BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 22778649)

  • 21. The use of radiographic film for linear accelerator stereotactic radiosurgical dosimetry.
    Robar JL; Clark BG
    Med Phys; 1999 Oct; 26(10):2144-50. PubMed ID: 10535631
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Miniature scintillating detector for small field radiation therapy.
    Létourneau D; Pouliot J; Roy R
    Med Phys; 1999 Dec; 26(12):2555-61. PubMed ID: 10619239
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters.
    Bache ST; Juang T; Belley MD; Koontz BF; Adamovics J; Yoshizumi TT; Kirsch DG; Oldham M
    Med Phys; 2015 Feb; 42(2):846-55. PubMed ID: 25652497
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A feasibility study of Dynamic Phantom scanner for quality assurance of photon beam profiles at various gantry angles.
    Zhang Y; Hsi WC; Chu JC; Bernard DB; Abrams RA
    J Appl Clin Med Phys; 2005; 6(2):50-61. PubMed ID: 15940212
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Development of a fibre-optic dosemeter to measure the skin dose and percentage depth dose in the build-up region of therapeutic photon beams.
    Kim KA; Yoo WJ; Jang KW; Moon J; Han KT; Jeon D; Park JY; Cha EJ; Lee B
    Radiat Prot Dosimetry; 2013 Mar; 153(3):294-9. PubMed ID: 22764176
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Monte Carlo validation of the TrueBeam 10XFFF phase-space files for applications in lung SABR.
    Teke T; Duzenli C; Bergman A; Viel F; Atwal P; Gete E
    Med Phys; 2015 Dec; 42(12):6863-74. PubMed ID: 26632043
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Monte Carlo simulation of conical collimators for stereotactic radiosurgery with a 6 MV flattening-filter-free photon beam.
    Hermida-López M; Sánchez-Artuñedo D; Rodríguez M; Brualla L
    Med Phys; 2021 Jun; 48(6):3160-3171. PubMed ID: 33715167
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Determination of zero-field size percent depth doses and tissue maximum ratios for stereotactic radiosurgery and IMRT dosimetry: comparison between experimental measurements and Monte Carlo simulation.
    Cheng CW; Cho SH; Taylor M; Das IJ
    Med Phys; 2007 Aug; 34(8):3149-57. PubMed ID: 17879776
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Conversion of measured percentage depth dose to tissue maximum ratio values in stereotactic radiotherapy.
    van Battum LJ; Essers M; Storchi PR
    Phys Med Biol; 2002 Sep; 47(18):3289-300. PubMed ID: 12375821
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Synchrotron stereotactic radiotherapy: dosimetry by Fricke gel and Monte Carlo simulations.
    Boudou C; Biston MC; Corde S; Adam JF; Ferrero C; Estève F; Elleaume H
    Phys Med Biol; 2004 Nov; 49(22):5135-44. PubMed ID: 15609563
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Application of polymer gel dosimetry in gamma knife radiosurgery.
    Novotný J; Novotný J; Spevácek V; Dvorák P; Cechak T; Liscák R; Brozek G; Tintĕra J; Vymazal J
    J Neurosurg; 2002 Dec; 97(5 Suppl):556-62. PubMed ID: 12507096
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Monte Carlo verification of gel dosimetry measurements for stereotactic radiotherapy.
    Kairn T; Taylor ML; Crowe SB; Dunn L; Franich RD; Kenny J; Knight RT; Trapp JV
    Phys Med Biol; 2012 Jun; 57(11):3359-69. PubMed ID: 22572565
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Surface dosimetry for oblique tangential photon beams: a Monte Carlo simulation study.
    Chow JC; Grigorov GN
    Med Phys; 2008 Jan; 35(1):70-6. PubMed ID: 18293563
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Photoneutron depth dose equivalent distributions in high-energy X-ray medical accelerators by a novel position-sensitive dosimeter.
    Hakimi A; Sohrabi M
    Phys Med; 2017 Apr; 36():73-80. PubMed ID: 28410689
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Tomographic-based 3D scintillation dosimetry using a three-view plenoptic imaging system.
    Rilling M; Allain G; Thibault S; Archambault L
    Med Phys; 2020 Aug; 47(8):3636-3646. PubMed ID: 32445200
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.
    Togno M; Wilkens JJ; Menichelli D; Oechsner M; Perez-Andujar A; Morin O
    Med Phys; 2016 May; 43(5):2283. PubMed ID: 27147340
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Correction factor measurements for multiple detectors used in small field dosimetry on the Varian Edge radiosurgery system.
    Tanny S; Sperling N; Parsai EI
    Med Phys; 2015 Sep; 42(9):5370-6. PubMed ID: 26328986
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Investigation of photon beam models in heterogeneous media of modern radiotherapy.
    Ding W; Johnston PN; Wong TP; Bubb IF
    Australas Phys Eng Sci Med; 2004 Jun; 27(2):39-48. PubMed ID: 15462585
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A round-robin gamma stereotactic radiosurgery dosimetry interinstitution comparison of calibration protocols.
    Drzymala RE; Alvarez PE; Bednarz G; Bourland JD; DeWerd LA; Ma L; Meltsner SG; Neyman G; Novotny J; Petti PL; Rivard MJ; Shiu AS; Goetsch SJ
    Med Phys; 2015 Nov; 42(11):6745-56. PubMed ID: 26520764
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Simultaneous measurements of pure scintillation and Cerenkov signals in an integrated fiber-optic dosimeter for electron beam therapy dosimetry.
    Yoo WJ; Shin SH; Jeon D; Hong S; Kim SG; Sim HI; Jang KW; Cho S; Lee B
    Opt Express; 2013 Nov; 21(23):27770-9. PubMed ID: 24514292
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.