These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 2279039)

  • 1. Model surgery for orthognathic planning.
    Anwar M; Harris M
    Br J Oral Maxillofac Surg; 1990 Dec; 28(6):393-7. PubMed ID: 2279039
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Planned to perfection? Use of the model repositioning instrument to plan maxillary movements for orthognathic surgery.
    Akram A; Collin J; Postlethwaite K; Sweeney G
    Orthodontics (Chic.); 2011; 12(2):130-3. PubMed ID: 21935506
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Two-step repositioning of the maxilla in bimaxillary orthognathic surgery.
    Masui I; Honda T; Uji T
    Br J Oral Maxillofac Surg; 1997 Feb; 35(1):64-6. PubMed ID: 9043009
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sequencing bimaxillary surgery: mandible first.
    Perez D; Ellis E
    J Oral Maxillofac Surg; 2011 Aug; 69(8):2217-24. PubMed ID: 21292376
    [No Abstract]   [Full Text] [Related]  

  • 5. A validation of two orthognathic model surgery techniques.
    Bamber MA; Harris M; Nacher C
    J Orthod; 2001 Jun; 28(2):135-42. PubMed ID: 11395528
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An accurate maxillary superior repositioning technique without intraoperative measurement in bimaxillary orthognathic surgery.
    Omura S; Kimizuka S; Iwai T; Tohnai I
    Int J Oral Maxillofac Surg; 2012 Aug; 41(8):949-51. PubMed ID: 22537516
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Positioning control of the upper incisors in orthognathic surgery. Pre-operative planning with the Model Positioning Device and intra-operative application of the Sandwich Splint.
    Schwestka R; Engelke D; Zimmer B; Kubein-Meesenburg D
    Eur J Orthod; 1991 Oct; 13(5):367-71. PubMed ID: 1748183
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A custom acrylic template for the transfer of reference lines and osteotomy from model surgery to the patient: an adjunct for Le Fort I osteotomy.
    LaBanc JP; Kendrick J
    Int J Adult Orthodon Orthognath Surg; 1987; 2(4):215-9. PubMed ID: 3483179
    [No Abstract]   [Full Text] [Related]  

  • 9. The significance of an erroneous recording of the centre of mandibular rotation in orthognathic surgery.
    Nattestad A; Vedtofte P; Mosekilde E
    J Craniomaxillofac Surg; 1991 Aug; 19(6):254-9. PubMed ID: 1939672
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical experiences of digital model surgery and the rapid-prototyped wafer for maxillary orthognathic surgery.
    Kim BC; Lee CE; Park W; Kim MK; Zhengguo P; Yu HS; Yi CK; Lee SH
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2011 Mar; 111(3):278-85.e1. PubMed ID: 20692187
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The role of the occlusal wafer in orthognathic surgery; a comparison of thick and thin intermediate osteotomy wafers.
    Bamber MA; Harris M
    J Craniomaxillofac Surg; 1995 Dec; 23(6):396-400. PubMed ID: 8839336
    [TBL] [Abstract][Full Text] [Related]  

  • 12. How accurate is model planning for orthognathic surgery?
    Sharifi A; Jones R; Ayoub A; Moos K; Walker F; Khambay B; McHugh S
    Int J Oral Maxillofac Surg; 2008 Dec; 37(12):1089-93. PubMed ID: 18760569
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new device for surgical splint construction.
    Yang SD
    J Clin Orthod; 2004 Jul; 38(7):367-72. PubMed ID: 15304948
    [No Abstract]   [Full Text] [Related]  

  • 14. Evaluation of an improved orthognathic articulator system. 2. Accuracy of occlusal wafers.
    Paul PE; Barbenel JC; Walker FS; Khambay BS; Moos KF; Ayoub AF
    Int J Oral Maxillofac Surg; 2012 Feb; 41(2):155-9. PubMed ID: 22047954
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Predictability of maxillary repositioning during bimaxillary surgery: accuracy of a new technique.
    Gil JN; Claus JD; Manfro R; Lima SM
    Int J Oral Maxillofac Surg; 2007 Apr; 36(4):296-300. PubMed ID: 17240117
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of an improved orthognathic articulator system: 1. Accuracy of cast orientation.
    Paul PE; Barbenel JC; Walker FS; Khambay BS; Moos KF; Ayoub AF
    Int J Oral Maxillofac Surg; 2012 Feb; 41(2):150-4. PubMed ID: 22047955
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Virtual model surgery and wafer fabrication for orthognathic surgery.
    Choi JY; Song KG; Baek SH
    Int J Oral Maxillofac Surg; 2009 Dec; 38(12):1306-10. PubMed ID: 19596555
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computerized cephalometric evaluation of orthognathic surgical precision and stability in relation to maxillary superior repositioning combined with mandibular advancement or setback.
    Donatsky O; Bjørn-Jørgensen J; Holmqvist-Larsen M; Hillerup S
    J Oral Maxillofac Surg; 1997 Oct; 55(10):1071-9; discussion 1079-80. PubMed ID: 9331229
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mandible-first sequence in bimaxillary orthognathic surgery: a systematic review.
    Borba AM; Borges AH; Cé PS; Venturi BA; Naclério-Homem MG; Miloro M
    Int J Oral Maxillofac Surg; 2016 Apr; 45(4):472-5. PubMed ID: 26603195
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Orthognathic positioning system: intraoperative system to transfer virtual surgical plan to operating field during orthognathic surgery.
    Polley JW; Figueroa AA
    J Oral Maxillofac Surg; 2013 May; 71(5):911-20. PubMed ID: 23312847
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.