These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Sevoflurane vaporizers. Ngan J; Cashen D; Nichols G Can J Anaesth; 1999 Feb; 46(2):200. PubMed ID: 10084008 [No Abstract] [Full Text] [Related]
4. Transient sevoflurane output failure in a Datum vaporiser with concurrent foreign body. Penney JA; Hocking G; Weightman WM Anaesth Intensive Care; 2011 Mar; 39(2):313-4. PubMed ID: 21485689 [No Abstract] [Full Text] [Related]
5. Corrosion of Penlon sevoflurane vaporisers. O'Neill B; Hafiz MA; De Beer DA Anaesthesia; 2007 Apr; 62(4):421. PubMed ID: 17381596 [No Abstract] [Full Text] [Related]
6. Any which way but loose? --the significance of gas flow direction through a vaporiser. Yee S; Old S Anaesthesia; 2001 Jun; 56(6):598-600. PubMed ID: 11412191 [No Abstract] [Full Text] [Related]
7. Sevoflurane 2000 Drager Vaporiser 'locked on' during maintenance of anaesthesia. Lewis HF; Ellimah T; Singh A Anaesth Intensive Care; 2015 Nov; 43(6):788-9. PubMed ID: 26603809 [No Abstract] [Full Text] [Related]
8. Faulty spring causing a gas leak. Terry L; da Silva EJ J Clin Anesth; 2009 Aug; 21(5):382-3. PubMed ID: 19700289 [No Abstract] [Full Text] [Related]
9. Poor interlock safety with datum sevoflurane vaporisers. Gupta S Anaesthesia; 2000 Apr; 55(4):404-5. PubMed ID: 10781155 [No Abstract] [Full Text] [Related]
11. Smaller-than-expected sevoflurane concentrations using the Sevotec 5 vaporizer at low fill states and high fresh gas flows. Seropian MA; Robins B Anesth Analg; 2000 Oct; 91(4):834-6, table of contents. PubMed ID: 11004034 [TBL] [Abstract][Full Text] [Related]
14. Sevoflurane drawover anaesthesia with two Oxford Miniature Vaporizers in series. Brook PN; Perndt H Anaesth Intensive Care; 2001 Dec; 29(6):616-8. PubMed ID: 11771606 [TBL] [Abstract][Full Text] [Related]
15. Sevoflurane Output in the Isoflurane/Halothane Diamedica Draw-over Vaporiser. Tay WC; Tan WT Ann Acad Med Singap; 2015 Jul; 44(7):252-6. PubMed ID: 26377059 [TBL] [Abstract][Full Text] [Related]
16. Effect of nitrous oxide on sevoflurane vaporizer setting. Lin CY Anesthesiology; 2003 Apr; 98(4):1029; author reply 1029. PubMed ID: 12657875 [No Abstract] [Full Text] [Related]
17. An unexpected Penlon Sigma Elite Vaporizer leak. Lewis SE; Andrews JJ; Long GW Anesthesiology; 1999 Apr; 90(4):1221-4; discussion 1224-5. PubMed ID: 10201702 [No Abstract] [Full Text] [Related]
18. Mechanical ventilation of six dogs anaesthetised with isoflurane or sevoflurane delivered by a Komesaroff anaesthetic machine. Laredo FG; Belda E; Escobar M Vet Rec; 2009 Jun; 164(24):751-4. PubMed ID: 19525524 [TBL] [Abstract][Full Text] [Related]
19. The oxygen and volatile anaesthetic delivery characteristics during spontaneous ventilation using a non-rebreathing coaxial anaesthesia system. Day SK Kathmandu Univ Med J (KUMJ); 2005; 3(1):22-5. PubMed ID: 16401939 [TBL] [Abstract][Full Text] [Related]
20. The output of two sevoflurane vaporizers in the presence of helium. Carvalho B; Sanders D Br J Anaesth; 2002 May; 88(5):711-3. PubMed ID: 12067011 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]