BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 22685349)

  • 1. Use of Cramer-Rao Lower Bound for Performance Evaluation of Different Monolithic Crystal PET Detector Designs.
    Li X; Hunter WC; Lewellen TK; Miyaoka RS
    IEEE Trans Nucl Sci; 2012; 59(1):3-12. PubMed ID: 22685349
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Performance of long rectangular semi-monolithic scintillator PET detectors.
    Zhang X; Wang X; Ren N; Hu B; Ding B; Kuang Z; Wu S; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
    Med Phys; 2019 Apr; 46(4):1608-1619. PubMed ID: 30723932
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs.
    Miyaoka RS; Li X; Lockhart C; Lewellen TK
    IEEE Trans Nucl Sci; 2010; 57(3):990-997. PubMed ID: 21614135
    [TBL] [Abstract][Full Text] [Related]  

  • 4. New Continuous Miniature Crystal Element (cMiCE) Detector Geometries.
    Miyaoka RS; Li X; Lockhart C; Lewellen TK
    IEEE Nucl Sci Symp Conf Rec (1997); 2009 Oct; 2009():3639-3642. PubMed ID: 20625465
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improving the intrinsic spatial resolution performance of the continuous miniature crystal element (cMiCE) detector.
    Ling T; Lewellen TK; Miyaoka RS
    IEEE Nucl Sci Symp Conf Rec (1997); 2007 Oct; 2007():4308-4313. PubMed ID: 21804759
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact on the Spatial Resolution Performance of a Monolithic Crystal PET Detector Due to Different Sensor Parameters.
    Li X; Lockhart C; Lewellen TK; Miyaoka RS
    IEEE Nucl Sci Symp Conf Rec (1997); 2009 Oct; 2009():3102-3105. PubMed ID: 20806058
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Study of PET Detector Performance with Varying SiPM Parameters and Readout Schemes.
    Li X; Lockhart C; Lewellen TK; Miyaoka RS
    IEEE Trans Nucl Sci; 2011; 58(3):590-596. PubMed ID: 22685348
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design of a High Resolution, Monolithic Crystal, PET/MRI Detector with DOI Positioning Capability.
    Miyaoka RS; Li X; Lockhart C; Lewellen TK
    IEEE Nucl Sci Symp Conf Rec (1997); 2008 Oct; 2008():4688-4692. PubMed ID: 20607144
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Resolution Properties of a Prototype Continuous Miniature Crystal Element (cMiCE) Scanner.
    Miyaoka RS; Li X; Hunter W; Pierce LA; McDougald W; Kinahan PE; Lewellen TK
    IEEE Trans Nucl Sci; 2011 Oct; 58(5):. PubMed ID: 24347676
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs.
    Kuang Z; Sang Z; Wang X; Fu X; Ren N; Zhang X; Zheng Y; Yang Q; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
    Med Phys; 2018 Feb; 45(2):613-621. PubMed ID: 29222959
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Depth-of-interaction positron emission tomography detector with 45° tilted silicon photomultipliers using dual-ended signal readout.
    Seo M; Park H; Lee S; Ko GB; Lee JS
    Med Phys; 2023 Jul; 50(7):4112-4121. PubMed ID: 36907664
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Calibration procedure for a continuous miniature crystal element (cMiCE) detector.
    Miyaoka RS; Ling T; Lockhart C; Lewellen TK
    IEEE Nucl Sci Symp Conf Rec (1997); 2007 Oct; 2007():4314-4318. PubMed ID: 20607104
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An edge-readout, multilayer detector for positron emission tomography.
    Li X; Ruiz-Gonzalez M; Furenlid LR
    Med Phys; 2018 Jun; 45(6):2425-2438. PubMed ID: 29635734
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Performance of a SiPM based semi-monolithic scintillator PET detector.
    Zhang X; Wang X; Ren N; Kuang Z; Deng X; Fu X; Wu S; Sang Z; Hu Z; Liang D; Liu X; Zheng H; Yang Y
    Phys Med Biol; 2017 Sep; 62(19):7889-7904. PubMed ID: 28858853
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Limits on the spatial resolution of monolithic scintillators read out by APD arrays.
    van der Laan DJ; Maas MC; Bruyndonckx P; Schaart DR
    Phys Med Biol; 2012 Oct; 57(20):6479-96. PubMed ID: 23001515
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Depth of interaction determination in monolithic scintillator with double side SiPM readout.
    Morrocchi M; Ambrosi G; Bisogni MG; Bosi F; Boretto M; Cerello P; Ionica M; Liu B; Pennazio F; Piliero MA; Pirrone G; Postolache V; Wheadon R; Del Guerra A
    EJNMMI Phys; 2017 Dec; 4(1):11. PubMed ID: 28211032
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Depth of interaction decoding of a continuous crystal detector module.
    Ling T; Lewellen TK; Miyaoka RS
    Phys Med Biol; 2007 Apr; 52(8):2213-28. PubMed ID: 17404465
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Design of a Real Time FPGA-based Three Dimensional Positioning Algorithm.
    Johnson-Williams NG; Miyaoka RS; Li X; Lewellen TK; Hauck S
    IEEE Nucl Sci Symp Conf Rec (1997); 2009 Nov; 2009():1082-3654. PubMed ID: 20625466
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance Evaluation of Small Animal PET Scanners With Different System Designs.
    Li X; Alessio AM; Burnett TH; Lewellen TK; Miyaoka R
    IEEE Trans Nucl Sci; 2013 Jun; 60(3):. PubMed ID: 24273335
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Depth-encoding using optical photon TOF in a prism-PET detector with tapered crystals.
    Zeng X; LaBella A; Wang Z; Li Y; Tan W; Goldan AH
    Med Phys; 2024 Jun; 51(6):4044-4055. PubMed ID: 38682574
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.