These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 22773389)

  • 1. Microsuction or "micropusher"-facilitating venous microvascular venous anastomosis.
    Shah AK; Patel NG; Haywood RM
    J Reconstr Microsurg; 2012 Nov; 28(9):631-2. PubMed ID: 22773389
    [No Abstract]   [Full Text] [Related]  

  • 2. Histoacryl® to secure the microvascular venous anastomosis using the coupling device.
    Shah AK; Clibbon JJ
    Microsurgery; 2011 Nov; 31(8):666-7. PubMed ID: 22025382
    [No Abstract]   [Full Text] [Related]  

  • 3. Coupling the venous anastomosis: safe and simple.
    de Bruijn HP; Marck KW
    Microsurgery; 1996; 17(7):414-6. PubMed ID: 9379891
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A surgical tool for facilitating microvascular anastomoses in the rat.
    Iwata T; Matsuura A; Kamei Y; Toriyama K
    J Reconstr Microsurg; 1995 May; 11(3):199-200. PubMed ID: 7650646
    [No Abstract]   [Full Text] [Related]  

  • 5. A newly designed ruler of a 0.1-mm scale on the tip of microsurgical instrument in supermicrosurgery.
    Matsumura N
    Microsurgery; 2011 Nov; 31(8):671-2. PubMed ID: 22025406
    [No Abstract]   [Full Text] [Related]  

  • 6. 1000 consecutive venous anastomoses using the microvascular anastomotic coupler in breast reconstruction.
    Schubert HM; Schoeller T; Wechselberger G
    Plast Reconstr Surg; 2010 Nov; 126(5):1789. PubMed ID: 21042147
    [No Abstract]   [Full Text] [Related]  

  • 7. A simple technique for introducing small diameter vessels into a coupler device.
    Murphy MP; Mc Inerney NM; Browne KM; Henry Caulfield R; Hanson RP
    Microsurgery; 2017 Sep; 37(6):728. PubMed ID: 28032653
    [No Abstract]   [Full Text] [Related]  

  • 8. Blood flow assessment with magnetic resonance imaging after 1.9 microm diode laser-assisted microvascular anastomosis.
    Leclère FM; Schoofs M; Auger F; Buys B; Mordon SR
    Lasers Surg Med; 2010 Apr; 42(4):299-305. PubMed ID: 20432278
    [TBL] [Abstract][Full Text] [Related]  

  • 9. End-to-side venous anastomosis with an anastomotic coupling device for microvascular free-tissue transfer in head and neck reconstruction.
    Chernichenko N; Ross DA; Shin J; Sasaki CT; Ariyan S
    Laryngoscope; 2008 Dec; 118(12):2146-50. PubMed ID: 19029861
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design, fabrication, and testing of a novel end-to-end vascular coupling system.
    Li H; Gale BK; Sant H; Shea J; Agarwal J
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():6593-6. PubMed ID: 25571507
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Venous coupler size in autologous breast reconstruction--does it matter?
    Broer PN; Weichman KE; Tanna N; Wilson S; Ng R; Ahn C; Choi M; Karp NS; Levine JP; Allen RJ
    Microsurgery; 2013 Oct; 33(7):514-8. PubMed ID: 24038542
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simple wire retractor for supermicrosurgical lymphaticovenular anastomosis.
    Kato M; Yamamoto T
    Microsurgery; 2015 May; 35(4):335-6. PubMed ID: 25154473
    [No Abstract]   [Full Text] [Related]  

  • 13. Robotics in plastic and reconstructive surgery: use of a telemanipulator slave robot to perform microvascular anastomoses.
    Katz RD; Taylor JA; Rosson GD; Brown PR; Singh NK
    J Reconstr Microsurg; 2006 Jan; 22(1):53-7. PubMed ID: 16425123
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Christmas tree background for supermicrosurgical anastomosis with the presence of a vertical interval.
    Tashiro K; Mihara M; Todokoro T; Narushima M; Yamamoto T; Iida T; Araki J; Iwamoto T; Koshima I
    J Reconstr Microsurg; 2013 Mar; 29(3):205-8. PubMed ID: 23283816
    [No Abstract]   [Full Text] [Related]  

  • 15. Clinical experience of a microvascular venous coupler device in free tissue transfers.
    Chang KP; Lin SD; Lai CS
    Kaohsiung J Med Sci; 2007 Nov; 23(11):566-72. PubMed ID: 18055305
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Early experience with the new 'megacoupler' ring-pins for microvascular anastomoses.
    Hallock GG; Rice DC
    J Plast Reconstr Aesthet Surg; 2008 Aug; 61(8):974-6. PubMed ID: 18499548
    [No Abstract]   [Full Text] [Related]  

  • 17. The double transverse microvascular clamp: a new instrument for microsurgical anastomoses.
    El-Shazly M
    J Reconstr Microsurg; 2012 Nov; 28(9):577-80. PubMed ID: 22711201
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Microsurgical venous automatic suture using double ring eversion system].
    Bodin F; Ganeval A; Lutz JC; Zink S; Wilk A; Bruant-Rodier C
    Ann Chir Plast Esthet; 2012 Aug; 57(4):323-7. PubMed ID: 22742995
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Managing venous discrepancy: simple method.
    Suri MP; Ahmad QG; Yadav PS
    J Reconstr Microsurg; 2009 Nov; 25(8):497-9. PubMed ID: 19697282
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A new method for microvascular anastomosis: report of experimental and clinical research.
    Kirsch WM; Zhu YH; Hardesty RA; Chapolini R
    Am Surg; 1992 Dec; 58(12):722-7. PubMed ID: 1456593
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.