These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

182 related articles for article (PubMed ID: 22801348)

  • 1. Rapid plasma reagin titer variation in the 2 weeks after syphilis therapy.
    Holman KM; Wolff M; Seña AC; Martin DH; Behets F; Van Damme K; Leone P; McNeil L; Gehrig ML; Hook EW
    Sex Transm Dis; 2012 Aug; 39(8):645-7. PubMed ID: 22801348
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A randomized, comparative pilot study of azithromycin versus benzathine penicillin G for treatment of early syphilis.
    Hook EW; Martin DH; Stephens J; Smith BS; Smith K
    Sex Transm Dis; 2002 Aug; 29(8):486-90. PubMed ID: 12172535
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Usefulness of Automated Latex Turbidimetric Rapid Plasma Reagin Test for Diagnosis and Evaluation of Treatment Response in Syphilis in Comparison with Manual Card Test: a Prospective Cohort Study.
    Tsuboi M; Nishijima T; Aoki T; Teruya K; Kikuchi Y; Gatanaga H; Oka S
    J Clin Microbiol; 2018 Nov; 56(11):. PubMed ID: 30135229
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rate of Decline in Nontreponemal Antibody Titers and Seroreversion After Treatment of Early Syphilis.
    Seña AC; Wolff M; Behets F; Martin DH; Leone P; Langley C; McNeil L; Hook EW
    Sex Transm Dis; 2017 Jan; 44(1):6-10. PubMed ID: 27898575
    [TBL] [Abstract][Full Text] [Related]  

  • 5. What Is the Role of Paired Rapid Plasma Reagin Testing (Simultaneous Testing of Acute and Convalescent Samples) in the Diagnosis of Repeat Syphilis and the Follow-up of Syphilis?
    Kenyon CR; Osbak KK; Van Esbroek M; Lynen L; Crucitti T
    Sex Transm Dis; 2018 Jan; 45(1):35-38. PubMed ID: 28876300
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Challenges of Rapid Plasma Reagin Interpretation in Syphilis Screening in Uganda: Variability in Nontreponemal Results Between Different Laboratories.
    Hamill MM; Mbazira KJ; Kiragga AN; Gaydos CA; Jett-Goheen M; Parkes-Ratanshi R; Manabe YC; Nakku-Joloba E; Rompalo A
    Sex Transm Dis; 2018 Dec; 45(12):829-833. PubMed ID: 29944643
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the BioPlex 2200 syphilis total screen (IgG/IgM) with reflex to an automated rapid plasma reagin test.
    Rourk AR; Litwin CM
    J Clin Lab Anal; 2019 Jun; 33(5):e22878. PubMed ID: 30861169
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of specific antibodies for early diagnosis and management of syphilis.
    Dang Q; Feng J; Lu X; Zhang X; Xu H; Liu C; Nu X
    Int J Dermatol; 2006 Oct; 45(10):1169-71. PubMed ID: 17040431
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The laboratory impact of changing syphilis screening from the rapid-plasma reagin to a treponemal enzyme immunoassay: a case-study from the Greater Toronto Area.
    Mishra S; Boily MC; Ng V; Gold WL; Okura T; Shaw M; Mazzulli T; Fisman DN
    Sex Transm Dis; 2011 Mar; 38(3):190-6. PubMed ID: 20706176
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of serological responses to single-dose azithromycin (2 g) versus benzathine penicillin G in the treatment of early syphilis in HIV-infected patients in an area of low prevalence of macrolide-resistant Treponema pallidum infection.
    Yang CJ; Tang HJ; Chang SY; Hsieh SM; Lee KY; Lee YT; Sheng WH; Yang SP; Hung CC; Chang SC
    J Antimicrob Chemother; 2016 Mar; 71(3):775-82. PubMed ID: 26604241
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the fully automated AIX1000 rapid plasma reagin system compared to a manual plasma reagin testing method for the diagnosis of syphilis.
    Pyden A; Kang AD; Amato S; Dutta S; Berg G; Riedel S
    Diagn Microbiol Infect Dis; 2020 Aug; 97(4):115081. PubMed ID: 32534240
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of BioPlex 2200 Syphilis Total With Automated Rapid Plasma Reagin: Experience From a Tertiary Medical Center.
    Tang EW; Paiva KJ; Pytel-Parenteau DL; Maynard MA; Chan PA; Lu S
    Sex Transm Dis; 2020 May; 47(5):301-305. PubMed ID: 32073549
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of a Rapid Syphilis Test in an Emergency Department Setting in Detroit, Michigan.
    Fakile YF; Markowitz N; Zhu W; Mumby K; Dankerlui D; McCormick JK; Ham DC; Hopkins A; Manteuffel J; Sun Y; Huang YA; Peters PJ; Hoover KW
    Sex Transm Dis; 2019 Jul; 46(7):429-433. PubMed ID: 30839394
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Repeat syphilis has a different immune response compared with initial syphilis: an analysis of biomarker kinetics in two cohorts.
    Kenyon C; Tsoumanis A; Osbak K; Van Esbroeck M; Florence E; Crucitti T; Kestens L
    Sex Transm Infect; 2018 May; 94(3):180-186. PubMed ID: 29021408
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characteristics of patients with primary and late latent syphilis patients who were initially non-reactive to the rapid plasma reagin test.
    Jun L; He-Yi Z
    Jpn J Infect Dis; 2013; 66(1):36-40. PubMed ID: 23429083
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A retrospective study on rapid plasma reagin testing in patients with Pityriasis rosea.
    Halteh P; Lipner SR
    Int J STD AIDS; 2017 Nov; 28(13):1348-1351. PubMed ID: 28345391
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Factors associated with serological cure and the serofast state of HIV-negative patients with primary, secondary, latent, and tertiary syphilis.
    Tong ML; Lin LR; Liu GL; Zhang HL; Zeng YL; Zheng WH; Liu LL; Yang TC
    PLoS One; 2013; 8(7):e70102. PubMed ID: 23894598
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Serologic response to treatment of infectious syphilis.
    Romanowski B; Sutherland R; Fick GH; Mooney D; Love EJ
    Ann Intern Med; 1991 Jun; 114(12):1005-9. PubMed ID: 2029095
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Sensitivity and specificity of ELISA based on recombinant Treponema pallidum antigen and rapid plasma reagin test in diagnosis of syphilis: a comparative study].
    Wang LN; Zheng HY; Li J; Wang XF; Liu XR
    Zhonghua Yi Xue Za Zhi; 2007 Jun; 87(24):1721-2. PubMed ID: 17825160
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of an automated rapid plasma reagin (RPR) test with the conventional RPR card test in syphilis testing.
    Lee JH; Lim CS; Lee MG; Kim HS
    BMJ Open; 2014 Dec; 4(12):e005664. PubMed ID: 25552608
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.