BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 22735107)

  • 1. Robust suppression of nonstationary power-line interference in electrocardiogram signals.
    Li G; Zeng X; Zhou X; Zhou Y; Liu G; Zhou X
    Physiol Meas; 2012 Jul; 33(7):1151-69. PubMed ID: 22735107
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Power-line interference detection and suppression in ECG signal processing.
    Lin YD; Hu YH
    IEEE Trans Biomed Eng; 2008 Jan; 55(1):354-7. PubMed ID: 18232382
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Fixed-Lag Kalman Smoother to Filter Power Line Interference in Electrocardiogram Recordings.
    Warmerdam GJJ; Vullings R; Schmitt L; Van Laar JOEH; Bergmans JWM
    IEEE Trans Biomed Eng; 2017 Aug; 64(8):1852-1861. PubMed ID: 27845652
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Extended Kalman Filter-Based Power Line Interference Canceller for Electrocardiogram Signal.
    Tahir S; Raja MM; Razzaq N; Mirza A; Khan WZ; Kim SW; Zikria YB
    Big Data; 2022 Feb; 10(1):34-53. PubMed ID: 34264763
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Research of adaptive notch filter based on QRD-LS algorithm for power line interference in ECG].
    Wang S; Dong J; Guan X
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Oct; 25(5):1044-7. PubMed ID: 19024443
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Removal Algorithm of Power Line Interference in Electrocardiogram Based on Morphological Component Analysis and Ensemble Empirical Mode Decomposition].
    Zhao W; Xiao S; Zhang B; Huang X; You R
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2015 Dec; 32(6):1179-84. PubMed ID: 27079083
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Arrhythmia ECG noise reduction by ensemble empirical mode decomposition.
    Chang KM
    Sensors (Basel); 2010; 10(6):6063-80. PubMed ID: 22219702
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Elimination of power line interference from ECG signals using recurrent neural networks.
    Yue Qiu ; Feng Xiao ; Haibin Shen
    Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():2296-2299. PubMed ID: 29060356
    [TBL] [Abstract][Full Text] [Related]  

  • 9. ECG signal denoising via empirical wavelet transform.
    Singh O; Sunkaria RK
    Australas Phys Eng Sci Med; 2017 Mar; 40(1):219-229. PubMed ID: 28035635
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Powerline interference reduction in ECG signals using empirical wavelet transform and adaptive filtering.
    Singh O; Sunkaria RK
    J Med Eng Technol; 2015 Jan; 39(1):60-8. PubMed ID: 25412942
    [TBL] [Abstract][Full Text] [Related]  

  • 11. EMD-based 60-Hz noise filtering of the ECG.
    Nimunkar AJ; Tompkins WJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():1904-7. PubMed ID: 18002354
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Noncontact ECG recording system with real time capacitance measurement for motion artifact reduction.
    Torfs T; Chen YH; Kim H; Yazicioglu RF
    IEEE Trans Biomed Circuits Syst; 2014 Oct; 8(5):617-25. PubMed ID: 25314708
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An improved adaptive power line interference canceller for electrocardiography.
    Martens SM; Mischi M; Oei SG; Bergmans JW
    IEEE Trans Biomed Eng; 2006 Nov; 53(11):2220-31. PubMed ID: 17073327
    [TBL] [Abstract][Full Text] [Related]  

  • 14. PLI cancellation in ECG signal based on adaptive filter by using Wiener-Hopf equation for providing initial condition.
    Manosueb A; Koseeyaporn J; Wardkein P
    Comput Math Methods Med; 2014; 2014():471409. PubMed ID: 25147577
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Anisotropic median-diffusion for filtering noisy electrocardiogram signals.
    de Melo MA; Kim HY; Nicolosi DE
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():2562-5. PubMed ID: 19163226
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Meet the challenge of high-pass filter and ST-segment requirements with a DC-coupled digital electrocardiogram amplifier.
    Abächerli R; Schmid HJ
    J Electrocardiol; 2009; 42(6):574-9. PubMed ID: 19700169
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fetal ECG extraction from abdominal signals: a review on suppression of fundamental power line interference component and its harmonics.
    Ţarălungă DD; Ungureanu GM; Gussi I; Strungaru R; Wolf W
    Comput Math Methods Med; 2014; 2014():239060. PubMed ID: 24660020
    [TBL] [Abstract][Full Text] [Related]  

  • 18. What is inside the electrocardiograph?
    Gregg RE; Zhou SH; Lindauer JM; Helfenbein ED; Giuliano KK
    J Electrocardiol; 2008; 41(1):8-14. PubMed ID: 18191652
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Event-synchronous cancellation of the heart interference in biomedical signals.
    Strobach P; Abraham-Fuchs K; Härer W
    IEEE Trans Biomed Eng; 1994 Apr; 41(4):343-50. PubMed ID: 8063300
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Arithmetic for subtracting power line interference based on estimating sinusoidal parameters].
    Hu X; Wei W; Liu C; Han X
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2010 Dec; 27(6):1243-6. PubMed ID: 21374972
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.