BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 22766177)

  • 1. Routine use of duplex real-time PCR assays including a commercial internal control for molecular diagnosis of opportunistic DNA virus infections.
    Burrel S; Fovet C; Brunet C; Ovaguimian L; Hamm N; Conan F; Kalkias L; Agut H; Boutolleau D
    J Virol Methods; 2012 Oct; 185(1):136-41. PubMed ID: 22766177
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A new highly automated extraction system for quantitative real-time PCRs from whole blood samples: routine monitoring of opportunistic infections in immunosuppressed patients.
    Mengelle C; Mansuy JM; Sauné K; Barthe C; Boineau J; Izopet J
    J Clin Virol; 2012 Apr; 53(4):314-9. PubMed ID: 22296792
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Routine use of a highly automated and internally controlled real-time PCR assay for the diagnosis of herpes simplex and varicella-zoster virus infections.
    Stránská R; Schuurman R; de Vos M; van Loon AM
    J Clin Virol; 2004 May; 30(1):39-44. PubMed ID: 15072752
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automated detection of five human herpes virus DNAs by a set of LightCycler PCRs complemented with a single multiple internal control.
    Stöcher M; Hölzl G; Stekel H; Berg J
    J Clin Virol; 2004 Mar; 29(3):171-8. PubMed ID: 14962786
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development and clinical validation of a multiplex real-time PCR assay for herpes simplex and varicella zoster virus.
    Tan TY; Zou H; Ong DC; Ker KJ; Chio MT; Teo RY; Koh MJ
    Diagn Mol Pathol; 2013 Dec; 22(4):245-8. PubMed ID: 24193006
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and inter-laboratory validation study of an improved new real-time PCR assay with internal control for detection and laboratory diagnosis of African swine fever virus.
    Tignon M; Gallardo C; Iscaro C; Hutet E; Van der Stede Y; Kolbasov D; De Mia GM; Le Potier MF; Bishop RP; Arias M; Koenen F
    J Virol Methods; 2011 Dec; 178(1-2):161-70. PubMed ID: 21946285
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development and Validation of a Laboratory-Developed Multiplex Real-Time PCR Assay on the BD Max System for Detection of Herpes Simplex Virus and Varicella-Zoster Virus DNA in Various Clinical Specimens.
    Pillet S; Verhoeven PO; Epercieux A; Bourlet T; Pozzetto B
    J Clin Microbiol; 2015 Jun; 53(6):1921-6. PubMed ID: 25878344
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A multiple SYBR Green I-based real-time PCR system for the simultaneous detection of porcine circovirus type 2, porcine parvovirus, pseudorabies virus and Torque teno sus virus 1 and 2 in pigs.
    Pérez LJ; Perera CL; Frías MT; Núñez JI; Ganges L; de Arce HD
    J Virol Methods; 2012 Jan; 179(1):233-41. PubMed ID: 22119629
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rapid quantitative PCR assays for the simultaneous detection of herpes simplex virus, varicella zoster virus, cytomegalovirus, Epstein-Barr virus, and human herpesvirus 6 DNA in blood and other clinical specimens.
    Engelmann I; Petzold DR; Kosinska A; Hepkema BG; Schulz TF; Heim A
    J Med Virol; 2008 Mar; 80(3):467-77. PubMed ID: 18205230
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A novel multiplex real-time PCR assay for the detection and quantification of HPV16/18 and HSV1/2 in cervical cancer screening.
    Zhao Y; Cao X; Tang J; Zhou L; Gao Y; Wang J; Zheng Y; Yin S; Wang Y
    Mol Cell Probes; 2012 Apr; 26(2):66-72. PubMed ID: 22293505
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of opportunistic DNA viral infections by multiplex PCR among HIV infected individuals receiving care at a tertiary care hospital in South India.
    Sachithanandham J; Ramamurthy M; Kannangai R; Daniel HD; Abraham OC; Rupali P; Pulimood SA; Abraham AM; Sridharan G
    Indian J Med Microbiol; 2009; 27(3):210-6. PubMed ID: 19584500
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of the Roche LightCycler 480 system in a routine laboratory setting for molecular diagnosis of opportunistic viral infections: Evaluation on whole blood specimens and proficiency panels.
    Deback C; Géli J; Aït-Arkoub Z; Angleraud F; Gautheret-Dejean A; Agut H; Boutolleau D
    J Virol Methods; 2009 Aug; 159(2):291-4. PubMed ID: 19490982
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development and validation with clinical samples of internally controlled multiplex real-time PCR for diagnosis of BKV and JCV infection in associated pathologies.
    Bárcena-Panero A; Echevarría JE; Romero-Gómez MP; Royuela E; Castellanos A; González I; Fedele G
    Comp Immunol Microbiol Infect Dis; 2012 Mar; 35(2):173-9. PubMed ID: 22261266
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative evaluation of the QIAGEN QIAsymphony® SP system and bioMérieux NucliSens easyMAG automated extraction platforms in a clinical virology laboratory.
    Lee AV; Atkinson C; Manuel RJ; Clark DA
    J Clin Virol; 2011 Dec; 52(4):339-43. PubMed ID: 22014618
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of multiplex real-time PCR for the rapid detection of five bacterial causes of community acquired pneumonia.
    Al-Marzooq F; Imad MA; How SH; Kuan YC
    Trop Biomed; 2011 Dec; 28(3):545-56. PubMed ID: 22433883
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Evaluation of the LightCycler 480 real-time PCR system for the measurement of CMV, EBV, HHV-6 and BKV viral loads in whole blood].
    Boutolleau D; Deback C; Géli J; Aït-Arkoub Z; Angleraud F; Gautheret-Dejean A; Agut H
    Pathol Biol (Paris); 2010 Apr; 58(2):166-9. PubMed ID: 19892483
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of multiplex PCR for simultaneous detection of six swine DNA and RNA viruses.
    Xu XG; Chen GD; Huang Y; Ding L; Li ZC; Chang CD; Wang CY; Tong DW; Liu HJ
    J Virol Methods; 2012 Jul; 183(1):69-74. PubMed ID: 22575688
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Homogenization with heat treatment: A cost effective alternative to nucleic acid extraction for herpes simplex virus real-time PCR from viral swabs.
    LeBlanc JJ; Heinstein CR; Hatchette TF
    J Virol Methods; 2012 Jan; 179(1):261-4. PubMed ID: 21970946
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Systematic screening of BK virus by real-time PCR prevents BK virus associated nephropathy in renal transplant recipients.
    Hammarin AL; Öqvist B; Wahlgren J; Falk KI
    J Med Virol; 2011 Nov; 83(11):1959-65. PubMed ID: 21915871
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Applicability of a sensitive duplex real-time PCR assay for identifying B/Yamagata and B/Victoria lineages of influenza virus from clinical specimens.
    Zhang N; Fang S; Wang T; Li J; Cheng X; Zhao C; Wang X; Lv X; Wu C; Zhang R; Cheng J; Xue H; Lu Z
    Appl Microbiol Biotechnol; 2012 Jan; 93(2):797-805. PubMed ID: 22113559
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.