These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 2268249)

  • 1. Physics design for the Brookhaven Medical Research Reactor epithermal neutron source.
    Wheeler FJ; Parsons DK; Nigg DW; Wessol DE; Miller LG; Fairchild RG
    Basic Life Sci; 1990; 54():83-95. PubMed ID: 2268249
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Neutron spectrum measurements in the aluminum oxide filtered beam facility at the Brookhaven Medical Research Reactor.
    Becker GK; Harker YD; Miller LG; Anderl RA; Wheeler FJ
    Basic Life Sci; 1990; 54():235-45. PubMed ID: 2268243
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Neutron beam studies for a medical therapy reactor.
    Neuman WA
    Basic Life Sci; 1990; 54():125-39. PubMed ID: 2268234
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Design of a high-flux epithermal neutron beam using 235U fission plates at the Brookhaven Medical Research Reactor.
    Liu HB; Brugger RM; Rorer DC; Tichler PR; Hu JP
    Med Phys; 1994 Oct; 21(10):1627-31. PubMed ID: 7869995
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A calculational study of tangential and radial beams in HIFAR for neutron capture therapy.
    Harrington BV
    Basic Life Sci; 1990; 54():97-107. PubMed ID: 2268250
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Installation and testing of an optimized epithermal neutron beam at the Brookhaven Medical Research Reactor (BMRR).
    Fairchild RG; Kalef-Ezra J; Saraf SK; Fiarman S; Ramsey E; Wielopolski L; Laster BH; Wheeler FJ
    Basic Life Sci; 1990; 54():185-99. PubMed ID: 2268239
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Neutron capture therapy beam design at Harwell.
    Constantine G
    Basic Life Sci; 1990; 54():71-82. PubMed ID: 2176459
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Research on neutron beam design for BNCT at the Musashi Reactor.
    Aizawa O
    Basic Life Sci; 1990; 54():109-24. PubMed ID: 2268233
    [No Abstract]   [Full Text] [Related]  

  • 9. Boron neutron capture therapy (BNCT): implications of neutron beam and boron compound characteristics.
    Wheeler FJ; Nigg DW; Capala J; Watkins PR; Vroegindeweij C; Auterinen I; Seppälä T; Bleuel D
    Med Phys; 1999 Jul; 26(7):1237-44. PubMed ID: 10435523
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of measured parameters from a 24-keV and a broad spectrum epithermal neutron beam for neutron capture therapy: an identification of consequential parameters.
    Fairchild RG; Saraf SK; Kalef-Ezra J; Laster BH
    Med Phys; 1990; 17(6):1045-52. PubMed ID: 2280734
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monte Carlo methods of neutron beam design for neutron capture therapy at the MIT Research Reactor (MITR-II).
    Clement SD; Choi JR; Zamenhof RG; Yanch JC; Harling OK
    Basic Life Sci; 1990; 54():51-69. PubMed ID: 2268248
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Neutron capture therapy beams at the MIT Research Reactor.
    Choi JR; Clement SD; Harling OK; Zamenhof RG
    Basic Life Sci; 1990; 54():201-18. PubMed ID: 2176454
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Georgia Tech Research Reactor epithermal beam.
    Russell JL; Miller WH; Brugger RM; Herleth WH
    Basic Life Sci; 1990; 54():219-27. PubMed ID: 2268240
    [No Abstract]   [Full Text] [Related]  

  • 14. Intermediate energy neutron beams from the MURR.
    Brugger RM; Herleth WH
    Basic Life Sci; 1990; 54():153-66. PubMed ID: 2268237
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Enhancement of the epithermal neutron beam used for boron neutron capture therapy.
    Liu HB; Brugger RM; Greenberg DD; Rorer DC; Hu JP; Hauptman HM
    Int J Radiat Oncol Biol Phys; 1994 Mar; 28(5):1149-56. PubMed ID: 8175400
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Neutron-induced gamma dose from a reactor beam filter for boron neutron capture therapy.
    Harrington BV
    Pigment Cell Res; 1989; 2(4):246-53. PubMed ID: 2798318
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomedical irradiation system for boron neutron capture therapy at the Kyoto University Reactor.
    Kobayashi T; Kanda K; Ujeno Y; Ishida MR
    Basic Life Sci; 1990; 54():321-39. PubMed ID: 2176458
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A feasibility study of the Tehran research reactor as a neutron source for BNCT.
    Kasesaz Y; Khalafi H; Rahmani F; Ezati A; Keyvani M; Hossnirokh A; Shamami MA; Monshizadeh M
    Appl Radiat Isot; 2014 Aug; 90():132-7. PubMed ID: 24742535
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Increase of the beam intensity for BNCT by changing the core configuration at THOR.
    Liu HM; Peir JJ; Liu YH; Tsai PE; Jiang SH
    Appl Radiat Isot; 2009 Jul; 67(7-8 Suppl):S247-50. PubMed ID: 19394237
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A prototype epithermal neutron beam for boron neutron capture therapy.
    Noonan DJ; Russell JL; Brugger RM
    Med Phys; 1986; 13(2):211-6. PubMed ID: 3010065
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.