These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 2281882)

  • 1. Regulating knee joint position by combining electrical stimulation with a controllable friction brake.
    Durfee WK; Hausdorff JM
    Ann Biomed Eng; 1990; 18(6):575-96. PubMed ID: 2281882
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Preliminary evaluation of a controlled-brake orthosis for FES-aided gait.
    Goldfarb M; Korkowski K; Harrold B; Durfee W
    IEEE Trans Neural Syst Rehabil Eng; 2003 Sep; 11(3):241-8. PubMed ID: 14518787
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Control of standing and gait using electrical stimulation: influence of muscle model complexity on control strategy.
    Durfee WK
    Prog Brain Res; 1993; 97():369-81. PubMed ID: 8234762
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Design and simulation of closed-loop electrical stimulation orthoses for restoration of quiet standing in paraplegia.
    Jaeger RJ
    J Biomech; 1986; 19(10):825-35. PubMed ID: 3782165
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Feasibility of a hybrid-FES system for gait restoration in paraplegics.
    Quintero HA; Farris RJ; Durfee WK; Goldfarb M
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():483-6. PubMed ID: 21096305
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimal control of FES-assisted standing up in paraplegia using genetic algorithms.
    Davoodi R; Andrews BJ
    Med Eng Phys; 1999 Nov; 21(9):609-17. PubMed ID: 10699563
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Open-loop position control of the knee joint using electrical stimulation of the quadriceps and hamstrings.
    Hausdorff JM; Durfee WK
    Med Biol Eng Comput; 1991 May; 29(3):269-80. PubMed ID: 1943259
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design and Test of a Biomechanical Model for the Estimation of Knee Joint Angle During Indoor Rowing: Implications for FES-Rowing Protocols in Paraplegia.
    Vieira T; Cerone GL; Gastaldi L; Pastorelli S; Oliveira LF; Gazzoni M; Botter A
    IEEE Trans Neural Syst Rehabil Eng; 2018 Nov; 26(11):2145-2152. PubMed ID: 30334801
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Low-level finite state control of knee joint in paraplegic standing.
    Mulder AJ; Veltink PH; Boom HB; Zilvold G
    J Biomed Eng; 1992 Jan; 14(1):3-8. PubMed ID: 1569737
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new hybrid spring brake orthosis for controlling hip and knee flexion in the swing phase.
    Gharooni S; Heller B; Tokhi MO
    IEEE Trans Neural Syst Rehabil Eng; 2001 Mar; 9(1):106-7. PubMed ID: 11482357
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of joint motion constraints on the gait of normal subjects and their implications on the further development of hybrid FES orthosis for paraplegic persons.
    Yang L; Condie DN; Granat MH; Paul JP; Rowley DI
    J Biomech; 1996 Feb; 29(2):217-26. PubMed ID: 8849815
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An electrical knee lock system for functional electrical stimulation.
    Kagaya H; Shimada Y; Sato K; Sato M; Iizuka K; Obinata G
    Arch Phys Med Rehabil; 1996 Sep; 77(9):870-3. PubMed ID: 8822676
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Model-based control of FES-induced single joint movements.
    Ferrarin M; Palazzo F; Riener R; Quintern J
    IEEE Trans Neural Syst Rehabil Eng; 2001 Sep; 9(3):245-57. PubMed ID: 11561660
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hybrid functional electrical stimulation with medial linkage knee-ankle-foot orthoses in complete paraplegics.
    Shimada Y; Hatakeyama K; Minato T; Matsunaga T; Sato M; Chida S; Itoi E
    Tohoku J Exp Med; 2006 Jun; 209(2):117-23. PubMed ID: 16707853
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of simulation and experiments of different closed-loop strategies for functional electrical stimulation: experiments in paraplegics.
    Quintern J; Riener R; Rupprecht S
    Artif Organs; 1997 Mar; 21(3):232-5. PubMed ID: 9148713
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of powered gait orthosis on walking in individuals with paraplegia.
    Arazpour M; Ahmadi Bani M; Kashani RV; Tabatabai Ghomshe F; Mousavi ME; Hutchins SW
    Prosthet Orthot Int; 2013 Aug; 37(4):261-7. PubMed ID: 23172910
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Closed-Loop Asynchronous Neuromuscular Electrical Stimulation Prolongs Functional Movements in the Lower Body.
    Downey RJ; Cheng TH; Bellman MJ; Dixon WE
    IEEE Trans Neural Syst Rehabil Eng; 2015 Nov; 23(6):1117-27. PubMed ID: 25935038
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sliding mode closed-loop control of FES: controlling the shank movement.
    Jezernik S; Wassink RG; Keller T
    IEEE Trans Biomed Eng; 2004 Feb; 51(2):263-72. PubMed ID: 14765699
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of closed-loop control algorithms for regulating electrically stimulated knee movements in individuals with spinal cord injury.
    Lynch CL; Popovic MR
    IEEE Trans Neural Syst Rehabil Eng; 2012 Jul; 20(4):539-48. PubMed ID: 22772375
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Gait evaluation of a novel hip constraint orthosis with implication for walking in paraplegia.
    Audu ML; To CS; Kobetic R; Triolo RJ
    IEEE Trans Neural Syst Rehabil Eng; 2010 Dec; 18(6):610-8. PubMed ID: 20378478
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.