BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 22760954)

  • 1. The effect of pulmonary blood flow changes on oxygen-enhanced lung magnetic resonance imaging.
    Lee HJ; Park J; Hur J; Kim YJ; Nam JE; Choi BW; Choe KO
    Magn Reson Med; 2013 Jun; 69(6):1645-9. PubMed ID: 22760954
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of oxygen inhalation on the pulmonary circulation: assessment by magnetic resonance (MR)-perfusion and MR-flow measurements.
    Ley S; Puderbach M; Risse F; Ley-Zaporozhan J; Eichinger M; Takenaka D; Kauczor HU; Bock M
    Invest Radiol; 2007 May; 42(5):283-90. PubMed ID: 17414523
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influences of prolonged apnea and oxygen inhalation on pulmonary hemodynamics during breath holding: quantitative assessment by velocity-encoded MR imaging with SENSE technique.
    Nogami M; Ohno Y; Higashino T; Takenaka D; Yoshikawa T; Koyama H; Kawamitsu H; Fujii M; Sugimura K
    Eur J Radiol; 2007 Dec; 64(3):375-80. PubMed ID: 17904323
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of oxygen flow rate on signal and T(1) changes in oxygen-enhanced ventilation imaging.
    Mai VM; Liu B; Li W; Polzin J; Kurucay S; Chen Q; Edelman RR
    J Magn Reson Imaging; 2002 Jul; 16(1):37-41. PubMed ID: 12112501
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dual-bolus approach to quantitative measurement of pulmonary perfusion by contrast-enhanced MRI.
    Risse F; Semmler W; Kauczor HU; Fink C
    J Magn Reson Imaging; 2006 Dec; 24(6):1284-90. PubMed ID: 17051533
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improvement of multislice oxygen-enhanced MRI of the lung by fully automatic non-rigid image registration.
    Molinari F; Bauman G; Paolantonio G; Geisler T; Geiger B; Bonomo L; Kauczor HU; Puderbach M
    Eur J Radiol; 2012 Oct; 81(10):2900-6. PubMed ID: 22127374
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Non-contrast-enhanced preoperative assessment of lung perfusion in patients with non-small-cell lung cancer using Fourier decomposition magnetic resonance imaging.
    Sommer G; Bauman G; Koenigkam-Santos M; Draenkow C; Heussel CP; Kauczor HU; Schlemmer HP; Puderbach M
    Eur J Radiol; 2013 Dec; 82(12):e879-87. PubMed ID: 24041434
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Contrast-enhanced 3D MR perfusion of the lung: application of parallel imaging technique in healthy subjects].
    Ley S; Fink C; Puderbach M; Plathow C; Risse F; Kreitner KF; Kauczor HU
    Rofo; 2004 Mar; 176(3):330-4. PubMed ID: 15026945
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Noninvasive assessment of pulmonary emphysema using dynamic contrast-enhanced magnetic resonance imaging.
    Morino S; Toba T; Araki M; Azuma T; Tsutsumi S; Tao H; Nakamura T; Nagayasu T; Tagawa T
    Exp Lung Res; 2006; 32(1-2):55-67. PubMed ID: 16809221
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantitative contrast-enhanced perfusion measurements of the human lung using the prebolus approach.
    Oechsner M; Mühlhäusler M; Ritter CO; Weininger M; Beissert M; Jakob PM; Beer M; Hahn D; Köstler H
    J Magn Reson Imaging; 2009 Jul; 30(1):104-11. PubMed ID: 19557852
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessment of pulmonary perfusion with breath-hold and free-breathing dynamic contrast-enhanced magnetic resonance imaging: quantification and reproducibility.
    Ingrisch M; Maxien D; Schwab F; Reiser MF; Nikolaou K; Dietrich O
    Invest Radiol; 2014 Jun; 49(6):382-9. PubMed ID: 24473368
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantification of pulmonary blood flow (PBF): validation of perfusion MRI and nonlinear contrast agent (CA) dose correction with H(2)15O positron emission tomography (PET).
    Neeb D; Kunz RP; Ley S; Szábo G; Strauss LG; Kauczor HU; Kreitner KF; Schreiber LM
    Magn Reson Med; 2009 Aug; 62(2):476-87. PubMed ID: 19488992
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Breath-hold and free-breathing 2D phase-contrast MRI for quantification of oxygen-induced changes of pulmonary circulation dynamics in healthy volunteers.
    Czerner CP; Winther HB; Zapf A; Wacker F; Vogel-Claussen J
    J Magn Reson Imaging; 2017 Dec; 46(6):1698-1706. PubMed ID: 28383791
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assessment of differential branch pulmonary blood flow: a comparative study of phase contrast magnetic resonance imaging and radionuclide lung perfusion imaging.
    Sridharan S; Derrick G; Deanfield J; Taylor AM
    Heart; 2006 Jul; 92(7):963-8. PubMed ID: 16775104
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Oxygen-enhanced MR imaging of mice lungs.
    Watt KN; Bishop J; Nieman BJ; Henkelman RM; Chen XJ
    Magn Reson Med; 2008 Jun; 59(6):1412-21. PubMed ID: 18421693
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Non-contrast-enhanced perfusion and ventilation assessment of the human lung by means of fourier decomposition in proton MRI.
    Bauman G; Puderbach M; Deimling M; Jellus V; Chefd'hotel C; Dinkel J; Hintze C; Kauczor HU; Schad LR
    Magn Reson Med; 2009 Sep; 62(3):656-64. PubMed ID: 19585597
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Peak velocity measurements in tortuous arteries with phase contrast magnetic resonance imaging: the effect of multidirectional velocity encoding.
    Schubert T; Bieri O; Pansini M; Stippich C; Santini F
    Invest Radiol; 2014 Apr; 49(4):189-94. PubMed ID: 24300842
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Regional pulmonary perfusion using model-free analysis of contrast-enhanced MRI in meconium-aspirated piglets.
    Ryhammer P; Pedersen M; Ringgaard S; Ravn H
    J Magn Reson Imaging; 2007 Aug; 26(2):296-303. PubMed ID: 17654730
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Contrast-enhanced magnetic resonance angiography: first-pass arterial enhancement as a function of gadolinium-chelate concentration, and the saline chaser volume and injection rate.
    Husarik DB; Bashir MR; Weber PW; Nichols EB; Howle LE; Merkle EM; Nelson RC
    Invest Radiol; 2012 Feb; 47(2):121-7. PubMed ID: 21934516
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A vascular stent as an active component for locally enhanced magnetic resonance imaging: initial in vivo imaging results after catheter-guided placement in rabbits.
    Kivelitz D; Wagner S; Schnorr J; Wetzler R; Busch M; Melzer A; Taupitz M; Hamm B
    Invest Radiol; 2003 Mar; 38(3):147-52. PubMed ID: 12595794
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.