These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

253 related articles for article (PubMed ID: 22770854)

  • 1. Abrasive wear and metallosis associated with cross-linked polyethylene in total hip arthroplasty.
    O'Brien ST; Burnell CD; Hedden DR; Brandt JM
    J Arthroplasty; 2013 Jan; 28(1):197.e17-21. PubMed ID: 22770854
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Severe metallosis leading to femoral head perforation.
    Sharma OP; Lochab J; Berkovich Y; Safir OA; Gross AE
    Orthopedics; 2013 Feb; 36(2):e241-3. PubMed ID: 23383625
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fatal cobalt toxicity after total hip arthroplasty revision for fractured ceramic components.
    Fox KA; Phillips TM; Yanta JH; Abesamis MG
    Clin Toxicol (Phila); 2016 Nov; 54(9):874-877. PubMed ID: 27491800
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fatal cardiomyopathy after revision total hip replacement for fracture of a ceramic liner.
    Zywiel MG; Brandt JM; Overgaard CB; Cheung AC; Turgeon TR; Syed KA
    Bone Joint J; 2013 Jan; 95-B(1):31-7. PubMed ID: 23307670
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Femoral head wear and metallosis caused by damaged titanium porous coating after primary metal-on-polyethylene total hip arthroplasty: a case report.
    Delimar D; Bohaček I; Dimnjaković D; Viderščak D; Schauperl Z
    Croat Med J; 2018 Oct; 59(5):253-257. PubMed ID: 30394017
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Five-year comparison of wear using oxidised zirconium and cobalt-chrome femoral heads in total hip arthroplasty: a multicentre randomised controlled trial.
    Jassim SS; Patel S; Wardle N; Tahmassebi J; Middleton R; Shardlow DL; Stephen A; Hutchinson J; Haddad FS
    Bone Joint J; 2015 Jul; 97-B(7):883-9. PubMed ID: 26130341
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Wear resistant performance of highly cross-linked and annealed ultra-high molecular weight polyethylene against ceramic heads in total hip arthroplasty.
    Sato T; Nakashima Y; Akiyama M; Yamamoto T; Mawatari T; Itokawa T; Ohishi M; Motomura G; Hirata M; Iwamoto Y
    J Orthop Res; 2012 Dec; 30(12):2031-7. PubMed ID: 22644564
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Early failure of the polyethylene liner in the ABG I total hip prosthesis].
    Gallo J; Kamínek P; Zapletalová J; Novotný R; Cechová I; Ditmar R
    Acta Chir Orthop Traumatol Cech; 2003; 70(6):343-9. PubMed ID: 15002349
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vivo femoral head damage and its effect on polyethylene wear.
    Ito H; Maloney CM; Crowninshield RD; Clohisy JC; McDonald DJ; Maloney WJ
    J Arthroplasty; 2010 Feb; 25(2):302-8. PubMed ID: 19201153
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ceramic-on-ceramic failure secondary to head-neck taper mismatch.
    Hohman DW; Affonso J; Anders M
    Am J Orthop (Belle Mead NJ); 2011 Nov; 40(11):571-3. PubMed ID: 22263210
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement. A prospective, randomized study.
    Kim YH
    J Bone Joint Surg Am; 2005 Aug; 87(8):1769-76. PubMed ID: 16085617
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ceramic materials as bearing surfaces for total hip arthroplasty.
    D'Antonio JA; Sutton K
    J Am Acad Orthop Surg; 2009 Feb; 17(2):63-8. PubMed ID: 19202119
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ceramic Femoral Heads Exhibit Lower Wear Rates Compared to Cobalt Chrome: A Meta-Analysis.
    Mertz KC; Yang J; Chung BC; Chen X; Mayfield CK; Heckmann ND
    J Arthroplasty; 2023 Feb; 38(2):397-405. PubMed ID: 36108994
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Metallosis due to abnormal abrasion of the femoral head in bipolar hip prosthesis. Implant retrieval and analysis in six cases.
    Matsuda Y; Yamamuro T
    Med Prog Technol; 1994; 20(3-4):185-9. PubMed ID: 7877563
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Conus hip prosthesis.
    Wagner H; Wagner M
    Acta Chir Orthop Traumatol Cech; 2001; 68(4):213-21. PubMed ID: 11706545
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Metallosis after metal-on-polyethylene total hip arthroplasty.
    Cipriano CA; Issack PS; Beksac B; Della Valle AG; Sculco TP; Salvati EA
    Am J Orthop (Belle Mead NJ); 2008 Feb; 37(2):E18-25. PubMed ID: 18401490
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Does Metal Transfer Differ on Retrieved Ceramic and CoCr Femoral Heads?
    Fredette EK; MacDonald DW; Underwood RJ; Chen AF; Mont MA; Lee GC; Klein GR; Rimnac CM; Kurtz SM
    Biomed Res Int; 2015; 2015():283038. PubMed ID: 26583097
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cup.
    Popescu D; Gallart X; Garcia S; Bori G; Tomas X; Riba J
    Arch Orthop Trauma Surg; 2008 Aug; 128(8):783-5. PubMed ID: 18066561
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Bearing Change to Metal-On-Polyethylene for Ceramic Bearing Fracture in Total Hip Arthroplasty; Does It Work?
    Lee SJ; Kwak HS; Yoo JJ; Kim HJ
    J Arthroplasty; 2016 Jan; 31(1):204-8. PubMed ID: 26404851
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The in vitro genotoxicity of orthopaedic ceramic (Al2O3) and metal (CoCr alloy) particles.
    Tsaousi A; Jones E; Case CP
    Mutat Res; 2010 Mar; 697(1-2):1-9. PubMed ID: 20139029
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.