These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 22705890)

  • 1. Evaluation of a novel triple-channel radiochromic film analysis procedure using EBT2.
    van Hoof SJ; Granton PV; Landry G; Podesta M; Verhaegen F
    Phys Med Biol; 2012 Jul; 57(13):4353-68. PubMed ID: 22705890
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A dosimetry method in the transverse plane of HDR Ir-192 brachytherapy source using gafchromic EBT2 film.
    Uniyal SC; Sharma SD; Naithani UC
    Phys Med; 2012 Apr; 28(2):129-33. PubMed ID: 21507693
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An investigation of backscatter factors for kilovoltage x-rays: a comparison between Monte Carlo simulations and Gafchromic EBT film measurements.
    Kim J; Hill R; Claridge Mackonis E; Kuncic Z
    Phys Med Biol; 2010 Feb; 55(3):783-97. PubMed ID: 20071763
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison between radiochromic EBT2 film model and its predecessor EBT film model.
    Carrasco MA; Perucha M; Luis FJ; Baeza M; Herrador M
    Phys Med; 2013 Jun; 29(4):412-22. PubMed ID: 22738767
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Calibration of EBT2 film by the PDD method with scanner non-uniformity correction.
    Chang L; Chui CS; Ding HJ; Hwang IM; Ho SY
    Phys Med Biol; 2012 Sep; 57(18):5875-87. PubMed ID: 22951587
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Enhanced dosimetry procedures and assessment for EBT2 radiochromic film.
    Mayer RR; Ma F; Chen Y; Miller RI; Belard A; McDonough J; O'Connell JJ
    Med Phys; 2012 Apr; 39(4):2147-55. PubMed ID: 22482635
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multichannel film dosimetry with nonuniformity correction.
    Micke A; Lewis DF; Yu X
    Med Phys; 2011 May; 38(5):2523-34. PubMed ID: 21776787
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation and optimization of the new EBT2 radiochromic film dosimetry system for patient dose verification in radiotherapy.
    Richley L; John AC; Coomber H; Fletcher S
    Phys Med Biol; 2010 May; 55(9):2601-17. PubMed ID: 20393235
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Radiochromic film calibration for low-energy seed brachytherapy dose measurement.
    Morrison H; Menon G; Sloboda RS
    Med Phys; 2014 Jul; 41(7):072101. PubMed ID: 24989396
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Gafchromic EBT2 film dosimetry in reflection mode with a novel plan-based calibration method.
    Mendez I; Hartman V; Hudej R; Strojnik A; Casar B
    Med Phys; 2013 Jan; 40(1):011720. PubMed ID: 23298090
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The performance of an optical cone-beam CT scanner adapted for radiochromic film dosimetry.
    Babic S; Jordan K
    Phys Med Biol; 2012 Nov; 57(21):N377-89. PubMed ID: 23073219
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Gafchromic EBT3 film dosimetry in electron beams - energy dependence and improved film read-out.
    Sipilä P; Ojala J; Kaijaluoto S; Jokelainen I; Kosunen A
    J Appl Clin Med Phys; 2016 Jan; 17(1):360-373. PubMed ID: 26894368
    [TBL] [Abstract][Full Text] [Related]  

  • 13. EPR dosimetry of radiotherapy photon beams in inhomogeneous media using alanine films.
    Osterås BH; Hole EO; Olsen DR; Malinen E
    Phys Med Biol; 2006 Dec; 51(24):6315-28. PubMed ID: 17148820
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correcting lateral response artifacts from flatbed scanners for radiochromic film dosimetry.
    Lewis D; Chan MF
    Med Phys; 2015 Jan; 42(1):416-29. PubMed ID: 25563282
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Homogeneity of Gafchromic EBT2 film.
    Hartmann B; Martisiková M; Jäkel O
    Med Phys; 2010 Apr; 37(4):1753-6. PubMed ID: 20443496
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dose distribution for endovascular brachytherapy using Ir-192 sources: comparison of Monte Carlo calculations with radiochromic film measurements.
    Sureka CS; Sunny CS; Subbaiah KV; Aruna P; Ganesan S
    Phys Med Biol; 2007 Jan; 52(2):525-37. PubMed ID: 17202631
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Energy dependence and dose response of Gafchromic EBT2 film over a wide range of photon, electron, and proton beam energies.
    Arjomandy B; Tailor R; Anand A; Sahoo N; Gillin M; Prado K; Vicic M
    Med Phys; 2010 May; 37(5):1942-7. PubMed ID: 20527528
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Advanced kernel methods vs. Monte Carlo-based dose calculation for high energy photon beams.
    Fotina I; Winkler P; Künzler T; Reiterer J; Simmat I; Georg D
    Radiother Oncol; 2009 Dec; 93(3):645-53. PubMed ID: 19926153
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Application of Gafchromic EBT2 film for intraoperative radiation therapy quality assurance.
    Robatjazi M; Mahdavi SR; Takavr A; Baghani HR
    Phys Med; 2015 May; 31(3):314-9. PubMed ID: 25703011
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry.
    Ferreira BC; Lopes MC; Capela M
    Phys Med Biol; 2009 Feb; 54(4):1073-85. PubMed ID: 19168937
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.