These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 2267615)

  • 1. Unstable lumbar spine without hypermobility in postlaminectomy cases. Mechanism of symptoms and effect of spinal fusion with and without spinal instrumentation.
    Sano S; Yokokura S; Nagata Y; Young SZ
    Spine (Phila Pa 1976); 1990 Nov; 15(11):1190-7. PubMed ID: 2267615
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Spinal instrumentation in the management of degenerative disorders of the lumbar spine.
    Sidhu KS; Herkowitz HN
    Clin Orthop Relat Res; 1997 Feb; (335):39-53. PubMed ID: 9020205
    [TBL] [Abstract][Full Text] [Related]  

  • 3. "Silent" spinal dislocation in a Charcot spine occurring postlaminectomy: case report and review of literature.
    Luke DL; Bridwell KH
    J Spinal Disord; 1990 Mar; 3(1):87-92. PubMed ID: 2134416
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system.
    Stoll TM; Dubois G; Schwarzenbach O
    Eur Spine J; 2002 Oct; 11 Suppl 2(Suppl 2):S170-8. PubMed ID: 12384741
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Lumbar spine osteolysis: an entity caused by spinal instability.
    Bradford DS; Gotfried Y
    Spine (Phila Pa 1976); 1986 Dec; 11(10):1013-9. PubMed ID: 2953075
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Minimally invasive transmuscular pedicle screw fixation of the thoracic and lumbar spine.
    Ringel F; Stoffel M; Stüer C; Meyer B
    Neurosurgery; 2006 Oct; 59(4 Suppl 2):ONS361-6; discussion ONS366-7. PubMed ID: 17041505
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Techniques of internal fixation for degenerative conditions of the lumbar spine.
    Kostuik JP; Errico TJ; Gleason TF
    Clin Orthop Relat Res; 1986 Feb; (203):219-31. PubMed ID: 3955984
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Application and results of the AO internal fixation system in nontraumatic indications.
    Marchesi DG; Thalgott JS; Aebi M
    Spine (Phila Pa 1976); 1991 Mar; 16(3 Suppl):S162-9. PubMed ID: 2028333
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Spinal instrumentation for degenerative disease of the lumbar spine.
    Harrison MJ; Sundaresan N
    Mt Sinai J Med; 1991 Mar; 58(2):169-76. PubMed ID: 1857363
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Risk factors for adjacent-segment failure following lumbar fixation with rigid instrumentation for degenerative instability.
    Etebar S; Cahill DW
    J Neurosurg; 1999 Apr; 90(2 Suppl):163-9. PubMed ID: 10199244
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Adjacent segment mobility after rigid and semirigid instrumentation of the lumbar spine.
    Cakir B; Carazzo C; Schmidt R; Mattes T; Reichel H; Käfer W
    Spine (Phila Pa 1976); 2009 May; 34(12):1287-91. PubMed ID: 19455004
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Posterior fusion of the subaxial cervical spine: indications and techniques.
    Liu JK; Das K
    Neurosurg Focus; 2001 Apr; 10(4):E7. PubMed ID: 16732634
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Segmental square spinal instrumentation for posterior lumbar spinal fixation.
    Tajima N; Chosa E; Kubo S; Kuroki H; Matsumoto M
    J Spinal Disord; 1999 Jun; 12(3):240-4. PubMed ID: 10382778
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Iatrogenic Spondylolisthesis Following Open Lumbar Laminectomy: Case Series and Review of the Literature.
    Ramhmdani S; Xia Y; Xu R; Kosztowski T; Sciubba D; Witham T; Bydon A
    World Neurosurg; 2018 May; 113():e383-e390. PubMed ID: 29454126
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Adjacent segment degeneration after lumbosacral fusion in spondylolisthesis: a retrospective radiological and clinical analysis].
    Zencica P; Chaloupka R; Hladíková J; Krbec M
    Acta Chir Orthop Traumatol Cech; 2010 Apr; 77(2):124-30. PubMed ID: 20447355
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Protective effects of preserving the posterior complex on the development of adjacent-segment degeneration after lumbar fusion: clinical article.
    Liu H; Wu W; Li Y; Liu J; Yang K; Chen Y
    J Neurosurg Spine; 2013 Aug; 19(2):201-6. PubMed ID: 23768024
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical experiences with a PEEK-based dynamic instrumentation device in lumbar spinal surgery: 2 years and no more.
    Oikonomidis S; Ashqar G; Kaulhausen T; Herren C; Siewe J; Sobottke R
    J Orthop Surg Res; 2018 Aug; 13(1):196. PubMed ID: 30092790
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hybrid circumferential fixation for degenerative lumbosacral spine disease: posterior lumbar interbody fusion plus universal clamp rod-band instrumentation: a novel technique for lumbosacral fixation.
    Tegos S; Charitidis C; Korovessis PG
    Spine (Phila Pa 1976); 2014 Apr; 39(7):E441-9. PubMed ID: 24430716
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Adjacent instability after instrumented lumbar fusion.
    Chen WJ; Lai PL; Chen LH
    Chang Gung Med J; 2003 Nov; 26(11):792-8. PubMed ID: 14765748
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Postoperative lumbar spinal instability occurring or progressing secondary to laminectomy.
    Iida Y; Kataoka O; Sho T; Sumi M; Hirose T; Bessho Y; Kobayashi D
    Spine (Phila Pa 1976); 1990 Nov; 15(11):1186-9. PubMed ID: 2148439
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.