These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 2266742)

  • 1. Method for the design and analysis of a non-linear anisotropic lower limb prosthetic socket.
    Soh AK; Soh CK; Lau WS
    J Biomed Eng; 1990 Nov; 12(6):470-6. PubMed ID: 2266742
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Real-time patient-specific finite element analysis of internal stresses in the soft tissues of a residual limb: a new tool for prosthetic fitting.
    Portnoy S; Yarnitzky G; Yizhar Z; Kristal A; Oppenheim U; Siev-Ner I; Gefen A
    Ann Biomed Eng; 2007 Jan; 35(1):120-35. PubMed ID: 17120139
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation.
    Silver-Thorn MB; Childress DS
    J Rehabil Res Dev; 1996 Jul; 33(3):227-38. PubMed ID: 8823671
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Frictional action at lower limb/prosthetic socket interface.
    Zhang M; Turner-Smith AR; Roberts VC; Tanner A
    Med Eng Phys; 1996 Apr; 18(3):207-14. PubMed ID: 8718946
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket.
    Lee WC; Zhang M; Jia X; Cheung JT
    Med Eng Phys; 2004 Oct; 26(8):655-62. PubMed ID: 15471693
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Finite element modelling of a residual lower-limb in a prosthetic socket: a survey of the development in the first decade.
    Zhang M; Mak AF; Roberts VC
    Med Eng Phys; 1998 Jul; 20(5):360-73. PubMed ID: 9773689
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Finite element analysis of the contact interface between trans-femoral stump and prosthetic socket.
    Zhang L; Zhu M; Shen L; Zheng F
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1270-3. PubMed ID: 24109926
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Nonlinear elastic material property estimation of lower extremity residual limb tissues.
    Tönük E; Silver-Thorn MB
    IEEE Trans Neural Syst Rehabil Eng; 2003 Mar; 11(1):43-53. PubMed ID: 12797725
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of a non-linear finite element modelling of the below-knee prosthetic socket interface.
    Zhang M; Lord M; Turner-Smith AR; Roberts VC
    Med Eng Phys; 1995 Dec; 17(8):559-66. PubMed ID: 8564149
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Static and dynamic pressure prediction for prosthetic socket fitting assessment utilising an inverse problem approach.
    Sewell P; Noroozi S; Vinney J; Amali R; Andrews S
    Artif Intell Med; 2012 Jan; 54(1):29-41. PubMed ID: 21963113
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Generic, geometric finite element analysis of the transtibial residual limb and prosthetic socket.
    Silver-Thorn MB; Childress DS
    J Rehabil Res Dev; 1997 Apr; 34(2):171-86. PubMed ID: 9108344
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development of a finite element model of a transtibial socket liner--an initial study.
    Fisher C; Simpson G; Reynolds D
    Biomed Sci Instrum; 1999; 35():39-44. PubMed ID: 11143383
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Three-dimensional finite element analyses on the transtibial residual limb and its prosthetic socket].
    Zhang M; Mak AF; Fan Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2000 Dec; 17(4):403-6. PubMed ID: 11211825
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Finite element analysis of bone stress and strain around a distal osseointegrated implant for prosthetic limb attachment.
    Xu W; Crocombe AD; Hughes SC
    Proc Inst Mech Eng H; 2000; 214(6):595-602. PubMed ID: 11201407
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Modeling the interactions between a prosthetic socket, polyurethane liners and the residual limb in transtibial amputees using non-linear finite element analysis.
    Simpson G; Fisher C; Wright DK
    Biomed Sci Instrum; 2001; 37():343-7. PubMed ID: 11347414
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Interface load analysis for computer-aided design of below-knee prosthetic sockets.
    Reynolds DP; Lord M
    Med Biol Eng Comput; 1992 Jul; 30(4):419-26. PubMed ID: 1487943
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Finite element analysis of donning procedure of a prosthetic transfemoral socket.
    Lacroix D; Patiño JF
    Ann Biomed Eng; 2011 Dec; 39(12):2972-83. PubMed ID: 21887588
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Inertial effects on interface pressure between prosthetic socket and residual limb].
    Jia X; Zhang M; Wang R; Fan Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Jun; 22(3):468-71. PubMed ID: 16013238
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of computational analysis with clinical measurement of stresses on a below-knee residual limb in a prosthetic socket [Medical Engineering & Physics 22 (2000):607-12].
    Paul JP
    Med Eng Phys; 2001 Sep; 23(7):519-20. PubMed ID: 11686125
    [No Abstract]   [Full Text] [Related]  

  • 20. Key considerations for finite element modelling of the residuum-prosthetic socket interface.
    Steer JW; Worsley PR; Browne M; Dickinson A
    Prosthet Orthot Int; 2021 Apr; 45(2):138-146. PubMed ID: 33176573
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.