133 related articles for article (PubMed ID: 22732322)
1. Optimization and comparison of balloon-based partial breast brachytherapy using a single source, a standard plan line source, and both forward and inverse planned multilumen techniques.
Eyre K; Whitney D; Mukesh M; Wilson C; Coles C
Brachytherapy; 2013; 12(2):107-13. PubMed ID: 22732322
[TBL] [Abstract][Full Text] [Related]
2. Dosimetric evaluation of multilumen intracavitary balloon applicator rotation in high-dose-rate brachytherapy for breast cancer.
Kim Y; Trombetta MG
J Appl Clin Med Phys; 2014 Jan; 15(1):4429. PubMed ID: 24423837
[TBL] [Abstract][Full Text] [Related]
3. Comparison of single and multiple dwell position methods in MammoSite high dose rate (HDR) brachytherapy planning.
Kim Y; Trombetta MG; Miften M
J Appl Clin Med Phys; 2010 May; 11(3):3235. PubMed ID: 20717093
[TBL] [Abstract][Full Text] [Related]
4. Contura Multi-Lumen Balloon breast brachytherapy catheter: comparative dosimetric findings of a phase 4 trial.
Arthur DW; Vicini FA; Todor DA; Julian TB; Cuttino LW; Mukhopadhyay ND
Int J Radiat Oncol Biol Phys; 2013 Jun; 86(2):264-9. PubMed ID: 23433798
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of HDR interstitial breast implants planned by conventional and optimized CT-based dosimetry systems with respect to dose homogeneity and conformality.
Major T; Fodor J; Takácsi-Nagy Z; Agoston P; Polgár C
Strahlenther Onkol; 2005 Feb; 181(2):89-96. PubMed ID: 15702297
[TBL] [Abstract][Full Text] [Related]
6. Demonstration of simulated annealing optimization for permanent breast seed implant treatment planning.
Roumeliotis M; Yates B; Watt E; Frederick A; Meyer T
Brachytherapy; 2018; 17(3):615-620. PubMed ID: 29396035
[TBL] [Abstract][Full Text] [Related]
7. Dosimetric comparison of (192)Ir high-dose-rate brachytherapy vs. 50 kV x-rays as techniques for breast intraoperative radiation therapy: conceptual development of image-guided intraoperative brachytherapy using a multilumen balloon applicator and in-room CT imaging.
Jones R; Libby B; Showalter SL; Brenin DR; Wilson DD; Schroen A; Morris M; Reardon KA; Morrison J; Showalter TN
Brachytherapy; 2014; 13(5):502-7. PubMed ID: 24933339
[TBL] [Abstract][Full Text] [Related]
8. Three dimensional intensity modulated brachytherapy (IMBT): dosimetry algorithm and inverse treatment planning.
Shi C; Guo B; Cheng CY; Esquivel C; Eng T; Papanikolaou N
Med Phys; 2010 Jul; 37(7):3725-37. PubMed ID: 20831080
[TBL] [Abstract][Full Text] [Related]
9. A fast inverse treatment planning strategy facilitating optimized catheter selection in image-guided high-dose-rate interstitial gynecologic brachytherapy.
Guthier CV; Damato AL; Hesser JW; Viswanathan AN; Cormack RA
Med Phys; 2017 Dec; 44(12):6117-6127. PubMed ID: 28921538
[TBL] [Abstract][Full Text] [Related]
10. Accelerated partial breast irradiation: a dosimetric comparison of three different techniques.
Weed DW; Edmundson GK; Vicini FA; Chen PY; Martinez AA
Brachytherapy; 2005; 4(2):121-9. PubMed ID: 15893265
[TBL] [Abstract][Full Text] [Related]
11. Modeling study for optimization of skin dose for partial breast irradiation using Xoft Axxent electronic brachytherapy applicator.
Hepel JT; Hiatt JR; Cardarelli GA; Wazer DE
Brachytherapy; 2010; 9(1):81-5. PubMed ID: 19850533
[TBL] [Abstract][Full Text] [Related]
12. Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy.
Poulin E; Fekete CA; Létourneau M; Fenster A; Pouliot J; Beaulieu L
Med Phys; 2013 Nov; 40(11):111724. PubMed ID: 24320432
[TBL] [Abstract][Full Text] [Related]
13. Dosimetric comparisons between high dose rate interstitial and MammoSite balloon brachytherapy for breast cancer.
Major T; Niehoff P; Kovács G; Fodor J; Polgár C
Radiother Oncol; 2006 Jun; 79(3):321-8. PubMed ID: 16730085
[TBL] [Abstract][Full Text] [Related]
14. Initial radiation experience evaluating early tolerance and toxicities in patients undergoing accelerated partial breast irradiation using the Contura Multi-Lumen Balloon breast brachytherapy catheter.
Brown S; McLaughlin M; Pope K; Haile K; Hughes L; Israel PZ
Brachytherapy; 2009; 8(2):227-233. PubMed ID: 19217353
[TBL] [Abstract][Full Text] [Related]
15. Comparison of planning techniques when air/fluid is present using the strut-adjusted volume implant (SAVI) for HDR-based accelerated partial breast irradiation.
Harmon JF; Rice BK
J Appl Clin Med Phys; 2013 Nov; 14(6):4442. PubMed ID: 24257287
[TBL] [Abstract][Full Text] [Related]
16. Dosimetric experience with 2 commercially available multilumen balloon-based brachytherapy to deliver accelerated partial-breast irradiation.
Fu W; Kim JO; Chen AS; Mehta K; Pucci P; Huq MS
Med Dosim; 2015; 40(3):195-200. PubMed ID: 25542786
[TBL] [Abstract][Full Text] [Related]
17. Comparative dosimetric findings using accelerated partial breast irradiation across five catheter subtypes.
Rana Z; Nasr NM; Ji H; Lorio V; Akbari S; Sebastian M; Martin M; Hong RL
Radiat Oncol; 2015 Jul; 10():160. PubMed ID: 26227388
[TBL] [Abstract][Full Text] [Related]
18. On the feasibility of treating to a 1.5 cm PTV with a commercial single-entry hybrid applicator in APBI breast brachytherapy.
Gifford KA; Nelson CL; Kirsner SM; Kisling KD; Ballo MT; Bloom ES
J Contemp Brachytherapy; 2012 Mar; 4(1):29-33. PubMed ID: 23346137
[TBL] [Abstract][Full Text] [Related]
19. Dosimetric comparison of inverse optimisation methods versus forward optimisation in HDR brachytherapy of breast, cervical and prostate cancer.
Fröhlich G; Geszti G; Vízkeleti J; Ágoston P; Polgár C; Major T
Strahlenther Onkol; 2019 Nov; 195(11):991-1000. PubMed ID: 31482321
[TBL] [Abstract][Full Text] [Related]
20. Negative effect of seroma on breast balloon brachytherapy dosimetry.
Bhatt AD; Barry PN; Sowards KT; Dragun AE
Pract Radiat Oncol; 2014; 4(1):e1-5. PubMed ID: 24621426
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]