These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 2270872)

  • 1. Determination of L-ascorbic acid in fruit and vegetable juices by flow injection with immobilised ascorbate oxidase.
    Greenway GM; Ongomo P
    Analyst; 1990 Oct; 115(10):1297-9. PubMed ID: 2270872
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of ascorbic acid with immobilized green zucchini ascorbate oxidase.
    Stevanato R; Avigliano L; Finazzi-Agrò A; Rigo A
    Anal Biochem; 1985 Sep; 149(2):537-42. PubMed ID: 4073508
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Flow injection system with chemiluminometric detection for enzymatic determination of ascorbic acid.
    Dãnet AF; Badea M; Aboul-Enein HY
    Luminescence; 2000; 15(5):305-9. PubMed ID: 11038488
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Portable micro method for quantitative determination of vitamin C in fruit and vegetable juices.
    Rymal KS
    J Assoc Off Anal Chem; 1983 May; 66(3):810-3. PubMed ID: 6863199
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fabrication of multiwalled carbon nanotubes/polyaniline modified Au electrode for ascorbic acid determination.
    Chauhan N; Narang J; Pundir CS
    Analyst; 2011 May; 136(9):1938-45. PubMed ID: 21416096
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and characterization of a FIA system for selective assay of L-ascorbic acid in food samples.
    Vig A; Igloi A; Adanyi N; Gyemant G; Csutoras C; Kiss A
    Bioprocess Biosyst Eng; 2010 Oct; 33(8):947-52. PubMed ID: 20224919
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automated enzyme packed-bed system for the determination of vitamin C in foodstuffs.
    Daily S; Armfield SJ; Haggett BG; Downs ME
    Analyst; 1991 Jun; 116(6):569-72. PubMed ID: 1928729
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Simplification of the dinitrophenylhydrazine method for the photometric determination of ascorbic acid and dehydroascorbic acid in fruit juices. I. Application to juice of black current (author's transl)].
    Schmidt K; Holfelder E
    Z Lebensm Unters Forsch; 1975 Apr; 157(4):217-20. PubMed ID: 1229712
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Spectrophotometric determination of ascorbic acid in canned fruit juices, cordials, and soft drinks with iron(III) and 1,10-phenanthroline as reagents.
    Lau OW; Luk SF
    J Assoc Off Anal Chem; 1987; 70(3):518-20. PubMed ID: 3610966
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of total vitamin C by ion exclusion chromatography with electrochemical detection.
    Kim HJ
    J Assoc Off Anal Chem; 1989; 72(4):681-6. PubMed ID: 2759999
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fluorimetric determination of total ascorbic acid by a stopped-flow mixing technique.
    Pérez-Ruiz T; Martínez-Lozano C; Tomás V; Fenoll J
    Analyst; 2001 Aug; 126(8):1436-9. PubMed ID: 11534621
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of total vitamin C in fruit juices and related products by liquid chromatography: interlaboratory study.
    Brause AR; Woollard DC; Indyk HE
    J AOAC Int; 2003; 86(2):367-74. PubMed ID: 12723920
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Covalent immobilization of ascorbate oxidase onto polycarbonate strip for L-ascorbic acid detection.
    Kannoujia DK; Kumar S; Nahar P
    J Biosci Bioeng; 2012 Oct; 114(4):402-4. PubMed ID: 22704813
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of ascorbic acid content of some fruit juices and wine by voltammetry performed at pt and carbon paste electrodes.
    Pisoschi AM; Pop A; Negulescu GP; Pisoschi A
    Molecules; 2011 Feb; 16(2):1349-65. PubMed ID: 21285920
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development and characterization of an ascorbate oxidase-based sensor-biosensor system for telemetric detection of AA and antioxidant capacity in fresh orange juice.
    Barberis A; Spissu Y; Bazzu G; Fadda A; Azara E; Sanna D; Schirra M; Serra PA
    Anal Chem; 2014 Sep; 86(17):8727-34. PubMed ID: 25088601
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A fluorescence "turn-on" sensor for ascorbic acid in fruit juice and beverage based on ascorbate oxidase-like activity of citric acid-derived carbon dots.
    Lin Z; Zeng Q; Yao W; Chen W; Cai C; Yang J; Lin X; Chen W
    Food Chem; 2024 Mar; 437(Pt 2):137928. PubMed ID: 37976784
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of ascorbic acid and isoascorbic acid by capillary zone electrophoresis: application to fruit juices and to a pharmaceutical formulation.
    Lin Ling B; Baeyens WR; Van Acker P; Dewaele C
    J Pharm Biomed Anal; 1992; 10(10-12):717-21. PubMed ID: 1298373
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Atomic absorption spectrometry for the automatic indirect determination of ascorbic acid based on-the reduction of manganese dioxide.
    Noroozifar M; Khorasani-Motlagh M; Akhavan K
    Anal Sci; 2005 Jun; 21(6):655-9. PubMed ID: 15984201
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ascorbate Oxidase-Based Amperometric Biosensor for l-Ascorbic Acid Determination in Beverages.
    Csiffáry G; Fűtő P; Adányi N; Kiss A
    Food Technol Biotechnol; 2016 Mar; 54(1):31-35. PubMed ID: 27904390
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Construction of an amperometric ascorbate biosensor using epoxy resin membrane bound Lagenaria siceraria fruit ascorbate oxidase.
    Pundir CS; Chauhan N; Jyoti
    Artif Cells Blood Substit Immobil Biotechnol; 2011 Jun; 39(3):177-84. PubMed ID: 21067286
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.