These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
287 related articles for article (PubMed ID: 22815129)
1. Oxygen saturation in pulse oximetry in hemoglobin anomalies. Zur B; Bagci S; Ludwig M; Stoffel-Wagner B Klin Padiatr; 2012 Jul; 224(4):259-65. PubMed ID: 22815129 [TBL] [Abstract][Full Text] [Related]
2. Case-control studies of novel hemoglobin anomalies as differential diagnosis in sleep apnea syndrome. Zur B; Ludwig M; Stoffel-Wagner B Sleep Breath; 2013 May; 17(2):557-63. PubMed ID: 22581484 [TBL] [Abstract][Full Text] [Related]
3. Low oxygen saturation by pulse oximetry may be associated with a low oxygen affinity hemoglobin variant, hemoglobin Titusville. Deyell R; Jackson S; Spier S; Le D; Poon MC J Pediatr Hematol Oncol; 2006 Feb; 28(2):100-2. PubMed ID: 16462584 [TBL] [Abstract][Full Text] [Related]
4. A novel hemoglobin, Bonn, causes falsely decreased oxygen saturation measurements in pulse oximetry. Zur B; Hornung A; Breuer J; Doll U; Bernhardt C; Ludwig M; Stoffel-Wagner B Clin Chem; 2008 Mar; 54(3):594-6. PubMed ID: 18310146 [TBL] [Abstract][Full Text] [Related]
6. Capillary Electrophoresis Resolves Inconclusive HPLC Analysis for Hemoglobin Variants: a Study of Two Cases. Li Y; Tian M; Qin T; Wan L Clin Lab; 2018 Jul; 64(7):1305-1309. PubMed ID: 30146834 [TBL] [Abstract][Full Text] [Related]
8. Haemoglobin Bonn in a Chinese family as a cause of spurious hypoxaemia measured by pulse oximetry. So CC; Chan AY; Chow EY; Lin SY; Yip SF; Szeto SC; Chan LC J Clin Pathol; 2010 Oct; 63(10):947-9. PubMed ID: 20876330 [TBL] [Abstract][Full Text] [Related]
9. Hemoglobin Kansas as a Rare Cause of Cyanosis: A Case Report and Review of the Literature. Nagayama Y; Yoshida M; Kohyama T; Matsui K Intern Med; 2017; 56(2):207-209. PubMed ID: 28090054 [TBL] [Abstract][Full Text] [Related]
10. Hemoglobin Denver, a cause of desaturated pulse oximetry. A pediatric case report. Rossetti E; Eandi Eberle S; Aguirre F; Pepe C; Díaz L; Harris V; Ávalos V Arch Argent Pediatr; 2023 Oct; 121(5):e202202801. PubMed ID: 36857142 [TBL] [Abstract][Full Text] [Related]
11. First Family Case of Hemoglobinopathy Titusville in China with Falsely Low SpO2 and Unmeasurable SaO2. Chen YX; He JJ; Yu YY; Dai W; Zhang G Clin Lab; 2024 Mar; 70(3):. PubMed ID: 38469764 [TBL] [Abstract][Full Text] [Related]
12. Hb Grove City [β38(C4)Thr→Ser, ACC>AGC; HBB: c.116C>G]: a new low oxygen affinity β chain variant. Taliercio RM; Ashton RW; Horwitz L; Swanson KC; Wendt PC; Hoyer JD; Oliveira JL Hemoglobin; 2013; 37(4):396-403. PubMed ID: 23651408 [TBL] [Abstract][Full Text] [Related]
13. Comparison of Sebia Capillarys Flex capillary electrophoresis with the BioRad Variant II high pressure liquid chromatography in the evaluation of hemoglobinopathies. Greene DN; Pyle AL; Chang JS; Hoke C; Lorey T Clin Chim Acta; 2012 Aug; 413(15-16):1232-8. PubMed ID: 22515960 [TBL] [Abstract][Full Text] [Related]
14. Apparent desaturation on pulse oximetry because of hemoglobinopathy. Mounts J; Clingenpeel J; White N; Villella A Pediatr Emerg Care; 2010 Oct; 26(10):748-9. PubMed ID: 20930596 [TBL] [Abstract][Full Text] [Related]
15. Dyshemoglobinemias and pulse oximetry: a therapeutic challenge. Hladik A; Lynshue K J Pediatr Hematol Oncol; 2008 Nov; 30(11):850-2. PubMed ID: 18989162 [TBL] [Abstract][Full Text] [Related]
16. Hb Kenya among Luo adults and young children in malaria holoendemic Western Kenya: screened by high performance liquid chromatography and confirmed by polymerase chain reaction. Kifude CM; Polhemus ME; Heppner DG; Withers MR; Ogutu BR; Waitumbi JN Hemoglobin; 2007; 31(4):401-8. PubMed ID: 17994373 [TBL] [Abstract][Full Text] [Related]
17. Oxygen Saturation of 75%, but No Symptoms! Guler S; Brunner-Agten S; Bartenstein S; Bettschen HU; Geiser T; Keller P; Funke M Respiration; 2016; 92(6):420-424. PubMed ID: 27760425 [No Abstract] [Full Text] [Related]
18. Decreased oxygen saturation as a result of haemoglobin Titusville. Avellan-Hietanen H; Aittomaki J; Ekroos H; Aittomäki K; Turpeinen U; Kalkkinen N; Sovijärvi A Clin Respir J; 2008 Oct; 2(4):242-4. PubMed ID: 20298341 [TBL] [Abstract][Full Text] [Related]
19. Low Oxygen Affinity Variant Haemoglobin in an elderly woman presenting with low oxygen saturation. Igbineweka NE; Horne GA; Jackson MB; Chevassut TJ Acute Med; 2015; 14(2):72-6. PubMed ID: 26305085 [TBL] [Abstract][Full Text] [Related]
20. Hemoglobinopathy case finding by pulse oximetry. Bruns CM; Thet LA; Woodson RD; Schultz J; Hla KM Am J Hematol; 2003 Oct; 74(2):142-3. PubMed ID: 14508804 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]