BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1008 related articles for article (PubMed ID: 22753867)

  • 1. Prolonged implantable electrocardiographic monitoring indicates a high rate of misdiagnosis of epilepsy--REVISE study.
    Petkar S; Hamid T; Iddon P; Clifford A; Rice N; Claire R; McKee D; Curtis N; Cooper PN; Fitzpatrick AP
    Europace; 2012 Nov; 14(11):1653-60. PubMed ID: 22753867
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Additional diagnostic value of implantable loop recorder in patients with initial diagnosis of real or apparent transient loss of consciousness of uncertain origin.
    Maggi R; Rafanelli M; Ceccofiglio A; Solari D; Brignole M; Ungar A
    Europace; 2014 Aug; 16(8):1226-30. PubMed ID: 24668513
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Tilt table testing in patients with suspected epilepsy.
    Edfors R; Erdal J; A-Rogvi-Hansen B
    Acta Neurol Scand; 2008 May; 117(5):354-8. PubMed ID: 18081916
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Usefulness of head-up tilt test combined with video electroencephalogram to investigate recurrent unexplained atypical transient loss of consciousness.
    Ninni S; Kouakam C; Szurhaj W; Baille G; Klug D; Lacroix D; Derambure P
    Arch Cardiovasc Dis; 2019 Feb; 112(2):82-94. PubMed ID: 30600217
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Misdiagnosis of epilepsy: many seizure-like attacks have a cardiovascular cause.
    Zaidi A; Clough P; Cooper P; Scheepers B; Fitzpatrick AP
    J Am Coll Cardiol; 2000 Jul; 36(1):181-4. PubMed ID: 10898432
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The utility of implantable loop recorders for diagnosing unexplained syncope in 100 consecutive patients: five-year, single-center experience.
    Inamdar V; Mehta S; Juang G; Cohen T
    J Invasive Cardiol; 2006 Jul; 18(7):313-5. PubMed ID: 16816436
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Syncope or seizure? The diagnostic value of synchronous tilt testing and video-EEG monitoring in children with transient loss of consciousness.
    Yilmaz S; Gökben S; Levent E; Serdaroğlu G; Özyürek R
    Epilepsy Behav; 2012 May; 24(1):93-6. PubMed ID: 22459868
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Diagnosis of neurally mediated syncope at initial evaluation and with tilt table testing compared with that revealed by prolonged ECG monitoring. An analysis from the Third International Study on Syncope of Uncertain Etiology (ISSUE-3).
    Ungar A; Sgobino P; Russo V; Vitale E; Sutton R; Melissano D; Beiras X; Bottoni N; Ebert HH; Gulizia M; Jorfida M; Moya A; Andresen D; Grovale N; Brignole M;
    Heart; 2013 Dec; 99(24):1825-31. PubMed ID: 24153416
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Additional diagnostic value of very prolonged observation by implantable loop recorder in patients with unexplained syncope.
    Furukawa T; Maggi R; Bertolone C; Fontana D; Brignole M
    J Cardiovasc Electrophysiol; 2012 Jan; 23(1):67-71. PubMed ID: 21777327
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The benefit of a remotely monitored implantable loop recorder as a first line investigation in unexplained syncope: the EaSyAS II trial.
    Sulke N; Sugihara C; Hong P; Patel N; Freemantle N
    Europace; 2016 Jun; 18(6):912-8. PubMed ID: 26462702
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Over-interpretation of electroclinical and neuroimaging findings in syncopes misdiagnosed as epileptic seizures.
    Fattouch J; Di Bonaventura C; Strano S; Vanacore N; Manfredi M; Prencipe M; Giallonardo AT
    Epileptic Disord; 2007 Jun; 9(2):170-3. PubMed ID: 17525028
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical impact of the implantable loop recorder in patients with isolated syncope, bundle branch block and negative workup: a randomized multicentre prospective study.
    Da Costa A; Defaye P; Romeyer-Bouchard C; Roche F; Dauphinot V; Deharo JC; Jacon P; Lamaison D; Bathélemy JC; Isaaz K; Laurent G
    Arch Cardiovasc Dis; 2013 Mar; 106(3):146-54. PubMed ID: 23582676
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Lack of correlation between the responses to tilt testing and adenosine triphosphate test and the mechanism of spontaneous neurally mediated syncope.
    Brignole M; Sutton R; Menozzi C; Garcia-Civera R; Moya A; Wieling W; Andresen D; Benditt DG; Grovale N; De Santo T; Vardas P;
    Eur Heart J; 2006 Sep; 27(18):2232-9. PubMed ID: 16864606
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The usage and diagnostic yield of the implantable loop-recorder in detection of the mechanism of syncope and in guiding effective antiarrhythmic therapy in older people.
    Brignole M; Menozzi C; Maggi R; Solano A; Donateo P; Bottoni N; Lolli G; Quartieri F; Croci F; Oddone D; Puggioni E
    Europace; 2005 May; 7(3):273-9. PubMed ID: 15878567
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ictal asystole and ictal syncope: insights into clinical management.
    Bestawros M; Darbar D; Arain A; Abou-Khalil B; Plummer D; Dupont WD; Raj SR
    Circ Arrhythm Electrophysiol; 2015 Feb; 8(1):159-64. PubMed ID: 25391254
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Malignant vasovagal syncope].
    Halmai L; Avramov K; Rudas L
    Orv Hetil; 2003 Jun; 144(25):1235-9. PubMed ID: 12901179
    [TBL] [Abstract][Full Text] [Related]  

  • 17. How to Differentiate Syncope from Seizure.
    Sheldon R
    Cardiol Clin; 2015 Aug; 33(3):377-85. PubMed ID: 26115824
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Implantable loop recorder is an effective diagnostic tool for unexplained syncope.
    Bovin A; Malczynski J; Dalsgaard D
    Dan Med J; 2012 Oct; 59(10):A4518. PubMed ID: 23158894
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Usefulness of the head-upright tilt test for distinguishing syncope and epilepsy in children.
    Eirís-Puñal J; Rodríguez-Núñez A; Fernández-Martínez N; Fuster M; Castro-Gago M; Martinón JM
    Epilepsia; 2001 Jun; 42(6):709-13. PubMed ID: 11422323
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tilt table testing with video EEG monitoring in the evaluation of patients with unexplained loss of consciousness.
    LaRoche S; Taylor D; Walter P
    Clin EEG Neurosci; 2011 Jul; 42(3):202-5. PubMed ID: 21870474
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 51.