These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

353 related articles for article (PubMed ID: 22688340)

  • 1. Fully integrated artificial pancreas in type 1 diabetes: modular closed-loop glucose control maintains near normoglycemia.
    Breton M; Farret A; Bruttomesso D; Anderson S; Magni L; Patek S; Dalla Man C; Place J; Demartini S; Del Favero S; Toffanin C; Hughes-Karvetski C; Dassau E; Zisser H; Doyle FJ; De Nicolao G; Avogaro A; Cobelli C; Renard E; Kovatchev B;
    Diabetes; 2012 Sep; 61(9):2230-7. PubMed ID: 22688340
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multicenter outpatient dinner/overnight reduction of hypoglycemia and increased time of glucose in target with a wearable artificial pancreas using modular model predictive control in adults with type 1 diabetes.
    Del Favero S; Place J; Kropff J; Messori M; Keith-Hynes P; Visentin R; Monaro M; Galasso S; Boscari F; Toffanin C; Di Palma F; Lanzola G; Scarpellini S; Farret A; Kovatchev B; Avogaro A; Bruttomesso D; Magni L; DeVries JH; Cobelli C; Renard E;
    Diabetes Obes Metab; 2015 May; 17(5):468-76. PubMed ID: 25600304
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: preliminary studies in Padova and Montpellier.
    Bruttomesso D; Farret A; Costa S; Marescotti MC; Vettore M; Avogaro A; Tiengo A; Dalla Man C; Place J; Facchinetti A; Guerra S; Magni L; De Nicolao G; Cobelli C; Renard E; Maran A
    J Diabetes Sci Technol; 2009 Sep; 3(5):1014-21. PubMed ID: 20144414
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Safety of outpatient closed-loop control: first randomized crossover trials of a wearable artificial pancreas.
    Kovatchev BP; Renard E; Cobelli C; Zisser HC; Keith-Hynes P; Anderson SM; Brown SA; Chernavvsky DR; Breton MD; Mize LB; Farret A; Place J; Bruttomesso D; Del Favero S; Boscari F; Galasso S; Avogaro A; Magni L; Di Palma F; Toffanin C; Messori M; Dassau E; Doyle FJ
    Diabetes Care; 2014 Jul; 37(7):1789-96. PubMed ID: 24929429
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Artificial pancreas using a personalized rule-based controller achieves overnight normoglycemia in patients with type 1 diabetes.
    Capel I; Rigla M; García-Sáez G; Rodríguez-Herrero A; Pons B; Subías D; García-García F; Gallach M; Aguilar M; Pérez-Gandía C; Gómez EJ; Caixàs A; Hernando ME
    Diabetes Technol Ther; 2014 Mar; 16(3):172-9. PubMed ID: 24152323
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multinational study of subcutaneous model-predictive closed-loop control in type 1 diabetes mellitus: summary of the results.
    Kovatchev B; Cobelli C; Renard E; Anderson S; Breton M; Patek S; Clarke W; Bruttomesso D; Maran A; Costa S; Avogaro A; Dalla Man C; Facchinetti A; Magni L; De Nicolao G; Place J; Farret A
    J Diabetes Sci Technol; 2010 Nov; 4(6):1374-81. PubMed ID: 21129332
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Day and night closed-loop control in adults with type 1 diabetes: a comparison of two closed-loop algorithms driving continuous subcutaneous insulin infusion versus patient self-management.
    Luijf YM; DeVries JH; Zwinderman K; Leelarathna L; Nodale M; Caldwell K; Kumareswaran K; Elleri D; Allen JM; Wilinska ME; Evans ML; Hovorka R; Doll W; Ellmerer M; Mader JK; Renard E; Place J; Farret A; Cobelli C; Del Favero S; Dalla Man C; Avogaro A; Bruttomesso D; Filippi A; Scotton R; Magni L; Lanzola G; Di Palma F; Soru P; Toffanin C; De Nicolao G; Arnolds S; Benesch C; Heinemann L;
    Diabetes Care; 2013 Dec; 36(12):3882-7. PubMed ID: 24170747
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Glucose-responsive insulin and glucagon delivery (dual-hormone artificial pancreas) in adults with type 1 diabetes: a randomized crossover controlled trial.
    Haidar A; Legault L; Dallaire M; Alkhateeb A; Coriati A; Messier V; Cheng P; Millette M; Boulet B; Rabasa-Lhoret R
    CMAJ; 2013 Mar; 185(4):297-305. PubMed ID: 23359039
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multinight "bedside" closed-loop control for patients with type 1 diabetes.
    Brown SA; Kovatchev BP; Breton MD; Anderson SM; Keith-Hynes P; Patek SD; Jiang B; Ben Brahim N; Vereshchetin P; Bruttomesso D; Avogaro A; Del Favero S; Boscari F; Galasso S; Visentin R; Monaro M; Cobelli C
    Diabetes Technol Ther; 2015 Mar; 17(3):203-9. PubMed ID: 25594434
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The "Glucositter" overnight automated closed loop system for type 1 diabetes: a randomized crossover trial.
