These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. The necessity of achieving good laboratory performance. Fraser CG Diabet Med; 1990 Jul; 7(6):490-3. PubMed ID: 2142050 [TBL] [Abstract][Full Text] [Related]
3. Generation and application of analytical goals in laboratory medicine. Fraser CG Ann Ist Super Sanita; 1991; 27(3):369-75. PubMed ID: 1809055 [TBL] [Abstract][Full Text] [Related]
4. Relationship of quality goals and measurement performance to the selection of quality control procedures for multi-channel haematology analysers. Westgard JO; Cembrowski GS Eur J Haematol Suppl; 1990; 53():14-8. PubMed ID: 2279549 [TBL] [Abstract][Full Text] [Related]
5. Desirable standards for hematology tests: a proposal. Fraser CG Am J Clin Pathol; 1987 Nov; 88(5):667-9. PubMed ID: 3673948 [TBL] [Abstract][Full Text] [Related]
6. Desirable performance standards for imprecision and bias in alternate sites. The views of laboratory professionals. Fraser CG; Petersen PH Arch Pathol Lab Med; 1995 Oct; 119(10):909-13. PubMed ID: 7487389 [TBL] [Abstract][Full Text] [Related]
8. Desirable routine analytical goals for quantities assayed in serum. Discussion paper from the members of the external quality assessment (EQA) Working Group A on analytical goals in laboratory medicine. Stöckl D; Baadenhuijsen H; Fraser CG; Libeer JC; Petersen PH; Ricós C Eur J Clin Chem Clin Biochem; 1995 Mar; 33(3):157-69. PubMed ID: 7605829 [TBL] [Abstract][Full Text] [Related]
9. Analytical goals for quantities used to assess thyrometabolic status. Browning MC Ann Clin Biochem; 1989 Jan; 26 ( Pt 1)():1-12. PubMed ID: 2660738 [TBL] [Abstract][Full Text] [Related]
10. The application of theoretical goals based on biological variation data in proficiency testing. Fraser CG Arch Pathol Lab Med; 1988 Apr; 112(4):404-15. PubMed ID: 3355342 [TBL] [Abstract][Full Text] [Related]
11. Analytical Performance Verification of the Beckman Coulter AU5800 Clinical Chemistry Analyser Against Recognized Quality Specifications Reveals Relevance of Method Harmonization. Glibert B; Bourleaux V; Peeters R; Reynolds T; Vranken G Clin Lab; 2016; 62(1-2):57-72. PubMed ID: 27012034 [TBL] [Abstract][Full Text] [Related]
12. Analytical quality goals for 25-vitamin D based on biological variation. Viljoen A; Singh DK; Farrington K; Twomey PJ J Clin Lab Anal; 2011; 25(2):130-3. PubMed ID: 21438007 [TBL] [Abstract][Full Text] [Related]
13. Quality specification in haematology: the automated blood cell count. Buttarello M Clin Chim Acta; 2004 Aug; 346(1):45-54. PubMed ID: 15234635 [TBL] [Abstract][Full Text] [Related]
14. A new concept to derive permissible limits for analytical imprecision and bias considering diagnostic requirements and technical state-of-the-art. Haeckel R; Wosniok W Clin Chem Lab Med; 2011 Apr; 49(4):623-35. PubMed ID: 21345158 [TBL] [Abstract][Full Text] [Related]
15. Desirable standards for laboratory tests if they are to fulfill medical needs. Fraser CG; Petersen PH Clin Chem; 1993 Jul; 39(7):1447-53; discussion 1453-5. PubMed ID: 8330406 [TBL] [Abstract][Full Text] [Related]
16. Analytical goals developed from the inherent error of medical tests. Ross JW; Fraser MD Clin Chem; 1993 Jul; 39(7):1481-93; discussion 1493-4. PubMed ID: 8330410 [TBL] [Abstract][Full Text] [Related]