479 related articles for article (PubMed ID: 22773015)
21. The first 100 patients treated with a new anatomical pre-contoured locking plate for clavicular midshaft fractures.
Reisch T; Camenzind RS; Fuhrer R; Riede U; Helmy N
BMC Musculoskelet Disord; 2019 Jan; 20(1):4. PubMed ID: 30611253
[TBL] [Abstract][Full Text] [Related]
22. Use of a real-size 3D-printed model as a preoperative and intraoperative tool for minimally invasive plating of comminuted midshaft clavicle fractures.
Kim HN; Liu XN; Noh KC
J Orthop Surg Res; 2015 Jun; 10():91. PubMed ID: 26054648
[TBL] [Abstract][Full Text] [Related]
23. Minimal Invasive Percutaneous Plate Osteosynthesis (MIPPO) vs. Open Plating in Superior Plating of Midshaft Clavicle Fractures.
Zehir S; Sahin E; Songür M; Altunkiliç T; ÖZdemir G
Acta Orthop Belg; 2018 Dec; 84(4):491-496. PubMed ID: 30879455
[No Abstract] [Full Text] [Related]
24. Treatment of middle-third clavicle fractures using anterior plating with a dynamic compression plate (DCP).
Subramanian P; Joshi M; Shilston S; Wallace D; Pearce OJ
Tech Hand Up Extrem Surg; 2013 Mar; 17(1):35-6. PubMed ID: 23423233
[TBL] [Abstract][Full Text] [Related]
25. A new approach for plate fixation of midshaft clavicular fractures.
Coupe BD; Wimhurst JA; Indar R; Calder DA; Patel AD
Injury; 2005 Oct; 36(10):1166-71. PubMed ID: 16076467
[TBL] [Abstract][Full Text] [Related]
26. Comparison of post-operative numbness and patient satisfaction using minimally invasive plate osteosynthesis or open plating for acute displaced clavicular shaft fractures.
You JM; Wu YS; Wang Y
Int J Surg; 2018 Aug; 56():21-25. PubMed ID: 29890301
[TBL] [Abstract][Full Text] [Related]
27. Comparison of implant failure rates of different plates for midshaft clavicular fractures based on fracture classifications.
Chiu YC; Huang KC; Shih CM; Lee KT; Chen KH; Hsu CE
J Orthop Surg Res; 2019 Jul; 14(1):220. PubMed ID: 31311567
[TBL] [Abstract][Full Text] [Related]
28. [Minimally invasive osteosynthesis with blocked anatomical plate in displaced fractures of the middle third of the clavicle].
Cárdenas G
Acta Ortop Mex; 2021; 35(5):479-485. PubMed ID: 35451261
[TBL] [Abstract][Full Text] [Related]
29. Displaced medial end clavicular fractures treated with an inverted distal clavicle plate contoured through 90 degrees.
Titchener A; See A; Van Rensburg L; Tytherleigh-Strong G
J Shoulder Elbow Surg; 2019 Apr; 28(4):e97-e103. PubMed ID: 30454930
[TBL] [Abstract][Full Text] [Related]
30. Anatomic reconstruction of unstable lateral clavicular fractures.
Largo RD; Rudin MA; Hotz TK; Valderrabano V; Käch KK
J Trauma; 2011 Nov; 71(5):1348-51. PubMed ID: 21610538
[TBL] [Abstract][Full Text] [Related]
31. Minimally invasive plate osteosynthesis (MIPO) in AO/OTA type B displaced clavicle fractures.
Kundangar RS; Mohanty SP; Bhat NS
Musculoskelet Surg; 2019 Aug; 103(2):191-197. PubMed ID: 30519988
[TBL] [Abstract][Full Text] [Related]
32. A biomechanical comparison of superior and anterior positioning of precontoured plates for midshaft clavicle fractures.
Toogood P; Coughlin D; Rodriguez D; Lotz J; Feeley B
Am J Orthop (Belle Mead NJ); 2014 Oct; 43(10):E226-31. PubMed ID: 25303449
[TBL] [Abstract][Full Text] [Related]
33. Dual mini-fragment plating for midshaft clavicle fractures: a clinical and biomechanical investigation.
Prasarn ML; Meyers KN; Wilkin G; Wellman DS; Chan DB; Ahn J; Lorich DG; Helfet DL
Arch Orthop Trauma Surg; 2015 Dec; 135(12):1655-62. PubMed ID: 26377733
[TBL] [Abstract][Full Text] [Related]
34. Precontoured dynamic compression plate using patient-specific 3D-printed models in minimally invasive surgical technique for midshaft clavicle fractures.
Jirangkul P; Lorsuwannarat N; Wanichjaroen N
Arch Orthop Trauma Surg; 2024 Jan; 144(1):103-111. PubMed ID: 37658855
[TBL] [Abstract][Full Text] [Related]
35. Dual Mini-Fragment Plate Fixation of Midshaft Clavicle Fractures Reduces Risk of Reoperation Compared With Single-Plate Fixation Techniques.
Reddy RP; Charles S; Como M; Chen SR; Mittwede PN; Rai A; Moloney GB; Sabzevari S; Lin A
Am J Sports Med; 2023 Nov; 51(13):3393-3400. PubMed ID: 37849249
[TBL] [Abstract][Full Text] [Related]
36. Prognostic Factors for Reoperation After Plate Fixation of the Midshaft Clavicle.
Schemitsch LA; Schemitsch EH; Kuzyk P; McKee MD
J Orthop Trauma; 2015 Dec; 29(12):533-7. PubMed ID: 26131565
[TBL] [Abstract][Full Text] [Related]
37. A three-dimensional reconstruction plate for displaced midshaft fractures of the clavicle.
Shen JW; Tong PJ; Qu HB
J Bone Joint Surg Br; 2008 Nov; 90(11):1495-8. PubMed ID: 18978272
[TBL] [Abstract][Full Text] [Related]
38. Surgical treatment of displaced midshaft clavicular fractures with precontoured plates.
Ranalletta M; Rossi LA; Bongiovanni SL; Tanoira I; Piuzzi NS; Maignon G
J Shoulder Elbow Surg; 2015 Jul; 24(7):1036-40. PubMed ID: 25659865
[TBL] [Abstract][Full Text] [Related]
39. Retrospective comparison of titanium elastic nail (TEN) and reconstruction plate repair of displaced midshaft clavicular fractures.
Chen YF; Wei HF; Zhang C; Zeng BF; Zhang CQ; Xue JF; Xie XT; Lu Y
J Shoulder Elbow Surg; 2012 Apr; 21(4):495-501. PubMed ID: 21641826
[TBL] [Abstract][Full Text] [Related]
40. Biomechanical aspects of locking reconstruction plate positioning in osteosynthesis of transverse clavicle fracture.
Kontautas E; Pijadin A; Vilkauskas A; Domeika A
Medicina (Kaunas); 2012; 48(2):80-3. PubMed ID: 22491383
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]