    Nimri R; Danne T; Kordonouri O; Atlas E; Bratina N; Biester T; Avbelj M; Miller S; Muller I; Phillip M; Battelino T
    Pediatr Diabetes; 2013 May; 14(3):159-67. PubMed ID: 23448393
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evening and overnight closed-loop control versus 24/7 continuous closed-loop control for type 1 diabetes: a randomised crossover trial.
    Kovatchev BP; Kollar L; Anderson SM; Barnett C; Breton MD; Carr K; Gildersleeve R; Oliveri MC; Wakeman CA; Brown SA
    Lancet Digit Health; 2020 Feb; 2(2):e64-e73. PubMed ID: 32864597
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Randomized Controlled Trial of Mobile Closed-Loop Control.
    Kovatchev B; Anderson SM; Raghinaru D; Kudva YC; Laffel LM; Levy C; Pinsker JE; Wadwa RP; Buckingham B; Doyle FJ; Brown SA; Church MM; Dadlani V; Dassau E; Ekhlaspour L; Forlenza GP; Isganaitis E; Lam DW; Lum J; Beck RW;
    Diabetes Care; 2020 Mar; 43(3):607-615. PubMed ID: 31937608
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Feasibility of Long-Term Closed-Loop Control: A Multicenter 6-Month Trial of 24/7 Automated Insulin Delivery.
    Kovatchev B; Cheng P; Anderson SM; Pinsker JE; Boscari F; Buckingham BA; Doyle FJ; Hood KK; Brown SA; Breton MD; Chernavvsky D; Bevier WC; Bradley PK; Bruttomesso D; Del Favero S; Calore R; Cobelli C; Avogaro A; Ly TT; Shanmugham S; Dassau E; Kollman C; Lum JW; Beck RW
    Diabetes Technol Ther; 2017 Jan; 19(1):18-24. PubMed ID: 27982707
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multinational Home Use of Closed-Loop Control Is Safe and Effective.
    Anderson SM; Raghinaru D; Pinsker JE; Boscari F; Renard E; Buckingham BA; Nimri R; Doyle FJ; Brown SA; Keith-Hynes P; Breton MD; Chernavvsky D; Bevier WC; Bradley PK; Bruttomesso D; Del Favero S; Calore R; Cobelli C; Avogaro A; Farret A; Place J; Ly TT; Shanmugham S; Phillip M; Dassau E; Dasanayake IS; Kollman C; Lum JW; Beck RW; Kovatchev B;
    Diabetes Care; 2016 Jul; 39(7):1143-50. PubMed ID: 27208316
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.
    Rodbard D
    Diabetes Technol Ther; 2017 Jun; 19(S3):S25-S37. PubMed ID: 28585879
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Overnight Closed-Loop Control Improves Glycemic Control in a Multicenter Study of Adults With Type 1 Diabetes.
    Brown SA; Breton MD; Anderson SM; Kollar L; Keith-Hynes P; Levy CJ; Lam DW; Levister C; Baysal N; Kudva YC; Basu A; Dadlani V; Hinshaw L; McCrady-Spitzer S; Bruttomesso D; Visentin R; Galasso S; Del Favero S; Leal Y; Boscari F; Avogaro A; Cobelli C; Kovatchev BP
    J Clin Endocrinol Metab; 2017 Oct; 102(10):3674-3682. PubMed ID: 28666360
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial.
    Haidar A; Legault L; Messier V; Mitre TM; Leroux C; Rabasa-Lhoret R
    Lancet Diabetes Endocrinol; 2015 Jan; 3(1):17-26. PubMed ID: 25434967
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Control to range for diabetes: functionality and modular architecture.
    Kovatchev B; Patek S; Dassau E; Doyle FJ; Magni L; De Nicolao G; Cobelli C;
    J Diabetes Sci Technol; 2009 Sep; 3(5):1058-65. PubMed ID: 20144419
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Safety, efficacy and glucose turnover of reduced prandial boluses during closed-loop therapy in adolescents with type 1 diabetes: a randomized clinical trial.
    Elleri D; Biagioni M; Allen JM; Kumareswaran K; Leelarathna L; Caldwell K; Nodale M; Wilinska ME; Haidar A; Calhoun P; Kollman C; Jackson NC; Umpleby AM; Acerini CL; Dunger DB; Hovorka R
    Diabetes Obes Metab; 2015 Dec; 17(12):1173-9. PubMed ID: 26257323
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Diabetes technology and treatments in the paediatric age group.
    Shalitin S; Peter Chase H
    Int J Clin Pract Suppl; 2011 Feb; (170):76-82. PubMed ID: 21323816
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.