These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 22689010)

  • 1. Fabrication and evaluation of SixNy coatings for total joint replacements.
    Olofsson J; Pettersson M; Teuscher N; Heilmann A; Larsson K; Grandfield K; Persson C; Jacobson S; Engqvist H
    J Mater Sci Mater Med; 2012 Aug; 23(8):1879-89. PubMed ID: 22689010
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mechanical and tribological behavior of silicon nitride and silicon carbon nitride coatings for total joint replacements.
    Pettersson M; Tkachenko S; Schmidt S; Berlind T; Jacobson S; Hultman L; Engqvist H; Persson C
    J Mech Behav Biomed Mater; 2013 Sep; 25():41-7. PubMed ID: 23726925
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Preliminary tribological evaluation of nanostructured diamond coatings against ultra-high molecular weight polyethylene.
    Hill MR; Catledge SA; Konovalov V; Clem WC; Chowdhury SA; Etheridge BS; Stanishevsky A; Lemons JE; Vohra YK; Eberhardt AW
    J Biomed Mater Res B Appl Biomater; 2008 Apr; 85(1):140-8. PubMed ID: 17853416
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The counterface, surface smoothness, tolerances, and coatings in total joint prostheses.
    Santavirta SS; Lappalainen R; Pekko P; Anttila A; Konttinen YT
    Clin Orthop Relat Res; 1999 Dec; (369):92-102. PubMed ID: 10611864
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dissolution behaviour of silicon nitride coatings for joint replacements.
    Pettersson M; Bryant M; Schmidt S; Engqvist H; Hall RM; Neville A; Persson C
    Mater Sci Eng C Mater Biol Appl; 2016 May; 62():497-505. PubMed ID: 26952452
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Tribological characterization of zirconia coatings deposited on Ti6Al4V components for orthopedic applications.
    Berni M; Lopomo N; Marchiori G; Gambardella A; Boi M; Bianchi M; Visani A; Pavan P; Russo A; Marcacci M
    Mater Sci Eng C Mater Biol Appl; 2016 May; 62():643-55. PubMed ID: 26952468
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An in vitro study of the reduction in wear of metal-on-metal hip prostheses using surface-engineered femoral heads.
    Fisher J; Hu XQ; Tipper JL; Stewart TD; Williams S; Stone MH; Davies C; Hatto P; Bolton J; Riley M; Hardaker C; Isaac GH; Berry G; Ingham E
    Proc Inst Mech Eng H; 2002; 216(4):219-30. PubMed ID: 12206518
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements.
    Williams S; Tipper JL; Ingham E; Stone MH; Fisher J
    Proc Inst Mech Eng H; 2003; 217(3):155-63. PubMed ID: 12807156
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of aqueous solution and load on the formation of DLC transfer layer against Co-Cr-Mo for joint prosthesis.
    Guo F; Zhou Z; Hua M; Dong G
    J Mech Behav Biomed Mater; 2015 Sep; 49():12-22. PubMed ID: 25967039
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of silicon nitride as a wear resistant and resorbable alternative for total hip joint replacement.
    Olofsson J; Grehk TM; Berlind T; Persson C; Jacobson S; Engqvist H
    Biomatter; 2012; 2(2):94-102. PubMed ID: 23507807
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Nanostructured ceramics for biomedical implants.
    Catledge SA; Fries MD; Vohra YK; Lacefield WR; Lemons JE; Woodard S; Venugopalan R
    J Nanosci Nanotechnol; 2002; 2(3-4):293-312. PubMed ID: 12908255
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sliding properties of plasma assisted CVD CNchi coatings for metal bioimplants.
    Konvickova S; Cerny F; Gurovic J; Kvasnicka I; Suchanek J; Hnatowicz V
    Biomed Mater Eng; 2000; 10(1):13-7. PubMed ID: 10950203
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of superlattice CrN/NbN coatings for joint replacements deposited by high power impulse magnetron sputtering.
    Hovsepian PE; Ehiasarian AP; Purandare Y; Sugumaran AA; Marriott T; Khan I
    J Mater Sci Mater Med; 2016 Sep; 27(9):147. PubMed ID: 27571960
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multifunctional composite coating as a wear-resistant layer for the bearing in total hip joint replacement.
    Cho SM; Park JW; Han HS; Seok HK; Moon MW; Kim YC
    ACS Appl Mater Interfaces; 2013 Jan; 5(2):395-403. PubMed ID: 23249257
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hybrid diffusive/PVD treatments to improve the tribological resistance of Ti-6Al-4V.
    Marin E; Offoiach R; Lanzutti A; Regis M; Fusi S; Fedrizzi L
    Biomed Mater Eng; 2014; 24(1):581-92. PubMed ID: 24211942
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biotribological behavior of Ag-ZrCxN1-x coatings against UHMWPE for joint prostheses devices.
    Calderon V S; Sánchez-López JC; Cavaleiro A; Carvalho S
    J Mech Behav Biomed Mater; 2015 Jan; 41():83-91. PubMed ID: 25460405
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Wear and friction properties of experimental Ti-Si-Zr alloys for biomedical applications.
    Tkachenko S; Datskevich O; Kulak L; Jacobson S; Engqvist H; Persson C
    J Mech Behav Biomed Mater; 2014 Nov; 39():61-72. PubMed ID: 25105238
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biocompatibility and mechanical properties of diamond-like coatings on cobalt-chromium-molybdenum steel and titanium-aluminum-vanadium biomedical alloys.
    Hinüber C; Kleemann C; Friederichs RJ; Haubold L; Scheibe HJ; Schuelke T; Boehlert C; Baumann MJ
    J Biomed Mater Res A; 2010 Nov; 95(2):388-400. PubMed ID: 20648536
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Characteristics of different cathodic arc deposition coatings on CoCrMo for biomedical applications.
    Döring J; Crackau M; Nestler C; Welzel F; Bertrand J; Lohmann CH
    J Mech Behav Biomed Mater; 2019 Sep; 97():212-221. PubMed ID: 31129165
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Understanding the differences between the wear of metal-on-metal and ceramic-on-metal total hip replacements.
    Figueiredo-Pina CG; Yan Y; Neville A; Fisher J
    Proc Inst Mech Eng H; 2008 Apr; 222(3):285-96. PubMed ID: 18491698
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.