292 related articles for article (PubMed ID: 22755715)
1. Radiobiology for eye plaque brachytherapy and evaluation of implant duration and radionuclide choice using an objective function.
Gagne NL; Leonard KL; Rivard MJ
Med Phys; 2012 Jun; 39(6):3332-42. PubMed ID: 22755715
[TBL] [Abstract][Full Text] [Related]
2. SU-E-T-459: Radiobiological Evaluation of Implant Duration and Radionuclide Selection for COMS Eye Plaque Brachytherapy Using an Objective Function.
Gagne N; Rivard M
Med Phys; 2012 Jun; 39(6Part17):3810. PubMed ID: 28517460
[TBL] [Abstract][Full Text] [Related]
3. BEDVH-A method for evaluating biologically effective dose volume histograms: application to eye plaque brachytherapy implants.
Gagne NL; Leonard KL; Huber KE; Mignano JE; Duker JS; Laver NV; Rivard MJ
Med Phys; 2012 Feb; 39(2):976-83. PubMed ID: 22320806
[TBL] [Abstract][Full Text] [Related]
4. Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom.
Lesperance M; Inglis-Whalen M; Thomson RM
Med Phys; 2014 Feb; 41(2):021717. PubMed ID: 24506608
[TBL] [Abstract][Full Text] [Related]
5. Dosimetry of (125)I and (103)Pd COMS eye plaques for intraocular tumors: report of Task Group 129 by the AAPM and ABS.
Chiu-Tsao ST; Astrahan MA; Finger PT; Followill DS; Meigooni AS; Melhus CS; Mourtada F; Napolitano ME; Nath R; Rivard MJ; Rogers DW; Thomson RM
Med Phys; 2012 Oct; 39(10):6161-84. PubMed ID: 23039655
[TBL] [Abstract][Full Text] [Related]
6. Dosimetric and radiobiologic comparison of
Gorovets D; Gagne NL; Melhus CS
Brachytherapy; 2017; 16(2):433-443. PubMed ID: 28161431
[TBL] [Abstract][Full Text] [Related]
7. Quantifying the dosimetric influences of radiation coverage and brachytherapy implant placement uncertainty on eye plaque size selection.
Gagne NL; Rivard MJ
Brachytherapy; 2013; 12(5):508-20. PubMed ID: 23466357
[TBL] [Abstract][Full Text] [Related]
8. Monte Carlo dosimetry for 103Pd, 125I, and 131Cs ocular brachytherapy with various plaque models using an eye phantom.
Lesperance M; Martinov M; Thomson RM
Med Phys; 2014 Mar; 41(3):031706. PubMed ID: 24593710
[TBL] [Abstract][Full Text] [Related]
9. Monte Carlo dosimetry for 125I and 103Pd eye plaque brachytherapy.
Thomson RM; Taylor RE; Rogers DW
Med Phys; 2008 Dec; 35(12):5530-43. PubMed ID: 19175111
[TBL] [Abstract][Full Text] [Related]
10. EyeDose: An open-source tool for using published Monte Carlo results to estimate the radiation dose delivered to the tumor and critical ocular structures for
Deufel CL; McCauley Cutsinger S; Corbin KS; Dalvin LA; Petersen IA
Brachytherapy; 2021; 20(1):189-199. PubMed ID: 33187821
[TBL] [Abstract][Full Text] [Related]
11. A practical approach to estimating optic disc dose and macula dose without treatment planning in ocular brachytherapy using
Lee YC; Lin SC; Kim Y
Radiat Oncol; 2018 Nov; 13(1):221. PubMed ID: 30424782
[TBL] [Abstract][Full Text] [Related]
12. A comprehensive dosimetric comparison between (131)Cs and (125)I brachytherapy sources for COMS eye plaque implant.
Zhang H; Martin D; Chiu-Tsao ST; Meigooni A; Thomadsen BR
Brachytherapy; 2010; 9(4):362-72. PubMed ID: 20116342
[TBL] [Abstract][Full Text] [Related]
13. Delivered dose uncertainty analysis at the tumor apex for ocular brachytherapy.
Morrison H; Menon G; Larocque MP; Jans HS; Weis E; Sloboda RS
Med Phys; 2016 Aug; 43(8):4891. PubMed ID: 27487906
[TBL] [Abstract][Full Text] [Related]
14. Monte Carlo dosimetry for 125I and 103Pd eye plaque brachytherapy with various seed models.
Thomson RM; Rogers DW
Med Phys; 2010 Jan; 37(1):368-76. PubMed ID: 20175499
[TBL] [Abstract][Full Text] [Related]
15. COMS eye plaque brachytherapy dosimetric sensitivity to source photon energy and seed design.
Gagne NL; Rivard MJ
Appl Radiat Isot; 2013 Sep; 79():62-6. PubMed ID: 23728350
[TBL] [Abstract][Full Text] [Related]
16. 106Ru/106Rh plaque and proton radiotherapy for ocular melanoma: a comparative dosimetric study.
Mourtada F; Koch N; Newhauser W
Radiat Prot Dosimetry; 2005; 116(1-4 Pt 2):454-60. PubMed ID: 16604677
[TBL] [Abstract][Full Text] [Related]
17. The impact of prescription depth, dose rate, plaque size, and source loading on the central axis using 103Pd, 125I, and 131Cs.
Rivard MJ; Melhus CS; Sioshansi S; Morr J
Brachytherapy; 2008; 7(4):327-35. PubMed ID: 18782684
[TBL] [Abstract][Full Text] [Related]
18. Dosimetric comparison of circular Eye Physics and Collaborative Ocular Melanoma Study plaques to treat uveal melanoma.
Dean MK; Studenski MT; Paez-Escamilla MA; Walter SD; Kwon D; Markoe AM; Harbour JW; Samuels SE
Brachytherapy; 2019; 18(3):404-410. PubMed ID: 30797699
[TBL] [Abstract][Full Text] [Related]
19. Advanced Collapsed cone Engine dose calculations in tissue media for COMS eye plaques loaded with I-125 seeds.
Morrison H; Menon G; Larocque MP; van Veelen B; Niatsetski Y; Weis E; Sloboda RS
Med Phys; 2018 Jul; 45(7):3349-3360. PubMed ID: 29729009
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of material heterogeneity dosimetric effects using radiochromic film for COMS eye plaques loaded with (125)I seeds (model I25.S16).
Acar H; Chiu-Tsao ST; Ozbay I; Kemikler G; Tuncer S
Med Phys; 2013 Jan; 40(1):011708. PubMed ID: 23298078
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]