2. Noninvasive measurement of blood pressure variability: accuracy of the Finometer monitor and comparison with the Finapres device. Maestri R; Pinna GD; Robbi E; Capomolla S; La Rovere MT Physiol Meas; 2005 Dec; 26(6):1125-36. PubMed ID: 16311459 [TBL] [Abstract][Full Text] [Related]
3. A new noninvasive device for continuous arterial blood pressure monitoring in the superficial temporal artery. Chin KY; Panerai RB Physiol Meas; 2013 Apr; 34(4):407-21. PubMed ID: 23524512 [TBL] [Abstract][Full Text] [Related]
4. Transient drifts between Finapres and continuous intra-aortic measurements of blood pressure. Panerai RB; Sammons EL; Smith SM; Rathbone WE; Bentley S; Potter JF; Samani NJ Blood Press Monit; 2007 Dec; 12(6):369-76. PubMed ID: 18004105 [TBL] [Abstract][Full Text] [Related]
5. Noninvasive assessment of blood pressure variability in preterm infants. Andriessen P; Schoffelen RL; Berendsen RC; de Beer NA; Oei SG; Wijn PF; Blanco CE Pediatr Res; 2004 Feb; 55(2):220-3. PubMed ID: 14630986 [TBL] [Abstract][Full Text] [Related]
6. Effect of the shapes of the oscillometric pulse amplitude envelopes and their characteristic ratios on the differences between auscultatory and oscillometric blood pressure measurements. Amoore JN; Vacher E; Murray IC; Mieke S; King ST; Smith FE; Murray A Blood Press Monit; 2007 Oct; 12(5):297-305. PubMed ID: 17890968 [TBL] [Abstract][Full Text] [Related]
7. Validation of brachial artery pressure reconstruction from finger arterial pressure. Guelen I; Westerhof BE; van der Sar GL; van Montfrans GA; Kiemeneij F; Wesseling KH; Bos WJ J Hypertens; 2008 Jul; 26(7):1321-7. PubMed ID: 18551006 [TBL] [Abstract][Full Text] [Related]
8. Pulse wave analysis on fingertip arterial pressure: effects of age, gender and stressors on reflected waves and their relation to brachial and femoral artery blood flow. Ahlund C; Pettersson K; Lind L Clin Physiol Funct Imaging; 2008 Mar; 28(2):86-95. PubMed ID: 18034848 [TBL] [Abstract][Full Text] [Related]
9. Automatic blood pressure measurement: the oscillometric waveform shape is a potential contributor to differences between oscillometric and auscultatory pressure measurements. Amoore JN; Lemesre Y; Murray IC; Mieke S; King ST; Smith FE; Murray A J Hypertens; 2008 Jan; 26(1):35-43. PubMed ID: 18090538 [TBL] [Abstract][Full Text] [Related]
10. An accuracy evaluation of the T-Line Tensymeter (continuous noninvasive blood pressure management device) versus conventional invasive radial artery monitoring in surgical patients. Janelle GM; Gravenstein N Anesth Analg; 2006 Feb; 102(2):484-90. PubMed ID: 16428547 [TBL] [Abstract][Full Text] [Related]
11. The influence of calculation method on estimates of cerebral critical closing pressure. Panerai RB; Salinet AS; Brodie FG; Robinson TG Physiol Meas; 2011 Apr; 32(4):467-82. PubMed ID: 21403183 [TBL] [Abstract][Full Text] [Related]
12. Continuous non-invasive blood pressure monitoring: reliability of Finapres device during the Valsalva manoeuvre. Imholz BP; van Montfrans GA; Settels JJ; van der Hoeven GM; Karemaker JM; Wieling W Cardiovasc Res; 1988 Jun; 22(6):390-7. PubMed ID: 3224351 [TBL] [Abstract][Full Text] [Related]
13. Accuracy of radial artery blood pressure determination with the Vasotrac. Belani KG; Buckley JJ; Poliac MO Can J Anaesth; 1999 May; 46(5 Pt 1):488-96. PubMed ID: 10349931 [TBL] [Abstract][Full Text] [Related]
14. Comparison of intrabrachial and finger blood pressure in healthy elderly volunteers. Rongen GA; Bos WJ; Lenders JW; van Montfrans GA; van Lier HJ; van Goudoever J; Wesseling KH; Thien T Am J Hypertens; 1995 Mar; 8(3):237-48. PubMed ID: 7794572 [TBL] [Abstract][Full Text] [Related]
15. Feasibility of noninvasive continuous finger arterial blood pressure measurements in very young children, aged 0-4 years. Andriessen P; Schraa O; van Den Bosch-Ruis W; Jan Ten Harkel D; Settels JJ; Oetomo SB; Blanco CE Pediatr Res; 2008 Jun; 63(6):691-6. PubMed ID: 18520333 [TBL] [Abstract][Full Text] [Related]
16. [Comparison between brachial blood pressures obtained by aneroid sphygmomanometer and central aortic pressures: factors affecting the measurements]. Kayrak M; Ulgen MS; Yazici M; Demir K; Doğan Y; Koç F; Zengin K; Ari H Turk Kardiyol Dern Ars; 2008 Jun; 36(4):239-46. PubMed ID: 18765967 [TBL] [Abstract][Full Text] [Related]
17. Influence of non-invasive measurements of arterial blood pressure in frequency and time-domain estimates of cardiac baroreflex sensitivity. Smith SM; Samani NJ; Sammons EL; Rathbone WE; Potter JF; Bentley S; Panerai RB J Hypertens; 2008 Jan; 26(1):76-82. PubMed ID: 18090543 [TBL] [Abstract][Full Text] [Related]
18. Continuous estimates of dynamic cerebral autoregulation: influence of non-invasive arterial blood pressure measurements. Panerai RB; Sammons EL; Smith SM; Rathbone WE; Bentley S; Potter JF; Samani NJ Physiol Meas; 2008 Apr; 29(4):497-513. PubMed ID: 18401070 [TBL] [Abstract][Full Text] [Related]
19. Augmented blood pressure measurement through the noninvasive estimation of physiological arterial pressure variability. Soueidan K; Chen S; Dajani HR; Bolic M; Groza V Physiol Meas; 2012 Jun; 33(6):881-99. PubMed ID: 22551623 [TBL] [Abstract][Full Text] [Related]
20. Validity and reliability of central blood pressure estimated by upper arm oscillometric cuff pressure. Climie RE; Schultz MG; Nikolic SB; Ahuja KD; Fell JW; Sharman JE Am J Hypertens; 2012 Apr; 25(4):414-20. PubMed ID: 22223041 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]