These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

206 related articles for article (PubMed ID: 22734996)

  • 1. Successful treatment of early thrombosis of HeartWare left ventricular assist device with intraventricular thrombolytics.
    Kamouh A; John R; Eckman P
    Ann Thorac Surg; 2012 Jul; 94(1):281-3. PubMed ID: 22734996
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Management of HeartWare left ventricular assist device thrombosis using intracavitary thrombolytics.
    Kiernan MS; Pham DT; DeNofrio D; Kapur NK
    J Thorac Cardiovasc Surg; 2011 Sep; 142(3):712-4. PubMed ID: 21277594
    [No Abstract]   [Full Text] [Related]  

  • 3. Successful treatment of acute left ventricular assist device thrombosis and cardiogenic shock with intraventricular thrombolysis and a tandem heart.
    Agarwal R; Raina A; Lasorda DM; Moraca RJ; Bailey SH; Kanwar M; Sokos G; Murali S; Benza RL
    ASAIO J; 2015; 61(1):98-101. PubMed ID: 25248042
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Identification and Management of Pump Thrombus in the HeartWare Left Ventricular Assist Device System: A Novel Approach Using Log File Analysis.
    Jorde UP; Aaronson KD; Najjar SS; Pagani FD; Hayward C; Zimpfer D; Schlöglhofer T; Pham DT; Goldstein DJ; Leadley K; Chow MJ; Brown MC; Uriel N
    JACC Heart Fail; 2015 Nov; 3(11):849-56. PubMed ID: 26454842
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Direct thrombolytic therapy for intraventricular thrombosis in patients with the Jarvik 2000 left ventricular assist device.
    Delgado R; Frazier OH; Myers TJ; Gregoric ID; Robertson K; Shah NA; Kar B
    J Heart Lung Transplant; 2005 Feb; 24(2):231-3. PubMed ID: 15701444
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Device thrombosis in the HeartWare left ventricular assist device.
    Siddique A; Wrightson N; Macgowan GA; Schueler S
    Ann Thorac Surg; 2013 Apr; 95(4):1508. PubMed ID: 23522225
    [No Abstract]   [Full Text] [Related]  

  • 7. Conservative approaches for HeartWare ventricular assist device pump thrombosis may improve the outcome compared with immediate surgical approaches.
    Saeed D; Maxhera B; Albert A; Westenfeld R; Hoffmann T; Lichtenberg A
    Interact Cardiovasc Thorac Surg; 2016 Jul; 23(1):90-5. PubMed ID: 26993475
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thrombolytic therapy for thrombosis of continuous flow ventricular assist devices.
    Schlendorf K; Patel CB; Gehrig T; Kiefer TL; Felker GM; Hernandez AF; Blue LJ; Milano CA; Rogers JG
    J Card Fail; 2014 Feb; 20(2):91-7. PubMed ID: 24361803
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Systemic or Endoventricular Thrombolysis to Treat HeartWare Left Ventricle Assist Device Thrombosis: A Clinical Dilemma.
    Raffa GM; D'Ancona G; Sciacca S; Pietrosi A; Hernandez Baravoglia CM; Turrisi M; Romano G; Armaro A; Stringi V; Clemenza F; Pilato M
    Artif Organs; 2015 Jun; 39(6):526-9. PubMed ID: 25735566
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Successful fibrinolysis after acute left ventricular assist device thrombosis.
    Tschirkov A; Nikolov D; Tasheva I; Papantchev V
    J Heart Lung Transplant; 2007 May; 26(5):553-5. PubMed ID: 17449429
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy.
    John R; Kamdar F; Liao K; Colvin-Adams M; Boyle A; Joyce L
    Ann Thorac Surg; 2008 Oct; 86(4):1227-34; discussion 1234-5. PubMed ID: 18805167
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Post-cardiac transplant survival after support with a continuous-flow left ventricular assist device: impact of duration of left ventricular assist device support and other variables.
    John R; Pagani FD; Naka Y; Boyle A; Conte JV; Russell SD; Klodell CT; Milano CA; Rogers J; Farrar DJ; Frazier OH
    J Thorac Cardiovasc Surg; 2010 Jul; 140(1):174-81. PubMed ID: 20447659
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Treatment of thrombus formation associated with the MicroMed DeBakey VAD using recombinant tissue plasminogen activator.
    Rothenburger M; Wilhelm MJ; Hammel D; Schmidt C; Tjan TD; Böcker D; Scheld HH; Schmid C
    Circulation; 2002 Sep; 106(12 Suppl 1):I189-92. PubMed ID: 12354731
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Treatment of device thrombus in the HeartWare HVAD: Success and outcomes depend significantly on the initial treatment strategy.
    Stulak JM; Dunlay SM; Sharma S; Haglund NA; Davis MB; Cowger J; Shah P; Masood F; Aaronson KD; Pagani FD; Maltais S
    J Heart Lung Transplant; 2015 Dec; 34(12):1535-41. PubMed ID: 26681123
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Successful treatment of ventricular assist device associated ventricular thrombus with systemic tenecteplase.
    Hayes H; Dembo L; Larbalestier R; O'Driscoll G
    Heart Lung Circ; 2008 Jun; 17(3):253-5. PubMed ID: 17581787
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Medication management for left ventricular assist device thrombosis.
    Hohner E; Crow J; Moranville MP
    Am J Health Syst Pharm; 2015 Jul; 72(13):1104-13. PubMed ID: 26092961
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effective treatment with a new protocol using tissue-type plasminogen activator thrombolysis for pump thrombosis with the HVAD device.
    Schrage B; Grahn H; Wagner FM; Bernhardt A; Rybczynski M; Blankenberg S; Reichenspurner H; Barten MJ
    Eur Heart J Acute Cardiovasc Care; 2018 Dec; 7(8):766-770. PubMed ID: 28058856
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Postcardiac transplant survival in the current era in patients receiving continuous-flow left ventricular assist devices.
    Kamdar F; John R; Eckman P; Colvin-Adams M; Shumway SJ; Liao K
    J Thorac Cardiovasc Surg; 2013 Feb; 145(2):575-81. PubMed ID: 23321132
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Seven years' experience with the Pierce-Donachy ventricular assist device.
    Pennington DG; Kanter KR; McBride LR; Kaiser GC; Barner HB; Miller LW; Naunheim KS; Fiore AC; Willman V
    J Thorac Cardiovasc Surg; 1988 Dec; 96(6):901-11. PubMed ID: 3057290
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Design changes in continuous-flow left ventricular assist devices and life-threatening pump malfunctions.
    Soltani S; Kaufmann F; Vierecke J; Kretzschmar A; Hennig E; Stein J; Hetzer R; Krabatsch T; Potapov EV
    Eur J Cardiothorac Surg; 2015 Jun; 47(6):984-9. PubMed ID: 25209626
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.