These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
6. Reference-free PRFS MR-thermometry using near-harmonic 2-D reconstruction of the background phase. Salomir R; Viallon M; Kickhefel A; Roland J; Morel DR; Petrusca L; Auboiroux V; Goget T; Terraz S; Becker CD; Gross P IEEE Trans Med Imaging; 2012 Feb; 31(2):287-301. PubMed ID: 21937345 [TBL] [Abstract][Full Text] [Related]
7. Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging. Viallon M; Terraz S; Roland J; Dumont E; Becker CD; Salomir R Med Phys; 2010 Apr; 37(4):1491-506. PubMed ID: 20443470 [TBL] [Abstract][Full Text] [Related]
8. MRI-guided gas bubble enhanced ultrasound heating in in vivo rabbit thigh. Sokka SD; King R; Hynynen K Phys Med Biol; 2003 Jan; 48(2):223-41. PubMed ID: 12587906 [TBL] [Abstract][Full Text] [Related]
9. Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model. Adams MS; Salgaonkar VA; Plata-Camargo J; Jones PD; Pascal-Tenorio A; Chen HY; Bouley DM; Sommer G; Pauly KB; Diederich CJ Med Phys; 2016 Jul; 43(7):4184. PubMed ID: 27370138 [TBL] [Abstract][Full Text] [Related]
10. A nonparametric temperature controller with nonlinear negative reaction for multi-point rapid MR-guided HIFU ablation. Petrusca L; Auboiroux V; Goget T; Viallon M; Muller A; Gross P; Becker CD; Salomir R IEEE Trans Med Imaging; 2014 Jun; 33(6):1324-37. PubMed ID: 24893259 [TBL] [Abstract][Full Text] [Related]
11. An MR-compliant phased-array HIFU transducer with augmented steering range, dedicated to abdominal thermotherapy. Auboiroux V; Dumont E; Petrusca L; Viallon M; Salomir R Phys Med Biol; 2011 Jun; 56(12):3563-82. PubMed ID: 21606558 [TBL] [Abstract][Full Text] [Related]
12. Automatic temperature control for MR-guided interstitial ultrasound ablation in liver using a percutaneous applicator: ex vivo and in vivo initial studies. Delabrousse E; Salomir R; Birer A; Paquet C; Mithieux F; Chapelon JY; Cotton F; Lafon C Magn Reson Med; 2010 Mar; 63(3):667-79. PubMed ID: 20187177 [TBL] [Abstract][Full Text] [Related]
13. Magnetic resonance imaging for the exploitation of bubble-enhanced heating by high-intensity focused ultrasound: a feasibility study in ex vivo liver. Elbes D; Denost Q; Robert B; Köhler MO; Tanter M; Bruno Q Ultrasound Med Biol; 2014 May; 40(5):956-64. PubMed ID: 24462160 [TBL] [Abstract][Full Text] [Related]
14. Curvilinear transurethral ultrasound applicator for selective prostate thermal therapy. Ross AB; Diederich CJ; Nau WH; Rieke V; Butts RK; Sommer G; Gill H; Bouley DM Med Phys; 2005 Jun; 32(6):1555-65. PubMed ID: 16013714 [TBL] [Abstract][Full Text] [Related]
15. Improved intercostal HIFU ablation using a phased array transducer based on Fermat's spiral and Voronoi tessellation: A numerical evaluation. Ramaekers P; Ries M; Moonen CT; de Greef M Med Phys; 2017 Mar; 44(3):1071-1088. PubMed ID: 28058731 [TBL] [Abstract][Full Text] [Related]
16. The feasibility of MRI-guided whole prostate ablation with a linear aperiodic intracavitary ultrasound phased array. Sokka SD; Hynynen KH Phys Med Biol; 2000 Nov; 45(11):3373-83. PubMed ID: 11098911 [TBL] [Abstract][Full Text] [Related]
17. Model-based feasibility assessment and evaluation of prostate hyperthermia with a commercial MR-guided endorectal HIFU ablation array. Salgaonkar VA; Prakash P; Rieke V; Ozhinsky E; Plata J; Kurhanewicz J; Hsu IC; Diederich CJ Med Phys; 2014 Mar; 41(3):033301. PubMed ID: 24593742 [TBL] [Abstract][Full Text] [Related]
18. A long arm for ultrasound: a combined robotic focused ultrasound setup for magnetic resonance-guided focused ultrasound surgery. Krafft AJ; Jenne JW; Maier F; Stafford RJ; Huber PE; Semmler W; Bock M Med Phys; 2010 May; 37(5):2380-93. PubMed ID: 20527572 [TBL] [Abstract][Full Text] [Related]
19. Real-time volumetric MRI thermometry of focused ultrasound ablation in vivo: a feasibility study in pig liver and kidney. Quesson B; Laurent C; Maclair G; de Senneville BD; Mougenot C; Ries M; Carteret T; Rullier A; Moonen CT NMR Biomed; 2011 Feb; 24(2):145-53. PubMed ID: 21344531 [TBL] [Abstract][Full Text] [Related]