These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 22742714)

  • 1. The impact of the type of derotation mechanism on the stiffness of the Ilizarov fixator.
    Morasiewicz P; Filipiak J; Konietzko M; Dragan S
    Acta Bioeng Biomech; 2012; 14(1):67-73. PubMed ID: 22742714
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Biomechanical properties of external Ilizarov fixator with hybrid implants system].
    Filipiak J; Morasiewicz L
    Chir Narzadow Ruchu Ortop Pol; 2005; 70(1):49-56. PubMed ID: 16021824
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mechanical performance of hybrid Ilizarov external fixator in comparison with Ilizarov circular external fixator.
    Yilmaz E; Belhan O; Karakurt L; Arslan N; Serin E
    Clin Biomech (Bristol, Avon); 2003 Jul; 18(6):518-22. PubMed ID: 12828901
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical aspects of lower limb torsional deformation correction with the Ilizarov external fixator.
    Morasiewicz P; Filipiak J; Krysztoforski K; Dragan S
    Ann Biomed Eng; 2014 Mar; 42(3):613-8. PubMed ID: 24030066
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mechanical performance of Ilizarov circular external fixators in comparison with other external fixators.
    Podolsky A; Chao EY
    Clin Orthop Relat Res; 1993 Aug; (293):61-70. PubMed ID: 8339510
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effects of different wire and screw combinations on the stiffness of a hybrid external fixator.
    Yang L; Saleeh M; Nayagam S
    Proc Inst Mech Eng H; 2000; 214(6):669-76. PubMed ID: 11201414
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparing the mechanical characteristics between leg lengthening using only an Ilizarov external fixator and leg lengthening over a nail using an external fixator manufactured in Vietnam.
    Van Nguyen L
    Eur J Orthop Surg Traumatol; 2024 Feb; 34(2):839-846. PubMed ID: 37740769
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A simple way to model wires used in ring fixators: analysis of the wire stiffness effect on overall fixator stiffness.
    Nikonovas A; Harrison AJ
    Proc Inst Mech Eng H; 2005; 219(1):31-42. PubMed ID: 15777055
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mechanical stress on tensioned wires at direct and indirect loading: a biomechanical study on the Ilizarov external fixator.
    Gessmann J; Jettkant B; Schildhauer TA; Seybold D
    Injury; 2011 Oct; 42(10):1107-11. PubMed ID: 21392761
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Mechanical behavior of Ilizarov ring fixators. Effect of frame parameters on stiffness and consequences for clinical use].
    Duda GN; Kassi JP; Hoffmann JE; Riedt R; Khodadadyan C; Raschke M
    Unfallchirurg; 2000 Oct; 103(10):839-45. PubMed ID: 11098743
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The impact of configuration of the Ilizarov fixator on its stiffness and the degree of loading of distraction rods.
    Martyniuk B; Morasiewicz P; Wudarczyk S; Dragan SF; Filipiak J
    Clin Biomech (Bristol, Avon); 2019 Mar; 63():79-84. PubMed ID: 30849649
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The use of a low-profile Ilizarov external fixator in the treatment of complex fractures and non-unions of the distal femur.
    Cavusoglu AT; Ozsoy MH; Dincel VE; Sakaogullari A; Basarir K; Ugurlu M
    Acta Orthop Belg; 2009 Apr; 75(2):209-18. PubMed ID: 19492560
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The influence of a weight-bearing platform on the mechanical behavior of two Ilizarov ring fixators: tensioned wires vs. half-pins.
    Gessmann J; Citak M; Jettkant B; Schildhauer TA; Seybold D
    J Orthop Surg Res; 2011 Dec; 6():61. PubMed ID: 22152699
    [TBL] [Abstract][Full Text] [Related]  

  • 14. What Are the Biomechanical Properties of the Taylor Spatial Frameā„¢?
    Henderson DJ; Rushbrook JL; Harwood PJ; Stewart TD
    Clin Orthop Relat Res; 2017 May; 475(5):1472-1482. PubMed ID: 27896679
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The stiffness characteristics of hybrid Ilizarov fixators.
    Baran O; Havitcioglu H; Tatari H; Cecen B
    J Biomech; 2008 Oct; 41(14):2960-3. PubMed ID: 18789446
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Stiffness characteristics and inter-fragmentary displacements with different hybrid external fixators.
    Yang L; Nayagam S; Saleh M
    Clin Biomech (Bristol, Avon); 2003 Feb; 18(2):166-72. PubMed ID: 12550816
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A biomechanical analysis of the Ilizarov external fixator.
    Fleming B; Paley D; Kristiansen T; Pope M
    Clin Orthop Relat Res; 1989 Apr; (241):95-105. PubMed ID: 2924484
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical estimation of ilizarov fixator axial stiffness based on wire and half pin contributions.
    Waanders NA; Lawton JN; Steen H; Goulet JA; Goldstein SA
    Bull Hosp Jt Dis; 1993-1995; 53(4):10-2. PubMed ID: 8829588
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reduction in wire tension caused by dynamic loading. An experimental Ilizarov frame study.
    La Russa V; Skallerud B; Klaksvik J; Foss OA
    J Biomech; 2011 May; 44(8):1454-8. PubMed ID: 21453923
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Rigidity of half-pins for the Ilizarov external fixator.
    Calhoun JH; Li F; Bauford WL; Lehman T; Ledbetter BR; Lowery R
    Bull Hosp Jt Dis; 1992; 52(1):21-6. PubMed ID: 1422438
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.