220 related articles for article (PubMed ID: 22767167)
1. Repeatability of the Sirius imaging system and agreement with the Pentacam HR.
Nasser CK; Singer R; Barkana Y; Zadok D; Avni I; Goldich Y
J Refract Surg; 2012 Jul; 28(7):493-7. PubMed ID: 22767167
[TBL] [Abstract][Full Text] [Related]
2. Scheimpflug-Placido topographer and optical low-coherence reflectometry biometer: repeatability and agreement.
Chen W; McAlinden C; Pesudovs K; Wang Q; Lu F; Feng Y; Chen J; Huang J
J Cataract Refract Surg; 2012 Sep; 38(9):1626-32. PubMed ID: 22763002
[TBL] [Abstract][Full Text] [Related]
3. Repeatability, reproducibility, and agreement between three different Scheimpflug systems in measuring corneal and anterior segment biometry.
Hernández-Camarena JC; Chirinos-Saldaña P; Navas A; Ramirez-Miranda A; de la Mota A; Jimenez-Corona A; Graue-Hernindez EO
J Refract Surg; 2014 Sep; 30(9):616-21. PubMed ID: 25250418
[TBL] [Abstract][Full Text] [Related]
4. Repeatability and agreement of five imaging systems for measuring anterior segment parameters in healthy eyes.
Kumar M; Shetty R; Jayadev C; Rao HL; Dutta D
Indian J Ophthalmol; 2017 Apr; 65(4):288-294. PubMed ID: 28513492
[TBL] [Abstract][Full Text] [Related]
5. Comparison of central corneal thickness, thinnest corneal thickness, anterior chamber depth, and simulated keratometry using galilei, Pentacam, and Sirius devices.
Anayol MA; Güler E; Yağci R; Şekeroğlu MA; Ylmazoğlu M; Trhş H; Kulak AE; Ylmazbaş P
Cornea; 2014 Jun; 33(6):582-6. PubMed ID: 24763122
[TBL] [Abstract][Full Text] [Related]
6. Comparison of central corneal thickness and anterior chamber depth measured using LenStar LS900, Pentacam, and Visante AS-OCT.
OʼDonnell C; Hartwig A; Radhakrishnan H
Cornea; 2012 Sep; 31(9):983-8. PubMed ID: 22367044
[TBL] [Abstract][Full Text] [Related]
7. Dual versus single Scheimpflug camera for anterior segment analysis: Precision and agreement.
Aramberri J; Araiz L; Garcia A; Illarramendi I; Olmos J; Oyanarte I; Romay A; Vigara I
J Cataract Refract Surg; 2012 Nov; 38(11):1934-49. PubMed ID: 22995705
[TBL] [Abstract][Full Text] [Related]
8. Precision of a new Scheimpflug and Placido-disk analyzer in measuring corneal thickness and agreement with ultrasound pachymetry.
Huang J; Savini G; Hu L; Hoffer KJ; Lu W; Feng Y; Yang F; Hu X; Wang Q
J Cataract Refract Surg; 2013 Feb; 39(2):219-24. PubMed ID: 23218819
[TBL] [Abstract][Full Text] [Related]
9. Repeatability of corneal thickness measured using an Oculus Pentacam.
Miranda MA; Radhakrishnan H; O'Donnell C
Optom Vis Sci; 2009 Mar; 86(3):266-72. PubMed ID: 19214132
[TBL] [Abstract][Full Text] [Related]
10. Repeatability and agreement of three Scheimpflug-based imaging systems for measuring anterior segment parameters in keratoconus.
Shetty R; Arora V; Jayadev C; Nuijts RM; Kumar M; Puttaiah NK; Kummelil MK
Invest Ophthalmol Vis Sci; 2014 Jul; 55(8):5263-8. PubMed ID: 25074774
[TBL] [Abstract][Full Text] [Related]
11. A Comparison between Scheimpflug imaging and optical coherence tomography in measuring corneal thickness.
Huang J; Ding X; Savini G; Pan C; Feng Y; Cheng D; Hua Y; Hu X; Wang Q
Ophthalmology; 2013 Oct; 120(10):1951-8. PubMed ID: 23672973
[TBL] [Abstract][Full Text] [Related]
12. Intrasubject repeatability in keratoconus-eye measurements obtained with a new Scheimpflug photography-based system.
Montalbán R; Alió JL; Javaloy J; Piñero DP
J Cataract Refract Surg; 2013 Feb; 39(2):211-8. PubMed ID: 23218818
[TBL] [Abstract][Full Text] [Related]
13. A comprehensive evaluation of the precision (repeatability and reproducibility) of the Oculus Pentacam HR.
McAlinden C; Khadka J; Pesudovs K
Invest Ophthalmol Vis Sci; 2011 Sep; 52(10):7731-7. PubMed ID: 21810981
[TBL] [Abstract][Full Text] [Related]
14. Single session, intrauser repeatability of anterior chamber biometric and corneal pachy-volumetric parameters using a new Scheimpflug+Placido device.
Prakash G; Srivastava D
J Optom; 2016; 9(2):85-92. PubMed ID: 26338543
[TBL] [Abstract][Full Text] [Related]
15. Repeatability, Reproducibility, and Agreement of Two Scheimpflug-Placido Anterior Corneal Analyzers for Posterior Corneal Surface Measurement.
Bao F; Savini G; Shu B; Zhu S; Gao R; Dang G; Yu A; Wang Q; Huang J
J Refract Surg; 2017 Aug; 33(8):524-530. PubMed ID: 28787517
[TBL] [Abstract][Full Text] [Related]
16. Repeatability and agreement of Scheimpflug-based and swept-source optical biometry measurements.
Sel S; Stange J; Kaiser D; Kiraly L
Cont Lens Anterior Eye; 2017 Oct; 40(5):318-322. PubMed ID: 28342729
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of the repeatability of the Lenstar and comparison with two other non-contact biometric devices in myopes.
Zhao J; Chen Z; Zhou Z; Ding L; Zhou X
Clin Exp Optom; 2013 Jan; 96(1):92-9. PubMed ID: 22943766
[TBL] [Abstract][Full Text] [Related]
18. Repeatability of corneal power and wavefront aberration measurements with a dual-Scheimpflug Placido corneal topographer.
Wang L; Shirayama M; Koch DD
J Cataract Refract Surg; 2010 Mar; 36(3):425-30. PubMed ID: 20202540
[TBL] [Abstract][Full Text] [Related]
19. Repeatability and agreement of 2 Scheimpflug analyzers in measuring the central corneal thickness and anterior chamber angle, volume, and depth.
Bedei A; Appolloni I; Madesani A; Pietrelli A; Franceschi S; Barabesi L
Eur J Ophthalmol; 2012; 22 Suppl 7():S29-32. PubMed ID: 22267453
[TBL] [Abstract][Full Text] [Related]
20. Intrasubject repeatability of corneal morphology measurements obtained with a new Scheimpflug photography-based system.
Montalbán R; Piñero DP; Javaloy J; Alió JL
J Cataract Refract Surg; 2012 Jun; 38(6):971-7. PubMed ID: 22541828
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]