These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 22795598)

  • 21. Virological exploration of individuals with discordant HIV screening tests.
    Pasquier C; Sandres-Sauné K; Mansuy JM; Puissant B; Viraben R; Spenato N; Miédougé M; Massip P; Blancher A; Izopet J
    J Clin Virol; 2004 Jul; 30(3):218-23. PubMed ID: 15135738
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Evaluation of the performance of a new automated HIV combination assay.
    Ghisetti V; Coignard C; Allice T; Thoai Duong L
    J Clin Virol; 2017 Nov; 96():80-83. PubMed ID: 29020658
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of Detection Limits of Fourth- and Fifth-Generation Combination HIV Antigen-Antibody, p24 Antigen, and Viral Load Assays on Diverse HIV Isolates.
    Stone M; Bainbridge J; Sanchez AM; Keating SM; Pappas A; Rountree W; Todd C; Bakkour S; Manak M; Peel SA; Coombs RW; Ramos EM; Shriver MK; Contestable P; Nair SV; Wilson DH; Stengelin M; Murphy G; Hewlett I; Denny TN; Busch MP
    J Clin Microbiol; 2018 Aug; 56(8):. PubMed ID: 29793968
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluation of the performance of the Abbott ARCHITECT HIV Ag/Ab Combo Assay.
    Chavez P; Wesolowski L; Patel P; Delaney K; Owen SM
    J Clin Virol; 2011 Dec; 52 Suppl 1():S51-5. PubMed ID: 21983253
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of FDA licensed HIV assays using plasma from Cameroonian blood donors.
    Lee S; Hu J; Tang S; Wood O; Francis K; Machuca A; Rios M; Daniel S; Vockley C; Awazi B; Zekeng L; Hewlett I
    J Med Virol; 2006; 78 Suppl 1():S22-3. PubMed ID: 16622873
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Performance evaluation of a new fourth-generation HIV Ag/Ab combination electrochemiluminescence immunoassay - evaluation of a new HIV assay.
    Wang T; Li D; Yan K; Yuan Y; Yang T; Du X; Yan X; Tao C; Wang L
    Int J STD AIDS; 2014 Mar; 25(4):267-72. PubMed ID: 23970655
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Identification of early HIV infections using the fourth generation Abbott ARCHITECT HIV Ag/Ab Combo chemiluminescent microparticle immunoassay (CIA) in San Diego County.
    Manlutac AL; Giesick JS; McVay PA
    J Clin Virol; 2013 Dec; 58 Suppl 1():e44-7. PubMed ID: 24342477
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Early diagnosis of primary HIV infections: using a combined screening test (p24 antigen and anti-HIV antibodies)].
    Yerly S; Simon F; Perrin L
    Schweiz Med Wochenschr; 1999 Feb; 129(8):319-22. PubMed ID: 10189669
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Field evaluation of the Abbott ARCHITECT HIV Ag/Ab Combo immunoassay.
    Kfutwah A; Lemée V; Ngono HV; De Oliveira F; Njouom R; Plantier JC
    J Clin Virol; 2013 Dec; 58 Suppl 1():e70-5. PubMed ID: 24342480
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Performance evaluation of the new fully automated human immunodeficiency virus antigen-antibody combination assay designed for blood screening.
    Sickinger E; Jonas G; Yem AW; Goller A; Stieler M; Brennan C; Hausmann M; Schochetman G; Devare SG; Hunt JC; Kapprell HP; Bryant JD
    Transfusion; 2008 Apr; 48(4):584-93. PubMed ID: 18194389
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Clinical evaluation of BioPlex 2200 HIV Ag-Ab, an automated screening method providing discrete detection of HIV-1 p24 antigen, HIV-1 antibody, and HIV-2 antibody.
    Salmona M; Delarue S; Delaugerre C; Simon F; Maylin S
    J Clin Microbiol; 2014 Jan; 52(1):103-7. PubMed ID: 24153130
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Screening of HIV in blood banks. Evaluation of fourth generation kits].
    Canna F; Treviño E; Domínguez C; Gastaldello R; Barbas G; Cudola A; Irizar M; Bepre H; Gallego S
    Medicina (B Aires); 2003; 63(6):685-91. PubMed ID: 14719309
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Comparison of the clinical performance of the ECLusys HIV combi assay with the Lumipulse f and HISCL 2000-i HIV-1/2 ab screening assays].
    Sugiura A; Iwahara K; Suga Y; Uchiyama S; Maekawa M
    Rinsho Byori; 2012 Apr; 60(4):300-5. PubMed ID: 22686038
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Sensitivity and specificity of the new Bio-Rad HIV screening test, Access HIV combo V2.
    Guiraud V; Ciczora Y; Cardona M; Defer C; Gréaume S; Nogues D; Gautheret-Dejean A
    J Clin Microbiol; 2024 May; 62(5):e0009524. PubMed ID: 38534108
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Performance of the Alere Determine™ HIV-1/2 Ag/Ab Combo Rapid Test with specimens from HIV-1 seroconverters from the US and HIV-2 infected individuals from Ivory Coast.
    Masciotra S; Luo W; Youngpairoj AS; Kennedy MS; Wells S; Ambrose K; Sprinkle P; Owen SM
    J Clin Virol; 2013 Dec; 58 Suppl 1(Suppl 1):e54-8. PubMed ID: 23911678
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Development of a World Health Organisation International Reference Panel for Anti-HIV.
    Wigglesworth E; Heath A; Holmes H
    J Virol Methods; 2010 Jan; 163(1):101-8. PubMed ID: 19755131
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Measurement of HIV-1 p24 antigen by signal-amplification-boosted ELISA of heat-denatured plasma is a simple and inexpensive alternative to tests for viral RNA.
    Schüpbach J
    AIDS Rev; 2002; 4(2):83-92. PubMed ID: 12152521
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Assay for simultaneous detection of HIV p24 antigen and anti-HIV antibody].
    Xu K; Zhang Y; Wang Y; Mbawuike I
    Zhonghua Shi Yan He Lin Chuang Bing Du Xue Za Zhi; 2002 Dec; 16(4):377-9. PubMed ID: 12665911
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Performances of four fourth-generation human immunodeficiency virus-1 screening assays.
    Song EY; Hur M; Roh EY; Park MH; Moon HW; Yun YM
    J Med Virol; 2012 Dec; 84(12):1884-8. PubMed ID: 23080491
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of a new fourth generation enzyme-linked immunosorbent assay, the LG HIV Ag-Ab Plus, with a combined HIV p24 antigen and anti-HIV-1/2/O screening test.
    Yeom JS; Jun G; Chang Y; Sohn MJ; Yoo S; Kim E; Ryu SH; Kang HJ; Kim YA; Ahn SY; Cha JE; Youn ST; Park JW
    J Virol Methods; 2006 Nov; 137(2):292-7. PubMed ID: 16908076
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.