381 related articles for article (PubMed ID: 22797080)
1. SERS-based immunoassay using a gold array-embedded gradient microfluidic chip.
Lee M; Lee K; Kim KH; Oh KW; Choo J
Lab Chip; 2012 Oct; 12(19):3720-7. PubMed ID: 22797080
[TBL] [Abstract][Full Text] [Related]
2. On-chip immunoassay using surface-enhanced Raman scattering of hollow gold nanospheres.
Chon H; Lim C; Ha SM; Ahn Y; Lee EK; Chang SI; Seong GH; Choo J
Anal Chem; 2010 Jun; 82(12):5290-5. PubMed ID: 20503972
[TBL] [Abstract][Full Text] [Related]
3. Highly reproducible immunoassay of cancer markers on a gold-patterned microarray chip using surface-enhanced Raman scattering imaging.
Lee M; Lee S; Lee JH; Lim HW; Seong GH; Lee EK; Chang SI; Oh CH; Choo J
Biosens Bioelectron; 2011 Jan; 26(5):2135-41. PubMed ID: 20926277
[TBL] [Abstract][Full Text] [Related]
4. Simultaneous detection of duplex DNA oligonucleotides using a SERS-based micro-network gradient chip.
Choi N; Lee K; Lim DW; Lee EK; Chang SI; Oh KW; Choo J
Lab Chip; 2012 Dec; 12(24):5160-7. PubMed ID: 23081724
[TBL] [Abstract][Full Text] [Related]
5. SERS-Based Pump-Free Microfluidic Chip for Highly Sensitive Immunoassay of Prostate-Specific Antigen Biomarkers.
Gao R; Lv Z; Mao Y; Yu L; Bi X; Xu S; Cui J; Wu Y
ACS Sens; 2019 Apr; 4(4):938-943. PubMed ID: 30864786
[TBL] [Abstract][Full Text] [Related]
6. SERS decoding of micro gold shells moving in microfluidic systems.
Lee S; Joo S; Park S; Kim S; Kim HC; Chung TD
Electrophoresis; 2010 May; 31(10):1623-9. PubMed ID: 20419705
[TBL] [Abstract][Full Text] [Related]
7. Optofluidic platforms based on surface-enhanced Raman scattering.
Lim C; Hong J; Chung BG; deMello AJ; Choo J
Analyst; 2010 May; 135(5):837-44. PubMed ID: 20419230
[TBL] [Abstract][Full Text] [Related]
8. Highly sensitive immunoassay of lung cancer marker carcinoembryonic antigen using surface-enhanced Raman scattering of hollow gold nanospheres.
Chon H; Lee S; Son SW; Oh CH; Choo J
Anal Chem; 2009 Apr; 81(8):3029-34. PubMed ID: 19301845
[TBL] [Abstract][Full Text] [Related]
9. A reproducible surface-enhanced raman spectroscopy approach. Online SERS measurements in a segmented microfluidic system.
Strehle KR; Cialla D; Rösch P; Henkel T; Köhler M; Popp J
Anal Chem; 2007 Feb; 79(4):1542-7. PubMed ID: 17297953
[TBL] [Abstract][Full Text] [Related]
10. Detection of Hepatitis B virus antigen from human blood: SERS immunoassay in a microfluidic system.
Kamińska A; Witkowska E; Winkler K; Dzięcielewski I; Weyher JL; Waluk J
Biosens Bioelectron; 2015 Apr; 66():461-7. PubMed ID: 25497986
[TBL] [Abstract][Full Text] [Related]
11. Fast and sensitive detection of an anthrax biomarker using SERS-based solenoid microfluidic sensor.
Gao R; Ko J; Cha K; Jeon JH; Rhie GE; Choi J; deMello AJ; Choo J
Biosens Bioelectron; 2015 Oct; 72():230-6. PubMed ID: 25985198
[TBL] [Abstract][Full Text] [Related]
12. SERS-based immunoassay of tumor marker VEGF using DNA aptamers and silica-encapsulated hollow gold nanospheres.
Ko J; Lee S; Lee EK; Chang SI; Chen L; Yoon SY; Choo J
Phys Chem Chem Phys; 2013 Apr; 15(15):5379-85. PubMed ID: 23201966
[TBL] [Abstract][Full Text] [Related]
13. A SERS-based immunoassay with highly increased sensitivity using gold/silver core-shell nanorods.
Wu L; Wang Z; Zong S; Huang Z; Zhang P; Cui Y
Biosens Bioelectron; 2012; 38(1):94-9. PubMed ID: 22647534
[TBL] [Abstract][Full Text] [Related]
14. Manual-slide-engaged paper chip for parallel SERS-immunoassay measurement of clenbuterol from swine hair.
Zheng T; Gao Z; Luo Y; Liu X; Zhao W; Lin B
Electrophoresis; 2016 Feb; 37(3):418-24. PubMed ID: 26395181
[TBL] [Abstract][Full Text] [Related]
15. A vertical flow microarray chip based on SERS nanotags for rapid and ultrasensitive quantification of α-fetoprotein and carcinoembryonic antigen.
Zhang D; Huang L; Liu B; Ge Q; Dong J; Zhao X
Mikrochim Acta; 2019 Oct; 186(11):699. PubMed ID: 31617008
[TBL] [Abstract][Full Text] [Related]
16. Rapid analysis of alpha-fetoprotein by chemiluminescence microfluidic immunoassay system based on super-paramagnetic microbeads.
Huang H; Zheng XL; Zheng JS; Pan J; Pu XY
Biomed Microdevices; 2009 Feb; 11(1):213-6. PubMed ID: 18923903
[TBL] [Abstract][Full Text] [Related]
17. Additional amplifications of SERS via an optofluidic CD-based platform.
Choi D; Kang T; Cho H; Choi Y; Lee LP
Lab Chip; 2009 Jan; 9(2):239-43. PubMed ID: 19107279
[TBL] [Abstract][Full Text] [Related]
18. PDMS microfludic device for optical detection of protein immunoassay using gold nanoparticles.
Luo C; Fu Q; Li H; Xu L; Sun M; Ouyang Q; Chen Y; Ji H
Lab Chip; 2005 Jul; 5(7):726-9. PubMed ID: 15970965
[TBL] [Abstract][Full Text] [Related]
19. Microfluidic-SERS devices for one shot limit-of-detection.
Kim D; Campos AR; Datt A; Gao Z; Rycenga M; Burrows ND; Greeneltch NG; Mirkin CA; Murphy CJ; Van Duyne RP; Haynes CL
Analyst; 2014 Jul; 139(13):3227-3234. PubMed ID: 24756225
[TBL] [Abstract][Full Text] [Related]
20. Optofluidic SERS chip with plasmonic nanoprobes self-aligned along microfluidic channels.
Oh YJ; Jeong KH
Lab Chip; 2014 Mar; 14(5):865-8. PubMed ID: 24452813
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]