296 related articles for article (PubMed ID: 22762843)
1. A tear of the right ventricular outflow tract during pulmonary valvuloplasty treated by transcatheter Sapien valve implantation.
Kefer J; Gewillig M; Sluysmans T
Congenit Heart Dis; 2013; 8(4):E111-4. PubMed ID: 22762843
[TBL] [Abstract][Full Text] [Related]
2. Use of the Melody™ transcatheter pulmonary valve as a "covered stent" to repair conduit perforation during pulmonary valve implantation.
Mahgerefteh J; Sutton NJ; Pass RH
Catheter Cardiovasc Interv; 2013 May; 81(6):980-4. PubMed ID: 22899637
[TBL] [Abstract][Full Text] [Related]
3. Off-label use of percutaneous pulmonary valved stents in the right ventricular outflow tract: time to rewrite the label?
Boshoff DE; Cools BL; Heying R; Troost E; Kefer J; Budts W; Gewillig M
Catheter Cardiovasc Interv; 2013 May; 81(6):987-95. PubMed ID: 22887796
[TBL] [Abstract][Full Text] [Related]
4. Transcatheter pulmonary valve implantation using the Edwards SAPIEN transcatheter heart valve.
Boone RH; Webb JG; Horlick E; Benson L; Cao QL; Nadeem N; Kiess M; Hijazi ZM
Catheter Cardiovasc Interv; 2010 Feb; 75(2):286-94. PubMed ID: 19924775
[TBL] [Abstract][Full Text] [Related]
5. Percutaneous Edwards SAPIEN(™) valve implantation for significant pulmonary regurgitation after previous surgical repair with a right ventricular outflow patch.
Demkow M; Rużyłło W; Biernacka EK; Kalińczuk Ł; Spiewak M; Kowalski M; Sitkowska E; Kuśmierczyk M; Różanski J; Banaś S; Chmielak Z; Hoffman P
Catheter Cardiovasc Interv; 2014 Feb; 83(3):474-81. PubMed ID: 23804542
[TBL] [Abstract][Full Text] [Related]
6. Infective endocarditis after transcatheter pulmonary valve replacement using the Melody valve: combined results of 3 prospective North American and European studies.
McElhinney DB; Benson LN; Eicken A; Kreutzer J; Padera RF; Zahn EM
Circ Cardiovasc Interv; 2013 Jun; 6(3):292-300. PubMed ID: 23735475
[TBL] [Abstract][Full Text] [Related]
7. Melody ® transcatheter pulmonary valve implantation: results from a French registry.
Fraisse A; Aldebert P; Malekzadeh-Milani S; Thambo JB; Piéchaud JF; Aucoururier P; Chatelier G; Bonnet D; Iserin L; Bonello B; Assaidi A; Kammache I; Boudjemline Y
Arch Cardiovasc Dis; 2014 Nov; 107(11):607-14. PubMed ID: 25453718
[TBL] [Abstract][Full Text] [Related]
8. Massive aortic regurgitation following paravalvular balloon valvuloplasty of an Edwards SAPIEN valve treated by emergent CoreValve implantation: never cross a transcatheter aortic valve without a pigtail.
Noble S; Cikirikcioglu M; Roffi M
Catheter Cardiovasc Interv; 2013 Oct; 82(4):E609-12. PubMed ID: 23460365
[TBL] [Abstract][Full Text] [Related]
9. Transcatheter pulmonary valvulation: current indications and available devices.
Hascoët S; Acar P; Boudjemline Y
Arch Cardiovasc Dis; 2014 Nov; 107(11):625-34. PubMed ID: 25444020
[TBL] [Abstract][Full Text] [Related]
10. One-year follow-up of the Melody transcatheter pulmonary valve multicenter post-approval study.
Armstrong AK; Balzer DT; Cabalka AK; Gray RG; Javois AJ; Moore JW; Rome JJ; Turner DR; Zellers TM; Kreutzer J
JACC Cardiovasc Interv; 2014 Nov; 7(11):1254-62. PubMed ID: 25459038
[TBL] [Abstract][Full Text] [Related]
11. Transcatheter Sapien valve implantation in a native tricuspid valve after failed surgical repair.
Kefer J; Sluysmans T; Vanoverschelde JL
Catheter Cardiovasc Interv; 2014 Apr; 83(5):841-5. PubMed ID: 24339249
[TBL] [Abstract][Full Text] [Related]
12. Contained rupture of patched right ventricular outflow tracts during balloon sizing for percutaneous pulmonary valve implantation.
Boe BA; Bocks ML; Armstrong AK
Catheter Cardiovasc Interv; 2016 Mar; 87(4):768-72. PubMed ID: 26152592
[TBL] [Abstract][Full Text] [Related]
13. Transcatheter aortic valve-in-valve implantation of a CoreValve in a degenerated stenotic Sapien heart valve prosthesis.
Hoffmann R; Möllmann H; Lotfi S
Catheter Cardiovasc Interv; 2013 Dec; 82(7):E922-5. PubMed ID: 22707435
[TBL] [Abstract][Full Text] [Related]
14. Predictors and outcomes of right ventricular outflow tract conduit rupture during percutaneous pulmonary valve implantation: a multicentre study.
Boudjemline Y; Malekzadeh-Milani S; Patel M; Thambo JB; Bonnet D; Iserin L; Fraisse A
EuroIntervention; 2016 Jan; 11(9):1053-62. PubMed ID: 25244126
[TBL] [Abstract][Full Text] [Related]
15. The Medtronic Melody® transcatheter pulmonary valve implanted at 24-mm diameter--it works.
Cheatham SL; Holzer RJ; Chisolm JL; Cheatham JP
Catheter Cardiovasc Interv; 2013 Nov; 82(5):816-23. PubMed ID: 23359563
[TBL] [Abstract][Full Text] [Related]
16. The future of transcatheter pulmonary valvulation.
Jalal Z; Thambo JB; Boudjemline Y
Arch Cardiovasc Dis; 2014 Nov; 107(11):635-42. PubMed ID: 25241221
[TBL] [Abstract][Full Text] [Related]
17. Percutaneous pulmonary valve implantation using Edwards SAPIEN transcatheter heart valve in different types of conduits: initial results of a single center experience.
Odemis E; Guzeltas A; Saygi M; Ozyilmaz I; Momenah T; Bakir I
Congenit Heart Dis; 2013; 8(5):411-7. PubMed ID: 23448542
[TBL] [Abstract][Full Text] [Related]
18. Melody transcatheter pulmonary valve implantation. Results from the registry of the Italian Society of Pediatric Cardiology.
Butera G; Milanesi O; Spadoni I; Piazza L; Donti A; Ricci C; Agnoletti G; Pangrazi A; Chessa M; Carminati M
Catheter Cardiovasc Interv; 2013 Feb; 81(2):310-6. PubMed ID: 22718682
[TBL] [Abstract][Full Text] [Related]
19. Single-center comparative outcomes of the Edwards SAPIEN and Medtronic Melody transcatheter heart valves in the pulmonary position.
Faza N; Kenny D; Kavinsky C; Amin Z; Heitschmidt M; Hijazi ZM
Catheter Cardiovasc Interv; 2013 Oct; 82(4):E535-41. PubMed ID: 23008193
[TBL] [Abstract][Full Text] [Related]
20. Rare complication of ventricular septal defect in three patients following transcatheter aortic valve replacement.
Patel Y; Vassileva C; Mishkel G
Catheter Cardiovasc Interv; 2014 Feb; 83(3):497-501. PubMed ID: 24123754
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]