BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

641 related articles for article (PubMed ID: 22717828)

  • 1. Large femoral heads decrease the incidence of dislocation after total hip arthroplasty: a randomized controlled trial.
    Howie DW; Holubowycz OT; Middleton R;
    J Bone Joint Surg Am; 2012 Jun; 94(12):1095-102. PubMed ID: 22717828
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wear and Osteolysis of Highly Crosslinked Polyethylene at 10 to 14 Years: The Effect of Femoral Head Size.
    Lachiewicz PF; Soileau ES; Martell JM
    Clin Orthop Relat Res; 2016 Feb; 474(2):365-71. PubMed ID: 25903943
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Is There a Difference in Revision Risk Between Metal and Ceramic Heads on Highly Crosslinked Polyethylene Liners?
    Cafri G; Paxton EW; Love R; Bini SA; Kurtz SM
    Clin Orthop Relat Res; 2017 May; 475(5):1349-1355. PubMed ID: 27385222
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Large Metal Heads and Highly Cross-Linked Polyethylene Provide Low Wear and Complications at 5-13 Years.
    Lachiewicz PF; O'Dell JA; Martell JM
    J Arthroplasty; 2018 Jul; 33(7):2187-2191. PubMed ID: 29588121
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Could larger diameter of 4th generation ceramic bearing decrease the rate of dislocation after THA?
    Lee YK; Ha YC; Jo WL; Kim TY; Jung WH; Koo KH
    J Orthop Sci; 2016 May; 21(3):327-31. PubMed ID: 26876620
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dislocation rate after conversion from hip hemiarthroplasty to total hip arthroplasty.
    Sah AP; Estok DM
    J Bone Joint Surg Am; 2008 Mar; 90(3):506-16. PubMed ID: 18310700
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Comparative study on association between femoral head size and linear wear rate of highly cross-linked polyethylene liner].
    Guo S; Sun J; Zha G; Wei S; Lu Q
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Nov; 28(11):1333-7. PubMed ID: 25639045
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of femoral head size on metal-on-HXLPE hip arthroplasty outcome in a combined analysis of six national and regional registries.
    Allepuz A; Havelin L; Barber T; Sedrakyan A; Graves S; Bordini B; Hoeffel D; Cafri G; Paxton E
    J Bone Joint Surg Am; 2014 Dec; 96 Suppl 1(Suppl 1):12-8. PubMed ID: 25520414
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fixation, survival, and dislocation of jumbo acetabular components in revision hip arthroplasty.
    Lachiewicz PF; Soileau ES
    J Bone Joint Surg Am; 2013 Mar; 95(6):543-8. PubMed ID: 23515989
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison between 28 mm and 32 mm ceramic-on-ceramic bearings in total hip replacement.
    Lee YK; Ha YC; Koo KH
    Bone Joint J; 2014 Nov; 96-B(11):1459-63. PubMed ID: 25371457
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Are ceramic-on-ceramic bearings in total hip arthroplasty associated with reduced revision risk for late dislocation?
    Pitto RP; Garland M; Sedel L
    Clin Orthop Relat Res; 2015 Dec; 473(12):3790-5. PubMed ID: 26070775
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Highly cross-linked polyethylene decreases the rate of revision of total hip arthroplasty compared with conventional polyethylene at 13 years' follow-up.
    Hanna SA; Somerville L; McCalden RW; Naudie DD; MacDonald SJ
    Bone Joint J; 2016 Jan; 98-B(1):28-32. PubMed ID: 26733512
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Decreased dislocation after revision total hip arthroplasty using larger femoral head size and posterior capsular repair.
    Hummel MT; Malkani AL; Yakkanti MR; Baker DL
    J Arthroplasty; 2009 Sep; 24(6 Suppl):73-6. PubMed ID: 19577890
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cup size and risk of dislocation after primary total hip arthroplasty.
    Peter R; Lübbeke A; Stern R; Hoffmeyer P
    J Arthroplasty; 2011 Dec; 26(8):1305-9. PubMed ID: 21414747
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Prevention of prothesis dislocation after the revision of total hip arthroplasty].
    Li YJ; Zhang LC; Yang GJ; Zhang CC; Wang WL; Lin RX; Cai CY
    Zhongguo Gu Shang; 2008 Mar; 21(3):173-5. PubMed ID: 19105429
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial.
    McCalden RW; MacDonald SJ; Rorabeck CH; Bourne RB; Chess DG; Charron KD
    J Bone Joint Surg Am; 2009 Apr; 91(4):773-82. PubMed ID: 19339560
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Large diameter femoral heads on highly cross-linked polyethylene: minimum 3-year results.
    Geller JA; Malchau H; Bragdon C; Greene M; Harris WH; Freiberg AA
    Clin Orthop Relat Res; 2006 Jun; 447():53-9. PubMed ID: 16741475
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dislocation of primary total hip arthroplasty with 36 and 40-mm femoral heads.
    Lachiewicz PF; Soileau ES
    Clin Orthop Relat Res; 2006 Dec; 453():153-5. PubMed ID: 17006370
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reduced dislocation rates and excellent functional outcomes with large-diameter femoral heads.
    Stroh DA; Issa K; Johnson AJ; Delanois RE; Mont MA
    J Arthroplasty; 2013 Sep; 28(8):1415-20. PubMed ID: 23602233
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Oxinium modular femoral heads do not reduce polyethylene wear in cemented total hip arthroplasty at five years: a randomised trial of 120 hips using radiostereometric analysis.
    Jonsson BA; Kadar T; Havelin LI; Haugan K; Espehaug B; Indrekvam K; Furnes O; Hallan G
    Bone Joint J; 2015 Nov; 97-B(11):1463-9. PubMed ID: 26530646
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 33.