These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

330 related articles for article (PubMed ID: 22702252)

  • 1. Meeting an unmet need in glaucoma: continuous 24-h monitoring of intraocular pressure.
    Mansouri K; Weinreb RN
    Expert Rev Med Devices; 2012 May; 9(3):225-31. PubMed ID: 22702252
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Continuous 24-hour intraocular pressure monitoring for glaucoma--time for a paradigm change.
    Mansouri K; Weinreb R
    Swiss Med Wkly; 2012; 142():w13545. PubMed ID: 22457163
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Advances in telemetric continuous intraocular pressure assessment.
    Kakaday T; Hewitt AW; Voelcker NH; Li JS; Craig JE
    Br J Ophthalmol; 2009 Aug; 93(8):992-6. PubMed ID: 19244268
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pathophysiology of glaucoma and continuous measurements of intraocular pressure.
    Sit AJ; Liu JH
    Mol Cell Biomech; 2009 Mar; 6(1):57-69. PubMed ID: 19382536
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Implantation of a novel telemetric intraocular pressure sensor in patients with glaucoma (ARGOS study): 1-year results.
    Koutsonas A; Walter P; Roessler G; Plange N
    Invest Ophthalmol Vis Sci; 2015 Jan; 56(2):1063-9. PubMed ID: 25613949
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Continuous IOP fluctuation recording in normal tension glaucoma patients.
    Pajic B; Pajic-Eggspuchler B; Haefliger I
    Curr Eye Res; 2011 Dec; 36(12):1129-38. PubMed ID: 21978205
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Systematic Review of Current Devices for 24-h Intraocular Pressure Monitoring.
    Ittoop SM; SooHoo JR; Seibold LK; Mansouri K; Kahook MY
    Adv Ther; 2016 Oct; 33(10):1679-1690. PubMed ID: 27531519
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Fluctuation of intraocular pressure in 24-hour telemonitoring compared to tonometry during normal office hours].
    Jürgens C; Antal S; Henrici K; Grossjohann R; Tost FH
    Klin Monbl Augenheilkd; 2009 Jan; 226(1):54-9. PubMed ID: 19173164
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of repeated applanation tonometry on the accuracy of intraocular pressure measurements.
    Gaton DD; Ehrenberg M; Lusky M; Wussuki-Lior O; Dotan G; Weinberger D; Snir M
    Curr Eye Res; 2010 Jun; 35(6):475-9. PubMed ID: 20465440
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma.
    Mansouri K; Shaarawy T
    Br J Ophthalmol; 2011 May; 95(5):627-9. PubMed ID: 21216796
    [TBL] [Abstract][Full Text] [Related]  

  • 11. 24-hour Intraocular pressure monitoring: the way ahead.
    Bhartiya S; Gangwani M; Kalra RB; Aggarwal A; Gagrani M; Sirish KN
    Rom J Ophthalmol; 2019; 63(4):315-320. PubMed ID: 31915728
    [No Abstract]   [Full Text] [Related]  

  • 12. Continuous monitoring of intraocular pressure: rationale and progress toward a clinical device.
    Sit AJ
    J Glaucoma; 2009; 18(4):272-9. PubMed ID: 19365190
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Soft wearable contact lens sensor for continuous intraocular pressure monitoring.
    Chen GZ; Chan IS; Leung LK; Lam DC
    Med Eng Phys; 2014 Sep; 36(9):1134-9. PubMed ID: 25034639
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Continuous intraocular pressure (IOP) measurement during glaucoma drainage device implantation.
    Gouws P; Moss EB; Trope GE; Ethier CR
    J Glaucoma; 2007 May; 16(3):329-33. PubMed ID: 17438429
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Intraocular pressure difference in Goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01"PRA" in glaucoma patients].
    Schlote T; Landenberger H
    Klin Monbl Augenheilkd; 2005 Feb; 222(2):123-31. PubMed ID: 15719316
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Intraocular pressure measurements with the Proview self-tonometer in comparison of Goldmann applanation tonometry in healthy and glaucomatous eyes].
    Meyer MW; Yevelenko V; Hoy L; Meyer A; Erb C
    Klin Monbl Augenheilkd; 2006 Nov; 223(11):899-903. PubMed ID: 17131250
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Long-term follow-up after implantation of a telemetric intraocular pressure sensor in patients with glaucoma: a safety report.
    Koutsonas A; Walter P; Roessler G; Plange N
    Clin Exp Ophthalmol; 2018 Jul; 46(5):473-479. PubMed ID: 29136327
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of dynamic contour tonometry with Goldmann applanation tonometry in glaucoma practice.
    Halkiadakis I; Patsea E; Chatzimichali K; Skouriotis S; Chalkidou S; Amariotakis G; Papakonstadinou D; Theodossiadis G; Amariotakis A; Georgopoulos G
    Acta Ophthalmol; 2009 May; 87(3):323-8. PubMed ID: 18631335
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens.
    Lorenz K; Korb C; Herzog N; Vetter JM; Elflein H; Keilani MM; Pfeiffer N
    J Glaucoma; 2013; 22(4):311-6. PubMed ID: 23524857
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An overview of home tonometry and telemetry for intraocular pressure monitoring in humans.
    Yung E; Trubnik V; Katz LJ
    Graefes Arch Clin Exp Ophthalmol; 2014 Aug; 252(8):1179-88. PubMed ID: 24888380
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.