BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 22706260)

  • 1. Carryover can be a cause of false-positive results with the Beckman AccuTnI assay.
    Dimeski G; Jones B; Brown N
    Clin Chem Lab Med; 2012 Jan; 50(6):1135-6. PubMed ID: 22706260
    [No Abstract]   [Full Text] [Related]  

  • 2. Cardiac Troponin I carryover by very high patient samples still causes false-positive results on the Beckman Coulter AccuTnI + 3.
    Wilgen U; Pretorius CJ; Gould MJ; Ungerer JP
    Ann Clin Biochem; 2016 Jan; 53(Pt 1):177-9. PubMed ID: 26345181
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Is the new Beckman AccuTnI+3 assay capable of producing false-positive troponin I results?
    Dimeski G; Coogan M; Jones B; Brown N
    Clin Chem Lab Med; 2015 Mar; 53(4):e101-3. PubMed ID: 25257160
    [No Abstract]   [Full Text] [Related]  

  • 4. The BD Barricor blood collection tube is an acceptable and robust alternative to the PST for use with the Beckman AccuTnI+3 assay.
    Füzéry AK; Raizman JE; Goudreau BL; Moses K; Niemann K; Park J; Cembrowski GS
    Clin Biochem; 2017 Oct; 50(15):851-857. PubMed ID: 28583435
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evidence on the cause of false positive troponin I results with the Beckman AccuTnI method.
    Dimeski G
    Clin Chem Lab Med; 2011 Jun; 49(6):1079-80. PubMed ID: 21428855
    [No Abstract]   [Full Text] [Related]  

  • 6. Carryover does not affect results of Beckman Coulter highly-sensitive-AccuTnI assay on Access 2.
    Lippi G; Avanzini P; Musa R; Aloe R; Cervellin G
    Clin Chem Lab Med; 2013 Jul; 51(7):e141-3. PubMed ID: 23337056
    [No Abstract]   [Full Text] [Related]  

  • 7. A critical evaluation of the Beckman Coulter Access hsTnI: Analytical performance, reference interval and concordance.
    Pretorius CJ; Tate JR; Wilgen U; Cullen L; Ungerer JPJ
    Clin Biochem; 2018 May; 55():49-55. PubMed ID: 29524431
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Matrix and bilirubin interference for high-sensitivity cardiac troponin I.
    Simons J; Beach L; Clark L; Kavsak PA
    Clin Chim Acta; 2015 Mar; 442():49-51. PubMed ID: 25603408
    [No Abstract]   [Full Text] [Related]  

  • 9. [Analytical false-positive increases and cardiac troponin I: what is the best sample?].
    Grenier A
    Ann Biol Clin (Paris); 2009; 67(1):118-20. PubMed ID: 19278053
    [No Abstract]   [Full Text] [Related]  

  • 10. BD rapid serum tubes reduce false positive plasma troponin T results on the Roche Cobas e411 analyzer.
    Koch CD; Wockenfus AM; Saenger AK; Jaffe AS; Karon BS
    Clin Biochem; 2012 Jul; 45(10-11):842-4. PubMed ID: 22561083
    [TBL] [Abstract][Full Text] [Related]  

  • 11. False increases of troponin I attributable to incomplete separation of serum.
    Nosanchuk JS; Combs B; Abbott G
    Clin Chem; 1999 May; 45(5):714. PubMed ID: 10222366
    [No Abstract]   [Full Text] [Related]  

  • 12. Challenges in harmonizing integrated healthcare network laboratories: Multi-center evaluation of the AccuTnI+3 troponin assay.
    Greene DN; Holmes DT; Liang J; Kwong SL; Lorey TS; Petrie MS
    Clin Biochem; 2015 Mar; 48(4-5):268-74. PubMed ID: 25464016
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Interference in the creatine kinase assay: the "wave" phenomenon].
    Cohen S
    Ann Biol Clin (Paris); 2003; 61(3):328-31. PubMed ID: 12805011
    [No Abstract]   [Full Text] [Related]  

  • 14. Specimen-dependent effects on the apparent analytical quality in surveys of Nordic clinical chemistry laboratories.
    Solberg HE; Skrede S
    Scand J Clin Lab Invest Suppl; 1984; 172():159-62. PubMed ID: 6599516
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Doubt on prevention of false-positive results of cardiac troponin I by recentrifugation.
    Pfäfflin A
    Clin Chem Lab Med; 2009; 47(7):892-3. PubMed ID: 19575553
    [No Abstract]   [Full Text] [Related]  

  • 16. Prevention of preanalytical false-positive increases of cardiac troponin I on the Unicel DxI 800 analyzer.
    Hejl CG; Astier HT; Ramirez JM
    Clin Chem Lab Med; 2008; 46(12):1789-90. PubMed ID: 19055457
    [No Abstract]   [Full Text] [Related]  

  • 17. Mechanism of interference by hemolysis in immunoassays and requirements for sample quality.
    Wenk RE
    Clin Chem; 1998 Dec; 44(12):2554. PubMed ID: 9836730
    [No Abstract]   [Full Text] [Related]  

  • 18. Age, sex, and racial influences on the Beckman Coulter AccuTnI+3 99th percentile.
    Greene DN; Leong TK; Collinson PO; Kamer SM; Huang K; Lorey TS; Go AS
    Clin Chim Acta; 2015 Apr; 444():149-53. PubMed ID: 25684454
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Serum cardiac troponin I levels in pediatric sepsis/septic shock.
    Smith DL; Prodhan P
    Pediatr Crit Care Med; 2009 Jul; 10(4):534. PubMed ID: 19584645
    [No Abstract]   [Full Text] [Related]  

  • 20. Analytical factors to consider when assessing a high-sensitivity cardiac troponin I assay compared to a contemporary assay in clinical studies.
    Rezvanpour A; Shortt C; Clark L; Worster A; Kavsak PA
    Clin Chim Acta; 2014 Feb; 429():6-7. PubMed ID: 24269504
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.