BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

234 related articles for article (PubMed ID: 2273963)

  • 1. [The effect of the primary and repeated use of dialyzers with different membranes on the degree of dialysis-induced leukopenia].
    Strokov AG; Baeva LB; Levitskiĭ ER
    Med Tekh; 1990; (5):16-8. PubMed ID: 2273963
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Does an alteration of dialyzer design and geometry affect biocompatibility parameters?
    Opatrný K; Krouzzecký A; Polanská K; Mares J; Tomsů M; Bowry SK; Vienken J
    Hemodial Int; 2006 Apr; 10(2):201-8. PubMed ID: 16623675
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Effect of re-utilization of cuprophan capillary dialysers with different liquids on their biocompatibility and effectiveness of elimination].
    Orłowski A; Szepietowski T
    Polim Med; 1992; 22(1-2):59-72. PubMed ID: 1461837
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Increased binding of beta-2-microglobulin to blood cells in dialysis patients treated with high-flux dialyzers compared with low-flux membranes contributed to reduced beta-2-microglobulin concentrations. Results of a cross-over study.
    Traut M; Haufe CC; Eismann U; Deppisch RM; Stein G; Wolf G
    Blood Purif; 2007; 25(5-6):432-40. PubMed ID: 17957097
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Vitamin E-bonded cellulose membrane and hemodialysis bioincompatibility: absence of an acute benefit on expression of leukocyte surface molecules.
    Dhondt A; Vanholder R; Glorieux G; Waterloos MA; De Smet R; Lesaffer G; Lameire N
    Am J Kidney Dis; 2000 Dec; 36(6):1140-6. PubMed ID: 11096038
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [A study of the Limulus amebocyte lysate-reactive substances flushed from cellulose hemodialysis membranes].
    Strokov AG; Baeva LB; Levitskiĭ ER; Tiagny-Riadno LI
    Urol Nefrol (Mosk); 1993; (3):41-4. PubMed ID: 7941162
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Complement activation and leucopenia on cellulosic haemodialyzers: influence of the membrane area and role of hydroxyl moieties.
    Goldman M; Lietaer N; Lambert P; Thayse C; Vanherweghem JL
    Life Support Syst; 1987; 5(4):317-22. PubMed ID: 3501504
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The influence of dialyzer geometry on blood coagulation and biocompatibility.
    Lins LE; Boberg U; Jacobson SH; Kjellstrand C; Ljungberg B; Skröder R
    Clin Nephrol; 1993 Nov; 40(5):281-5. PubMed ID: 8281717
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A study on hemodialysis leukopenia using various dialyzers.
    Shin J; Matsuo M; Shinko S; Fujita Y; Inoue S; Sakai R; Nishioka M
    J Dial; 1980; 4(1):51-62. PubMed ID: 7410678
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biocompatibility of different hemodialysis membranes: activation of complement and leukopenia.
    Wegmüller E; Montandon A; Nydegger U; Descoeudres C
    Int J Artif Organs; 1986 Mar; 9(2):85-92. PubMed ID: 3699914
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Leukopenia and hypoxemia. Unrelated effects of hemodialysis.
    Dumler F; Levin NW
    Arch Intern Med; 1979 Oct; 139(10):1103-6. PubMed ID: 485741
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical characterization of Dicea a new cellulose membrane for haemodialysis.
    Hoenich NA; Woffindin C; Cox PJ; Goldfinch M; Roberts SJ
    Clin Nephrol; 1997 Oct; 48(4):253-9. PubMed ID: 9352161
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Differences in bio-incompatibility among four biocompatible dialyzer membranes using in maintenance hemodialysis patients.
    Zhang DL; Liu J; Cui WY; Ji DY; Zhang Y; Liu WH
    Ren Fail; 2011; 33(7):682-91. PubMed ID: 21787159
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Effect of hemodialysis using cuprophan and polysulfone dialyzers on rosette tests, concentration of immunoglobulins and complement components in serum of patients with chronic renal failure].
    Starzyk J; Bartelik S; Sarnecka S
    Wiad Lek; 1994 Jul; 47(13-14):523-6. PubMed ID: 7716940
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Mechanisms of acute leukopenia in hemodialysis. Role of direct leukocyte and dialyzer membrane interaction].
    Pacitti A; Segoloni G; Triolo G; Tetta C; Messina M; Bussolino F; Camussi G; Ragni R; Martini PF; Coppo R; Vercellone A
    Minerva Nefrol; 1980; 27(4):651-3. PubMed ID: 7254693
    [No Abstract]   [Full Text] [Related]  

  • 16. Serum beta 2-microglobulin concentration in dialysis patients: importance of intrinsic renal function.
    McCarthy JT; Williams AW; Johnson WJ
    J Lab Clin Med; 1994 Apr; 123(4):495-505. PubMed ID: 8144998
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biocompatibility of dialysis membranes: a comparative study.
    Martin-Malo A; Castillo D; Castro M; Pérez R; Rios A; Jaraba M; Aljama P
    Nephrol Dial Transplant; 1991; 6 Suppl 2():55-8. PubMed ID: 1866069
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The past, present and future of the dialyzer.
    Mineshima M
    Contrib Nephrol; 2015; 185():8-14. PubMed ID: 26023010
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Automatic re-utilization of capillary dialysis].
    Szepietowski T; Uzar J
    Polim Med; 1989; 19(3-4):107-18. PubMed ID: 2641400
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biocompatibility aspects of dialyzer reprocessing: a comparison of 3 re-use methods and 3 membranes.
    Kuwahara T; Markert M; Wauters JP
    Clin Nephrol; 1989 Sep; 32(3):139-43. PubMed ID: 2791365
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.