BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

819 related articles for article (PubMed ID: 22688617)

  • 21. Computed Tomography Evaluation of Percutaneous Pedicle Screws Inserted during Minimally Invasive Transforaminal Lumbar Interbody Fusion: Long-term Follow-up Results of Screw Violation.
    Lee JC; Jang HD; Choi SW; Shin BJ
    Clin Orthop Surg; 2023 Feb; 15(1):92-100. PubMed ID: 36778999
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Stimulus-evoked electromyography testing of percutaneous pedicle screws for the detection of pedicle breaches: a clinical study of 409 screws in 93 patients.
    Wang MY; Pineiro G; Mummaneni PV
    J Neurosurg Spine; 2010 Nov; 13(5):600-5. PubMed ID: 21039151
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Accuracy of pedicle screw placement in the thoracic and lumbosacral spine using a conventional intraoperative fluoroscopy-guided technique: a national neurosurgical education and training center analysis of 1236 consecutive screws.
    Nevzati E; Marbacher S; Soleman J; Perrig WN; Diepers M; Khamis A; Fandino J
    World Neurosurg; 2014 Nov; 82(5):866-71.e1-2. PubMed ID: 24954252
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The accuracy and safety of fluoroscopically guided percutaneous pedicle screws in the lumbosacral junction and the lumbar spine: a review of 880 screws.
    Chiu CK; Kwan MK; Chan CY; Schaefer C; Hansen-Algenstaedt N
    Bone Joint J; 2015 Aug; 97-B(8):1111-7. PubMed ID: 26224830
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Intraoperative anteroposterior and oblique fluoroscopic views for detection of mediolateral pedicle screw misplacement in the lumbar spine: a randomized cadaveric study.
    Spirig JM; Fasser MR; Widmer J; Wanivenhaus F; Laux CJ; Farshad M; Passaplan C
    Spine J; 2024 Apr; 24(4):730-735. PubMed ID: 37871659
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of minimally invasive spine surgery using intraoperative computed tomography integrated navigation, fluoroscopy, and conventional open surgery for lumbar spondylolisthesis: a prospective registry-based cohort study.
    Wu MH; Dubey NK; Li YY; Lee CY; Cheng CC; Shi CS; Huang TJ
    Spine J; 2017 Aug; 17(8):1082-1090. PubMed ID: 28412560
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Does Navigation Improve Pedicle Screw Placement Accuracy? Comparison Between Navigated and Non-navigated Percutaneous and Open Fixations.
    Innocenzi G; Bistazzoni S; D'Ercole M; Cardarelli G; Ricciardi F
    Acta Neurochir Suppl; 2017; 124():289-295. PubMed ID: 28120086
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluating the safe zone for lumbar pedicle screws: are midline crossing screws indicative of pedicle breach?
    Tannoury T; Seo HH; Saade A; Chahine MN; Atallah B; Tannoury C
    Spine J; 2024 Apr; 24(4):617-624. PubMed ID: 37939920
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Safety and accuracy of robot-assisted versus fluoroscopy-guided pedicle screw insertion for degenerative diseases of the lumbar spine: a matched cohort comparison.
    Schatlo B; Molliqaj G; Cuvinciuc V; Kotowski M; Schaller K; Tessitore E
    J Neurosurg Spine; 2014 Jun; 20(6):636-43. PubMed ID: 24725180
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Safety and accuracy of freehand versus navigated C2 pars or pedicle screw placement.
    Hlubek RJ; Bohl MA; Cole TS; Morgan CD; Xu DS; Chang SW; Turner JD; Kakarla UK
    Spine J; 2018 Aug; 18(8):1374-1381. PubMed ID: 29253631
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Complication rates associated with open versus percutaneous pedicle screw instrumentation among patients undergoing minimally invasive interbody fusion for adult spinal deformity.
    Than KD; Mummaneni PV; Bridges KJ; Tran S; Park P; Chou D; La Marca F; Uribe JS; Vogel TD; Nunley PD; Eastlack RK; Anand N; Okonkwo DO; Kanter AS; Mundis GM
    Neurosurg Focus; 2017 Dec; 43(6):E7. PubMed ID: 29191098
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Accuracy of K-Wireless Insertion of Percutaneous Pedicle Screws Using Computer-Assisted Spinal Navigation: A Systematic Review and Single-Center Experience.
    O'Donohoe TJ; Dawes BH; Thien C; Wang YY
    World Neurosurg; 2020 Jun; 138():e267-e274. PubMed ID: 32105880
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Circumferential fusion: a comparative analysis between anterior lumbar interbody fusion with posterior pedicle screw fixation and transforaminal lumbar interbody fusion for L5-S1 isthmic spondylolisthesis.
    Tye EY; Tanenbaum JE; Alonso AS; Xiao R; Steinmetz MP; Mroz TE; Savage JW
    Spine J; 2018 Mar; 18(3):464-471. PubMed ID: 28821444
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Facet Joint Violation During Percutaneous Pedicle Screw Placement: A Comparison of Two Techniques.
    Tannous O; Jazini E; Weir TB; Banagan KE; Koh EY; Greg Anderson D; Gelb DE; Ludwig SC
    Spine (Phila Pa 1976); 2017 Aug; 42(15):1189-1194. PubMed ID: 27922578
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Application of different thresholds for instrumentation device testing in minimally invasive lumbosacral spine fixation.
    Wu Y; Cohen D; Tellez MJ; DiGiacinto GV; Barquero AV; Ulkatan S
    J Clin Neurosci; 2020 Feb; 72():224-228. PubMed ID: 31866354
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models.
    Austin MS; Vaccaro AR; Brislin B; Nachwalter R; Hilibrand AS; Albert TJ
    Spine (Phila Pa 1976); 2002 Nov; 27(22):2503-8. PubMed ID: 12435982
    [TBL] [Abstract][Full Text] [Related]  

  • 37. How safe is minimally invasive pedicle screw placement for treatment of thoracolumbar spine fractures?
    Heintel TM; Dannigkeit S; Fenwick A; Jordan MC; Jansen H; Gilbert F; Meffert R
    Eur Spine J; 2017 May; 26(5):1515-1524. PubMed ID: 27933475
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Accuracy and technical limits of percutaneous pedicle screw placement in the thoracolumbar spine.
    Charles YP; Ntilikina Y; Collinet A; Schuller S; Garnon J; Godet J; Clavert P
    Surg Radiol Anat; 2021 Jun; 43(6):843-853. PubMed ID: 33449140
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of novel machine vision spinal image guidance system with existing 3D fluoroscopy-based navigation system: a randomized prospective study.
    Malham GM; Munday NR
    Spine J; 2022 Apr; 22(4):561-569. PubMed ID: 34666179
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Robotic versus fluoroscopy-guided pedicle screw insertion for metastatic spinal disease: a matched-cohort comparison.
    Solomiichuk V; Fleischhammer J; Molliqaj G; Warda J; Alaid A; von Eckardstein K; Schaller K; Tessitore E; Rohde V; Schatlo B
    Neurosurg Focus; 2017 May; 42(5):E13. PubMed ID: 28463620
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 41.