These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
161 related articles for article (PubMed ID: 22742995)
1. [Microsurgical venous automatic suture using double ring eversion system]. Bodin F; Ganeval A; Lutz JC; Zink S; Wilk A; Bruant-Rodier C Ann Chir Plast Esthet; 2012 Aug; 57(4):323-7. PubMed ID: 22742995 [TBL] [Abstract][Full Text] [Related]
2. [The ring-pin anastomosis technique. Long-term clinical experiences with the mechanical ring-pin system for microvascular anastomoses in reconstructive head and neck surgery ]. Röpke E; Berghaus A; Bloching M HNO; 2004 Feb; 52(2):121-4. PubMed ID: 14968313 [TBL] [Abstract][Full Text] [Related]
3. End-to-side venous anastomosis with an anastomotic coupling device for microvascular free-tissue transfer in head and neck reconstruction. Chernichenko N; Ross DA; Shin J; Sasaki CT; Ariyan S Laryngoscope; 2008 Dec; 118(12):2146-50. PubMed ID: 19029861 [TBL] [Abstract][Full Text] [Related]
4. Application of fibrin glue in microvascular anastomoses: comparative analysis with the conventional suture technique using a free flap model. Cho AB; Júnior RM Microsurgery; 2008; 28(5):367-74. PubMed ID: 18561266 [TBL] [Abstract][Full Text] [Related]
5. [Mechanical venous microanastomosis using a double ring eversion system in reconstructive surgery]. Prade V; Parrau G; Seguin P; Champin J; Alix T Rev Stomatol Chir Maxillofac Chir Orale; 2013 Nov; 114(5):299-303. PubMed ID: 23856034 [TBL] [Abstract][Full Text] [Related]
6. Clinical experience with a microvascular anastomotic device in head and neck reconstruction. DeLacure MD; Wong RS; Markowitz BL; Kobayashi MR; Ahn CY; Shedd DP; Spies AL; Loree TR; Shaw WW Am J Surg; 1995 Nov; 170(5):521-3. PubMed ID: 7485747 [TBL] [Abstract][Full Text] [Related]
7. Clinical experience of a microvascular venous coupler device in free tissue transfers. Chang KP; Lin SD; Lai CS Kaohsiung J Med Sci; 2007 Nov; 23(11):566-72. PubMed ID: 18055305 [TBL] [Abstract][Full Text] [Related]
8. A simple technique for introducing small diameter vessels into a coupler device. Murphy MP; Mc Inerney NM; Browne KM; Henry Caulfield R; Hanson RP Microsurgery; 2017 Sep; 37(6):728. PubMed ID: 28032653 [No Abstract] [Full Text] [Related]
9. [VCS microclip anastomosis on blood vessels of less than 2 millimeters in diameter. Preliminary experimental study in the rat]. Gerbault O; Arrouvel C; Servant JM; Revol M; Banzet P Ann Chir Plast Esthet; 1998 Feb; 43(1):27-39. PubMed ID: 9768090 [TBL] [Abstract][Full Text] [Related]
10. [Use of coupler for venous anastomoses in cervico-facial reconstruction. Retrospective study on 51 free flaps]. Vernier-Mosca M; Feuvrier D; Obert L; Mauvais O; Loisel F; Pluvy I Ann Chir Plast Esthet; 2020 Jun; 65(3):236-243. PubMed ID: 31353075 [TBL] [Abstract][Full Text] [Related]
11. Venous Thrombosis in Handsewn versus Coupled Venous Anastomoses in 857 Consecutive Breast Free Flaps. Kulkarni AR; Mehrara BJ; Pusic AL; Cordeiro PG; Matros E; McCarthy CM; Disa JJ J Reconstr Microsurg; 2016 Mar; 32(3):178-82. PubMed ID: 26372685 [TBL] [Abstract][Full Text] [Related]
12. Microsurgical reconstruction of the lower extremity using the 3M microvascular coupling device in venous anastomoses. Denk MJ; Longaker MT; Basner AL; Glat PM; Karp NS; Kasabian AK Ann Plast Surg; 1995 Dec; 35(6):601-6. PubMed ID: 8748342 [TBL] [Abstract][Full Text] [Related]
13. Comparative study of different combinations of microvascular anastomosis types in a rat vasospasm model: versatility of end-to-side venous anastomosis in free tissue transfer for extremity reconstruction. Miyamoto S; Takushima A; Okazaki M; Ohura N; Momosawa A; Harii K J Trauma; 2009 Mar; 66(3):831-4. PubMed ID: 19276761 [TBL] [Abstract][Full Text] [Related]
14. [Vascular microanastomosis by eversion and stapling using VCS forceps. Presentation of the technique and experimental evaluation of its reliability]. Lambert F; Couturaud B; Cruel T; Lecoin G; Cariou JL Ann Chir Plast Esthet; 1998 Feb; 43(1):14-26. PubMed ID: 9768089 [TBL] [Abstract][Full Text] [Related]
15. [Mechanical vascular clips with an automatic stapler in reconstructive microsurgery. Apropos of 16 clinical cases]. Cariou JL; Lambert F; Bey E; Bellavoir A Chirurgie; 1997; 122(10):511-4; discussion 515. PubMed ID: 9616897 [TBL] [Abstract][Full Text] [Related]
16. Coupling the venous anastomosis: safe and simple. de Bruijn HP; Marck KW Microsurgery; 1996; 17(7):414-6. PubMed ID: 9379891 [TBL] [Abstract][Full Text] [Related]
17. Mechanical analysis of end-to-end silk-sutured anastomosis for robot-assisted surgery. Liu Y; Wang S; Hu SJ; Qiu W Int J Med Robot; 2009 Dec; 5(4):444-51. PubMed ID: 19722292 [TBL] [Abstract][Full Text] [Related]
18. Use of the vascular closure staple clip applier for microvascular anastomosis in free-flap surgery. Cope C; Lee K; Stern H; Pennington D Plast Reconstr Surg; 2000 Jul; 106(1):107-10. PubMed ID: 10883621 [TBL] [Abstract][Full Text] [Related]
19. Lower extremity free flap reconstruction outcomes using venous coupler. Ducic I; Brown BJ; Rao SS Microsurgery; 2011 Jul; 31(5):360-4. PubMed ID: 21630333 [TBL] [Abstract][Full Text] [Related]
20. Venous thrombosis in coupled versus sutured microvascular anastomoses. Yap LH; Constantinides J; Butler CE Ann Plast Surg; 2006 Dec; 57(6):666-9. PubMed ID: 17122555 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]