These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
131 related articles for article (PubMed ID: 2277539)
1. Pattern recognition in biomagnetic signals by spatio-temporal correlation and application to the localisation of propagating neuronal activity. Abraham-Fuchs K; Härer W; Schneider S; Stefan H Med Biol Eng Comput; 1990 Sep; 28(5):398-406. PubMed ID: 2277539 [TBL] [Abstract][Full Text] [Related]
2. Localisation of epileptic foci with multichannel magnetoencephalography, MEG. Knutsson E; Gransberg L Acta Neurochir Suppl; 1995; 64():74-8. PubMed ID: 8748588 [TBL] [Abstract][Full Text] [Related]
3. MEG-EEG Information Fusion and Electromagnetic Source Imaging: From Theory to Clinical Application in Epilepsy. Chowdhury RA; Zerouali Y; Hedrich T; Heers M; Kobayashi E; Lina JM; Grova C Brain Topogr; 2015 Nov; 28(6):785-812. PubMed ID: 26016950 [TBL] [Abstract][Full Text] [Related]
4. The neocortico to mesio-basal limbic propagation of focal epileptic activity during the spike-wave complex. Stefan H; Schneider S; Abraham-Fuchs K; Pawlik G; Feistel H; Bauer J; Neubauer U; Huk WJ; Holthoff V Electroencephalogr Clin Neurophysiol; 1991 Jul; 79(1):1-10. PubMed ID: 1713545 [TBL] [Abstract][Full Text] [Related]
6. [Site and propagation of focal epileptic activity: multichannel MEG/EEG analysis]. Stefan H; Abraham-Fuchs K; Schüler P; Schneider S; Neubauer PU; Huk HJ; Neundörfer B Nervenarzt; 1991 Dec; 62(12):730-9. PubMed ID: 1795752 [TBL] [Abstract][Full Text] [Related]
7. Complex patterns of spatially extended generators of epileptic activity: Comparison of source localization methods cMEM and 4-ExSo-MUSIC on high resolution EEG and MEG data. Chowdhury RA; Merlet I; Birot G; Kobayashi E; Nica A; Biraben A; Wendling F; Lina JM; Albera L; Grova C Neuroimage; 2016 Dec; 143():175-195. PubMed ID: 27561712 [TBL] [Abstract][Full Text] [Related]
8. Combined EEG/MEG can outperform single modality EEG or MEG source reconstruction in presurgical epilepsy diagnosis. Aydin Ü; Vorwerk J; Dümpelmann M; Küpper P; Kugel H; Heers M; Wellmer J; Kellinghaus C; Haueisen J; Rampp S; Stefan H; Wolters CH PLoS One; 2015; 10(3):e0118753. PubMed ID: 25761059 [TBL] [Abstract][Full Text] [Related]
9. Localisation of epileptic foci with electric, magnetic and combined electromagnetic models. Diekmann V; Becker W; Jürgens R; Grözinger B; Kleiser B; Richter HP; Wollinsky KH Electroencephalogr Clin Neurophysiol; 1998 Apr; 106(4):297-313. PubMed ID: 9741758 [TBL] [Abstract][Full Text] [Related]
10. Magnetoencephalography (MEG) predicts focal epileptogenicity in cavernomas. Stefan H; Scheler G; Hummel C; Walter J; Romstöck J; Buchfelder M; Blümcke I J Neurol Neurosurg Psychiatry; 2004 Sep; 75(9):1309-13. PubMed ID: 15314122 [TBL] [Abstract][Full Text] [Related]
11. Hidden Markov modelling of spike propagation from interictal MEG data. Ossadtchi A; Mosher JC; Sutherling WW; Greenblatt RE; Leahy RM Phys Med Biol; 2005 Jul; 50(14):3447-69. PubMed ID: 16177520 [TBL] [Abstract][Full Text] [Related]
12. Signal space separation algorithm and its application on suppressing artifacts caused by vagus nerve stimulation for magnetoencephalography recordings. Song T; Cui L; Gaa K; Feffer L; Taulu S; Lee RR; Huang M J Clin Neurophysiol; 2009 Dec; 26(6):392-400. PubMed ID: 19952563 [TBL] [Abstract][Full Text] [Related]
13. Reliability of MEG source imaging of anterior temporal spikes: analysis of an intracranially characterized spike focus. Wennberg R; Cheyne D Clin Neurophysiol; 2014 May; 125(5):903-18. PubMed ID: 24210513 [TBL] [Abstract][Full Text] [Related]
14. Spatiotemporal Accuracy of Gradient Magnetic-Field Topography (GMFT) Confirmed by Simultaneous Magnetoencephalography and Intracranial Electroencephalography Recordings in Patients with Intractable Epilepsy. Shirozu H; Hashizume A; Masuda H; Fukuda M; Ito Y; Nakayama Y; Higashijima T; Kameyama S Front Neural Circuits; 2016; 10():65. PubMed ID: 27594827 [TBL] [Abstract][Full Text] [Related]
16. A simple method for 3-dimensional localization of epileptic activity recorded by simultaneous EEG and MEG. Salustri C; Chapman RM Electroencephalogr Clin Neurophysiol; 1989 Dec; 73(6):473-8. PubMed ID: 2480882 [TBL] [Abstract][Full Text] [Related]
17. An analysis of epileptic negative myoclonus by magnetoencephalography. Yoshimura M; Zhang S; Ueda Y; Matsuda K; Imai K; Takahashi Y; Inoue Y Epilepsy Res; 2015 Feb; 110():139-45. PubMed ID: 25616466 [TBL] [Abstract][Full Text] [Related]
18. The role of MEG in pre-surgical evaluation of epilepsy: current use and future directions. Ahmed R; Rutka JT Expert Rev Neurother; 2016 Jul; 16(7):795-801. PubMed ID: 27101469 [TBL] [Abstract][Full Text] [Related]
19. Epileptic MEG Spike Detection Using Statistical Features and Genetic Programming with KNN. Alotaiby TN; Alrshoud SR; Alshebeili SA; Alhumaid MH; Alsabhan WM J Healthc Eng; 2017; 2017():3035606. PubMed ID: 29118962 [TBL] [Abstract][Full Text] [Related]
20. Magnetoencephalography and magnetic source imaging in epilepsy. Funke M; Constantino T; Van Orman C; Rodin E Clin EEG Neurosci; 2009 Oct; 40(4):271-80. PubMed ID: 19780348 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]