These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 22719061)

  • 1. Defibrillation testing can reveal 'concealed' lead fracture.
    Bun SS; Duytschaever M; Tavernier R
    Europace; 2013 Jan; 15(1):54. PubMed ID: 22719061
    [No Abstract]   [Full Text] [Related]  

  • 2. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture.
    Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y
    Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Lead fracture and free-wall perforation in a patient with an implantable cardioverter-defibrillator.
    Kwon O; Kang SH; Park HW; Choi SW; Kim SH; Kim KH; Jin ES; Nam GB
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e167-9. PubMed ID: 21070262
    [TBL] [Abstract][Full Text] [Related]  

  • 4. REEL syndrome.
    Dichtl W; Feuchtner GM
    Wien Klin Wochenschr; 2014 Oct; 126(19-20):597. PubMed ID: 25193484
    [No Abstract]   [Full Text] [Related]  

  • 5. Inappropriate implantable cardioverter defibrillator shocks in fractured Sprint Fidelis leads associated with 'appropriate' interrogation.
    Farwell D; Redpath C; Birnie D; Gollob M; Lemery R; Posan E; Green M
    Europace; 2008 Jun; 10(6):726-8. PubMed ID: 18456645
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Abdominal twitching due to inadequate stitching.
    Miller MA; Singh SM; Gomes JA
    Europace; 2009 Dec; 11(12):1688. PubMed ID: 19880403
    [No Abstract]   [Full Text] [Related]  

  • 7. [Multiple inappropriate defibrillator shocks due to insulation failure of a Biotronik Linox defibrillator lead with externalized conductor].
    Elfarra H; Moosdorf R; Rybinski L; Grimm W
    Herzschrittmacherther Elektrophysiol; 2016 Mar; 27(1):70-2. PubMed ID: 26848762
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Non-functional lead as a cause of detection disturbances in implantable cardioverter-defibrillator].
    Kempa M; Budrejko S; Nowakowski M; Królak T; Daniłowicz-Szymanowicz L; Raczak G
    Kardiol Pol; 2012; 70(10):1073-5. PubMed ID: 23080104
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biventricular implantable cardioverter defibrillator right ventricle pace-sense ring electrode failure: lead switch fix.
    Venkataraman G; Moore H; Karasik P; Singh S; Fletcher R
    Pacing Clin Electrophysiol; 2008 Jul; 31(7):899-903. PubMed ID: 18684289
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Inappropriate ICD discharges due to noise oversensing as the first sign of repetitive perforations of the right ventricular lead.
    Ueda-Tatsumoto A; Fukamizu S; Nishizaki M; Sakurada H; Hiraoka M
    Pacing Clin Electrophysiol; 2009 Nov; 32(11):1481-4. PubMed ID: 19712072
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Durata™ may not be Riata™ but only time will tell….
    Maytin M; Epstein LM
    Pacing Clin Electrophysiol; 2013 Sep; 36(9):1055-8. PubMed ID: 23952330
    [No Abstract]   [Full Text] [Related]  

  • 12. Electrical failure of an ICD lead due to a presumed insulation defect only diagnosed by a maximum output shock.
    Goldstein MA; Badri M; Kocovic D; Kowey PR
    Pacing Clin Electrophysiol; 2013 Sep; 36(9):1068-71. PubMed ID: 23731252
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Near-Fatal ICD Lead Dysfunction with Implications for ICD Testing.
    Wutzler A; Attanasio P; Haverkamp W; Blaschke F
    Pacing Clin Electrophysiol; 2016 Jan; 39(1):105-6. PubMed ID: 26519249
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Inappropriate Shocks in a Patient with Subcutaneous ICD and Transvenous Pacemaker: Is it as it Seems?
    Santucci LM; Saputo FA; Verticelli L; Tamburri I; Placidi S; Silvetti MS; Drago F
    Pacing Clin Electrophysiol; 2016 Aug; 39(8):873-5. PubMed ID: 27198130
    [No Abstract]   [Full Text] [Related]  

  • 15. An Isolated and Transient Lead Impedance Alert as the Sole Indicator of ICD System Failure.
    Whittaker-Axon S; Breitenstein A; Finlay M
    Pacing Clin Electrophysiol; 2016 Sep; 39(9):1022-5. PubMed ID: 27119619
    [No Abstract]   [Full Text] [Related]  

  • 16. Multiple high lead impedances in an implantable-cardioverter defibrillator system: what is the mechanism?
    Ho RT
    Pacing Clin Electrophysiol; 2013 Sep; 36(9):1173-5. PubMed ID: 23594162
    [No Abstract]   [Full Text] [Related]  

  • 17. Prevention of inappropriate ICD shocks due to lead insulation failure by continuous monitoring and automatic alert.
    Gelder RN; Gunderson BD
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e150-3. PubMed ID: 22309317
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Elevated defibrillation threshold despite programmable tilt, pulse width, or implant of subcutaneous coil: role of higher energy devices.
    Nageh MF
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e179-81. PubMed ID: 21208237
    [TBL] [Abstract][Full Text] [Related]  

  • 19. "Spontaneous Twiddler's" Syndrome: The Importance of the Device Shape.
    Gul EE; Boles U; Haseeb S; Glover B; Simpson C; Baranchuk A; Michael K
    Pacing Clin Electrophysiol; 2017 Mar; 40(3):326-329. PubMed ID: 27859379
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Strategy to eliminate inappropriate shocks secondary to T-wave oversensing in a biventricular ICD.
    Silver JS; Gray ME; John RM
    Pacing Clin Electrophysiol; 2009 Jan; 32(1):134-6. PubMed ID: 19140924
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.