These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Application of computerised correction method for optical distortion of two-dimensional facial image in superimposition between three-dimensional and two-dimensional facial images. Biwasaka H; Tokuta T; Sasaki Y; Sato K; Takagi T; Tanijiri T; Miyasaka S; Takamiya M; Aoki Y Forensic Sci Int; 2010 Apr; 197(1-3):97-104. PubMed ID: 20116945 [TBL] [Abstract][Full Text] [Related]
3. A new method for distortion correction of electronic endoscope images. Haneishi H; Yagihashi Y; Miyake Y IEEE Trans Med Imaging; 1995; 14(3):548-55. PubMed ID: 18215859 [TBL] [Abstract][Full Text] [Related]
4. Correction of spatial distortion in EPI due to inhomogeneous static magnetic fields using the reversed gradient method. Morgan PS; Bowtell RW; McIntyre DJ; Worthington BS J Magn Reson Imaging; 2004 Apr; 19(4):499-507. PubMed ID: 15065175 [TBL] [Abstract][Full Text] [Related]
5. Computational method for correcting complex optical distortion based on FOV division. Li A; Wu Y; Xia X; Huang Y; Feng C; Zheng Z Appl Opt; 2015 Mar; 54(9):2441-9. PubMed ID: 25968533 [TBL] [Abstract][Full Text] [Related]
7. The effects of geometric distortion correction on motion realignment in fMRI. Elliott MA; Gualtieri EE; Hulvershorn J; Ragland JD; Gur R Acad Radiol; 2004 Sep; 11(9):1005-10. PubMed ID: 15350581 [TBL] [Abstract][Full Text] [Related]
8. A complete distortion correction for MR images: I. Gradient warp correction. Doran SJ; Charles-Edwards L; Reinsberg SA; Leach MO Phys Med Biol; 2005 Apr; 50(7):1343-61. PubMed ID: 15798328 [TBL] [Abstract][Full Text] [Related]
9. Distortion correction and image registration of ultralarge field of view near-eye display device. Li H; Li H; Xu L; Liu X Appl Opt; 2020 May; 59(14):4422-4431. PubMed ID: 32400422 [TBL] [Abstract][Full Text] [Related]
10. Design of an off-axis see-through display based on a dynamic phase correction approach. Beuret M; Twardowski P; Fontaine J Opt Express; 2011 Sep; 19(20):19688-701. PubMed ID: 21996911 [TBL] [Abstract][Full Text] [Related]
11. Measurement of microtomy-induced section distortion and its correction for 3-dimensional histological reconstructions. Jones AS; Milthorpe BK; Howlett CR Cytometry; 1994 Feb; 15(2):95-105. PubMed ID: 8168406 [TBL] [Abstract][Full Text] [Related]
12. A new approach for nonlinear distortion correction in endoscopic images based on least squares estimation. Asari KV; Kumar S; Radhakrishnan D IEEE Trans Med Imaging; 1999 Apr; 18(4):345-54. PubMed ID: 10385291 [TBL] [Abstract][Full Text] [Related]
13. Videoendoscopic distortion correction and its application to virtual guidance of endoscopy. Helferty JP; Zhang C; McLennan G; Higgins WE IEEE Trans Med Imaging; 2001 Jul; 20(7):605-17. PubMed ID: 11465467 [TBL] [Abstract][Full Text] [Related]
14. Predictive (un)distortion model and 3-D reconstruction by biplane snakes. Cañero C; Vilariño F; Mauri J; Radeva P IEEE Trans Med Imaging; 2002 Sep; 21(9):1188-201. PubMed ID: 12564886 [TBL] [Abstract][Full Text] [Related]
15. EPI distortion correction from a simultaneously acquired distortion map using TRAIL. Priest AN; De Vita E; Thomas DL; Ordidge RJ J Magn Reson Imaging; 2006 Apr; 23(4):597-603. PubMed ID: 16514595 [TBL] [Abstract][Full Text] [Related]
16. Correction for susceptibility-induced distortion in echo-planar imaging using field maps and model-based point spread function. Hsu YC; Hsu CH; Tseng WY IEEE Trans Med Imaging; 2009 Nov; 28(11):1850-7. PubMed ID: 19605319 [TBL] [Abstract][Full Text] [Related]
17. Design and fabrication of a holographic head-up display with asymmetric field of view. Peng H; Cheng D; Han J; Xu C; Song W; Ha L; Yang J; Hu Q; Wang Y Appl Opt; 2014 Oct; 53(29):H177-85. PubMed ID: 25322417 [TBL] [Abstract][Full Text] [Related]
18. Camera lens radial distortion correction using two-view projective invariants. Du X; Li H; Zhu Y Opt Lett; 2011 Dec; 36(24):4734-6. PubMed ID: 22179866 [TBL] [Abstract][Full Text] [Related]
19. High-definition mapping of neural activity using voltage-sensitive dyes. Cinelli AR Methods; 2000 Aug; 21(4):349-72. PubMed ID: 10964579 [TBL] [Abstract][Full Text] [Related]
20. Estimation of mutual information objective function based on Fourier shift theorem: an application to eddy current distortion correction in diffusion tensor imaging. Techavipoo U; Lackey J; Shi J; Guan X; Lai S Magn Reson Imaging; 2009 Nov; 27(9):1281-92. PubMed ID: 19608366 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]