These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 2273877)

  • 1. First-order model for the analysis of stump stresses for below-knee amputees.
    Winarski DJ; Pearson JR
    J Biomech Eng; 1990 Nov; 112(4):475-8. PubMed ID: 2273877
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Least-squares matrix correlations between stump stresses and prosthesis loads for below-knee amputees.
    Winarski DJ; Pearson JR
    J Biomech Eng; 1987 Aug; 109(3):238-46. PubMed ID: 3657112
    [TBL] [Abstract][Full Text] [Related]  

  • 3. 3D intersegmental knee loading in below-knee amputees across steady-state walking speeds.
    Fey NP; Neptune RR
    Clin Biomech (Bristol, Avon); 2012 May; 27(4):409-14. PubMed ID: 22138437
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Interface shear stresses during ambulation with a below-knee prosthetic limb.
    Sanders JE; Daly CH; Burgess EM
    J Rehabil Res Dev; 1992; 29(4):1-8. PubMed ID: 1432723
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Prognostic factors in prosthetic rehabilitation of bilateral dysvascular above-knee amputee: is the stump condition an influencing factor?
    Traballesi M; Porcacchia P; Averna T; Angioni C; Lubich S; Di Meo F; Brunelli S
    Eura Medicophys; 2007 Mar; 43(1):1-6. PubMed ID: 16955063
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical investigation of the pressure and shear stress on the trans-tibial stump with a prosthesis.
    Zhang M; Turner-Smith AR; Tanner A; Roberts VC
    Med Eng Phys; 1998 Apr; 20(3):188-98. PubMed ID: 9690489
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Resultant lower extremity joint moments in below-knee amputees during running stance.
    Miller DI
    J Biomech; 1987; 20(5):529-41. PubMed ID: 3611127
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Swedish knee-cage for stabilizing short below-knee stumps.
    Isakov E; Mizrahi J; Susak Z; Onna I
    Prosthet Orthot Int; 1992 Aug; 16(2):114-7. PubMed ID: 1408669
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Gait Analysis of Transfemoral Amputees: Errors in Inverse Dynamics Are Substantial and Depend on Prosthetic Design.
    Dumas R; Branemark R; Frossard L
    IEEE Trans Neural Syst Rehabil Eng; 2017 Jun; 25(6):679-685. PubMed ID: 28113632
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tolerance of early walking with total contact among below-knee amputees--a randomized test.
    Liedberg E; Hommerberg H; Persson BM
    Prosthet Orthot Int; 1983 Aug; 7(2):91-5. PubMed ID: 6622240
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Frictional action at lower limb/prosthetic socket interface.
    Zhang M; Turner-Smith AR; Roberts VC; Tanner A
    Med Eng Phys; 1996 Apr; 18(3):207-14. PubMed ID: 8718946
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Computer simulation for the prediction of stump loading in above-knee amputees.
    Ishai G; Bar A
    Med Biol Eng Comput; 1983 Mar; 21(2):186-90. PubMed ID: 6887994
    [No Abstract]   [Full Text] [Related]  

  • 13. Comparison of computational analysis with clinical measurement of stresses on a below-knee residual limb in a prosthetic socket [Medical Engineering & Physics 22 (2000):607-12].
    Paul JP
    Med Eng Phys; 2001 Sep; 23(7):519-20. PubMed ID: 11686125
    [No Abstract]   [Full Text] [Related]  

  • 14. Energy expenditure in below-knee amputees: correlation with stump length.
    Gonzalez EG; Corcoran PJ; Reyes RL
    Arch Phys Med Rehabil; 1974 Mar; 55(3):111-9. PubMed ID: 4817680
    [No Abstract]   [Full Text] [Related]  

  • 15. Assessment of amputee socket-stump-residual bone kinematics during strenuous activities using Dynamic Roentgen Stereogrammetric Analysis.
    Papaioannou G; Mitrogiannis C; Nianios G; Fiedler G
    J Biomech; 2010 Mar; 43(5):871-8. PubMed ID: 20047746
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Triaxial force transducer for investigating stresses at the stump/socket interface.
    Williams RB; Porter D; Roberts VC; Regan JF
    Med Biol Eng Comput; 1992 Jan; 30(1):89-96. PubMed ID: 1640761
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of early mobilization on unhealed dysvascular transtibial amputation stumps: a clinical trial.
    Vanross ER; Johnson S; Abbott CA
    Arch Phys Med Rehabil; 2009 Apr; 90(4):610-7. PubMed ID: 19345776
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Crural amputation stump by Pirogov's method and prosthesis in the invalids].
    Kondrashin NI; Sanin VG; Iusupov VK
    Ortop Travmatol Protez; 1975 Dec; (12):1-6. PubMed ID: 1226275
    [No Abstract]   [Full Text] [Related]  

  • 19. Roentgenological study of movements of the amputation stump within the prosthesis socket in below-knee amputees fitted with a PTB prosthesis.
    Erikson U; Lemperg R
    Acta Orthop Scand; 1969; 40(4):520-9. PubMed ID: 5372254
    [No Abstract]   [Full Text] [Related]  

  • 20. Pressure characteristics at the stump/socket interface in transtibial amputees using an adaptive prosthetic foot.
    Wolf SI; Alimusaj M; Fradet L; Siegel J; Braatz F
    Clin Biomech (Bristol, Avon); 2009 Dec; 24(10):860-5. PubMed ID: 19744755
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.