Z Med Phys; 2011 Sep; 21(3):183-97. PubMed ID: 21530198
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monte Carlo simulation of MOSFET detectors for high-energy photon beams using the PENELOPE code.
    Panettieri V; Duch MA; Jornet N; Ginjaume M; Carrasco P; Badal A; Ortega X; Ribas M
    Phys Med Biol; 2007 Jan; 52(1):303-16. PubMed ID: 17183143
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Spectral distribution of particle fluence in small field detectors and its implication on small field dosimetry.
    Benmakhlouf H; Andreo P
    Med Phys; 2017 Feb; 44(2):713-724. PubMed ID: 28032369
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The mean photon energy ĒF at the point of measurement determines the detector-specific radiation quality correction factor kQ,M in (192)Ir brachytherapy dosimetry.
    Chofor N; Harder D; Selbach HJ; Poppe B
    Z Med Phys; 2016 Sep; 26(3):238-50. PubMed ID: 26387927
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Correction factors for A1SL ionization chamber dosimetry in TomoTherapy: machine-specific, plan-class, and clinical fields.
    Gago-Arias A; Rodriguez-Romero R; Sanchez-Rubio P; Miguel Gonzalez-Castano D; Gomez F; Nunez L; Palmans H; Sharpe P; Pardo-Montero J
    Med Phys; 2012 Apr; 39(4):1964-70. PubMed ID: 22482617
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Correction-less dosimetry of nonstandard photon fields: a new criterion to determine the usability of radiation detectors.
    Kamio Y; Bouchard H
    Phys Med Biol; 2014 Sep; 59(17):4973-5002. PubMed ID: 25118890
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Measurement of peak correction factor of Farmer chamber for calibration of flattening filter free (FFF) clinical photon beams].
    Kontra G; Major T; Polgár C
    Magy Onkol; 2015 Jun; 59(2):119-23. PubMed ID: 26035159
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel method for the determination of field output factors and output correction factors for small static fields for six diodes and a microdiamond detector in megavoltage photon beams.
    Casar B; Gershkevitsh E; Mendez I; Jurković S; Huq MS
    Med Phys; 2019 Feb; 46(2):944-963. PubMed ID: 30521073
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 24.