BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

296 related articles for article (PubMed ID: 22762843)

  • 1. A tear of the right ventricular outflow tract during pulmonary valvuloplasty treated by transcatheter Sapien valve implantation.
    Kefer J; Gewillig M; Sluysmans T
    Congenit Heart Dis; 2013; 8(4):E111-4. PubMed ID: 22762843
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Use of the Melody™ transcatheter pulmonary valve as a "covered stent" to repair conduit perforation during pulmonary valve implantation.
    Mahgerefteh J; Sutton NJ; Pass RH
    Catheter Cardiovasc Interv; 2013 May; 81(6):980-4. PubMed ID: 22899637
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Off-label use of percutaneous pulmonary valved stents in the right ventricular outflow tract: time to rewrite the label?
    Boshoff DE; Cools BL; Heying R; Troost E; Kefer J; Budts W; Gewillig M
    Catheter Cardiovasc Interv; 2013 May; 81(6):987-95. PubMed ID: 22887796
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transcatheter pulmonary valve implantation using the Edwards SAPIEN transcatheter heart valve.
    Boone RH; Webb JG; Horlick E; Benson L; Cao QL; Nadeem N; Kiess M; Hijazi ZM
    Catheter Cardiovasc Interv; 2010 Feb; 75(2):286-94. PubMed ID: 19924775
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Percutaneous Edwards SAPIEN(™) valve implantation for significant pulmonary regurgitation after previous surgical repair with a right ventricular outflow patch.
    Demkow M; Rużyłło W; Biernacka EK; Kalińczuk Ł; Spiewak M; Kowalski M; Sitkowska E; Kuśmierczyk M; Różanski J; Banaś S; Chmielak Z; Hoffman P
    Catheter Cardiovasc Interv; 2014 Feb; 83(3):474-81. PubMed ID: 23804542
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Infective endocarditis after transcatheter pulmonary valve replacement using the Melody valve: combined results of 3 prospective North American and European studies.
    McElhinney DB; Benson LN; Eicken A; Kreutzer J; Padera RF; Zahn EM
    Circ Cardiovasc Interv; 2013 Jun; 6(3):292-300. PubMed ID: 23735475
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Melody ® transcatheter pulmonary valve implantation: results from a French registry.
    Fraisse A; Aldebert P; Malekzadeh-Milani S; Thambo JB; Piéchaud JF; Aucoururier P; Chatelier G; Bonnet D; Iserin L; Bonello B; Assaidi A; Kammache I; Boudjemline Y
    Arch Cardiovasc Dis; 2014 Nov; 107(11):607-14. PubMed ID: 25453718
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Massive aortic regurgitation following paravalvular balloon valvuloplasty of an Edwards SAPIEN valve treated by emergent CoreValve implantation: never cross a transcatheter aortic valve without a pigtail.
    Noble S; Cikirikcioglu M; Roffi M
    Catheter Cardiovasc Interv; 2013 Oct; 82(4):E609-12. PubMed ID: 23460365
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transcatheter pulmonary valvulation: current indications and available devices.
    Hascoët S; Acar P; Boudjemline Y
    Arch Cardiovasc Dis; 2014 Nov; 107(11):625-34. PubMed ID: 25444020
    [TBL] [Abstract][Full Text] [Related]  

  • 10. One-year follow-up of the Melody transcatheter pulmonary valve multicenter post-approval study.
    Armstrong AK; Balzer DT; Cabalka AK; Gray RG; Javois AJ; Moore JW; Rome JJ; Turner DR; Zellers TM; Kreutzer J
    JACC Cardiovasc Interv; 2014 Nov; 7(11):1254-62. PubMed ID: 25459038
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transcatheter Sapien valve implantation in a native tricuspid valve after failed surgical repair.
    Kefer J; Sluysmans T; Vanoverschelde JL
    Catheter Cardiovasc Interv; 2014 Apr; 83(5):841-5. PubMed ID: 24339249
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Contained rupture of patched right ventricular outflow tracts during balloon sizing for percutaneous pulmonary valve implantation.
    Boe BA; Bocks ML; Armstrong AK
    Catheter Cardiovasc Interv; 2016 Mar; 87(4):768-72. PubMed ID: 26152592
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transcatheter aortic valve-in-valve implantation of a CoreValve in a degenerated stenotic Sapien heart valve prosthesis.
    Hoffmann R; Möllmann H; Lotfi S
    Catheter Cardiovasc Interv; 2013 Dec; 82(7):E922-5. PubMed ID: 22707435
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Predictors and outcomes of right ventricular outflow tract conduit rupture during percutaneous pulmonary valve implantation: a multicentre study.
    Boudjemline Y; Malekzadeh-Milani S; Patel M; Thambo JB; Bonnet D; Iserin L; Fraisse A
    EuroIntervention; 2016 Jan; 11(9):1053-62. PubMed ID: 25244126
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Medtronic Melody® transcatheter pulmonary valve implanted at 24-mm diameter--it works.
    Cheatham SL; Holzer RJ; Chisolm JL; Cheatham JP
    Catheter Cardiovasc Interv; 2013 Nov; 82(5):816-23. PubMed ID: 23359563
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The future of transcatheter pulmonary valvulation.
    Jalal Z; Thambo JB; Boudjemline Y
    Arch Cardiovasc Dis; 2014 Nov; 107(11):635-42. PubMed ID: 25241221
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Percutaneous pulmonary valve implantation using Edwards SAPIEN transcatheter heart valve in different types of conduits: initial results of a single center experience.
    Odemis E; Guzeltas A; Saygi M; Ozyilmaz I; Momenah T; Bakir I
    Congenit Heart Dis; 2013; 8(5):411-7. PubMed ID: 23448542
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Melody transcatheter pulmonary valve implantation. Results from the registry of the Italian Society of Pediatric Cardiology.
    Butera G; Milanesi O; Spadoni I; Piazza L; Donti A; Ricci C; Agnoletti G; Pangrazi A; Chessa M; Carminati M
    Catheter Cardiovasc Interv; 2013 Feb; 81(2):310-6. PubMed ID: 22718682
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Single-center comparative outcomes of the Edwards SAPIEN and Medtronic Melody transcatheter heart valves in the pulmonary position.
    Faza N; Kenny D; Kavinsky C; Amin Z; Heitschmidt M; Hijazi ZM
    Catheter Cardiovasc Interv; 2013 Oct; 82(4):E535-41. PubMed ID: 23008193
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Rare complication of ventricular septal defect in three patients following transcatheter aortic valve replacement.
    Patel Y; Vassileva C; Mishkel G
    Catheter Cardiovasc Interv; 2014 Feb; 83(3):497-501. PubMed ID: 24123754
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.