These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
152 related articles for article (PubMed ID: 22740479)
1. A new derivatization method coupled with LC-MS/MS to enable baseline separation and quantification of dimethylarginines in human plasma from patients to receive on-pump CABG surgery. Hui Y; Wong M; Kim JO; Love J; Ansley DM; Chen DD Electrophoresis; 2012 Jul; 33(12):1911-20. PubMed ID: 22740479 [TBL] [Abstract][Full Text] [Related]
2. Quantification of L-arginine, asymmetric dimethylarginine and symmetric dimethylarginine in human plasma: a step improvement in precision by stable isotope dilution mass spectrometry. Martens-Lobenhoffer J; Bode-Böger SM J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Sep; 904():140-3. PubMed ID: 22884474 [TBL] [Abstract][Full Text] [Related]
3. Simultaneous determination of asymmetric and symmetric dimethylarginine, L-monomethylarginine, L-arginine, and L-homoarginine in biological samples using stable isotope dilution liquid chromatography tandem mass spectrometry. Davids M; Swieringa E; Palm F; Smith DE; Smulders YM; Scheffer PG; Blom HJ; Teerlink T J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Jul; 900():38-47. PubMed ID: 22682940 [TBL] [Abstract][Full Text] [Related]
4. A simple and robust LC-MS/MS method for quantification of free 3-nitrotyrosine in human plasma from patients receiving on-pump CABG surgery. Hui Y; Wong M; Zhao SS; Love JA; Ansley DM; Chen DD Electrophoresis; 2012 Feb; 33(4):697-704. PubMed ID: 22451063 [TBL] [Abstract][Full Text] [Related]
5. A novel mass spectrometry-based method for simultaneous determination of asymmetric and symmetric dimethylarginine, l-arginine and l-citrulline optimized for LC-MS-TOF and LC-MS/MS. Wiśniewski J; Fleszar MG; Piechowicz J; Krzystek-Korpacka M; Chachaj A; Szuba A; Lorenc-Kukula K; Masłowski L; Witkiewicz W; Gamian A Biomed Chromatogr; 2017 Nov; 31(11):. PubMed ID: 28436051 [TBL] [Abstract][Full Text] [Related]
6. Development and application of a LC-MS/MS method to quantify basal adenosine concentration in human plasma from patients undergoing on-pump CABG surgery. Hui Y; Zhao SS; Love JA; Ansley DM; Chen DD J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Feb; 885-886():30-6. PubMed ID: 22226467 [TBL] [Abstract][Full Text] [Related]
7. GC-MS and LC-MS/MS pilot studies on the guanidine (N Bollenbach A; Gambaryan S; Mindukshev I; Pich A; Tsikas D J Chromatogr B Analyt Technol Biomed Life Sci; 2020 Mar; 1141():122024. PubMed ID: 32062367 [TBL] [Abstract][Full Text] [Related]
8. Quantification of Arginine and Its Methylated Derivatives in Plasma by High-Performance Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS). Vicente FB; Vespa G; Miller A; Haymond S Methods Mol Biol; 2016; 1378():21-30. PubMed ID: 26602113 [TBL] [Abstract][Full Text] [Related]
9. Simultaneous quantitative determination of N(G),N(G)-dimethyl-L-arginine or asymmetric dimethylarginine and related pathway's metabolites in biological fluids by ultrahigh-performance liquid chromatography/electrospray ionization-tandem mass spectrometry. Di Gangi IM; Chiandetti L; Gucciardi A; Moret V; Naturale M; Giordano G Anal Chim Acta; 2010 Sep; 677(2):140-8. PubMed ID: 20837180 [TBL] [Abstract][Full Text] [Related]
10. High-throughput liquid chromatographic-tandem mass spectrometric determination of arginine and dimethylated arginine derivatives in human and mouse plasma. Schwedhelm E; Maas R; Tan-Andresen J; Schulze F; Riederer U; Böger RH J Chromatogr B Analyt Technol Biomed Life Sci; 2007 May; 851(1-2):211-9. PubMed ID: 17194630 [TBL] [Abstract][Full Text] [Related]
11. High-performance liquid chromatographic assay of asymmetric dimethylarginine, symmetric dimethylarginine, and arginine in human plasma by derivatization with naphthalene-2,3-dicarboxaldehyde. Marra M; Bonfigli AR; Testa R; Testa I; Gambini A; Coppa G Anal Biochem; 2003 Jul; 318(1):13-7. PubMed ID: 12782025 [TBL] [Abstract][Full Text] [Related]
12. A simple and fast liquid chromatography-tandem mass spectrometry method for measurement of underivatized L-arginine, symmetric dimethylarginine, and asymmetric dimethylarginine and establishment of the reference ranges. El-Khoury JM; Bunch DR; Reineks E; Jackson R; Steinle R; Wang S Anal Bioanal Chem; 2012 Jan; 402(2):771-9. PubMed ID: 22124751 [TBL] [Abstract][Full Text] [Related]
14. Stable-isotope dilution LC-MS/MS measurement of nitrite in human plasma after its conversion to S-nitrosoglutathione. Hanff E; Böhmer A; Jordan J; Tsikas D J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Nov; 970():44-52. PubMed ID: 25237784 [TBL] [Abstract][Full Text] [Related]
15. Increased (E)-4-hydroxy-2-nonenal and asymmetric dimethylarginine concentrations and decreased nitric oxide concentrations in the plasma of patients with major depression. Selley ML J Affect Disord; 2004 Jun; 80(2-3):249-56. PubMed ID: 15207938 [TBL] [Abstract][Full Text] [Related]
16. Rapid and simple one-step membrane extraction for the determination of 8-hydroxy-2'-deoxyguanosine in human plasma by a combination of on-line solid phase extraction and LC-MS/MS. Wang CJ; Yang NH; Chang CC; Liou SH; Lee HL J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Nov; 879(30):3538-43. PubMed ID: 21982910 [TBL] [Abstract][Full Text] [Related]
17. Simultaneous determination of L-arginine, asymmetric dimethylarginine, and symmetric dimethylarginine in the plasma of rodents with LC-MS/MS. Chae JW; Baek IH; Kang W; Kwon KI Arzneimittelforschung; 2011; 61(6):340-6. PubMed ID: 21827044 [TBL] [Abstract][Full Text] [Related]
18. Effects of coronary revascularization with or without cardiopulmonary bypass on plasma levels of asymmetric dimethylarginine. Cziráki A; Ajtay Z; Németh Á; Lenkey Z; Sulyok E; Szabados S; Alotti N; Martens-Lobenhoffer J; Szabó C; Bode-Böger SM Coron Artery Dis; 2011 Jun; 22(4):245-52. PubMed ID: 21383621 [TBL] [Abstract][Full Text] [Related]
19. Direct analysis of un-derivatized asymmetric dimethylarginine (ADMA) and L-arginine from plasma using mixed-mode ion-exchange liquid chromatography-tandem mass spectrometry. Bishop MJ; Crow B; Norton D; Paliakov E; George J; Bralley JA J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Nov; 859(2):164-9. PubMed ID: 17931984 [TBL] [Abstract][Full Text] [Related]
20. A diethylpyrocarbonate-based derivatization method for the LC-MS/MS measurement of plasma arginine and its chemically related metabolites and analogs. Sotgia S; Zinellu A; Paliogiannis P; Pinna GA; Mangoni AA; Milanesi L; Carru C Clin Chim Acta; 2019 May; 492():29-36. PubMed ID: 30731087 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]