BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 22821374)

  • 21. Application of 3D-MR image registration to monitor diseases around the knee joint.
    Takao M; Sugano N; Nishii T; Miki H; Koyama T; Masumoto J; Sato Y; Tamura S; Yoshikawa H
    J Magn Reson Imaging; 2005 Nov; 22(5):656-60. PubMed ID: 16215970
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Unsupervised fully automated inline analysis of global left ventricular function in CINE MR imaging.
    Theisen D; Sandner TA; Bauner K; Hayes C; Rist C; Reiser MF; Wintersperger BJ
    Invest Radiol; 2009 Aug; 44(8):463-8. PubMed ID: 19561514
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Unifying framework for multimodal brain MRI segmentation based on Hidden Markov Chains.
    Bricq S; Collet Ch; Armspach JP
    Med Image Anal; 2008 Dec; 12(6):639-52. PubMed ID: 18440268
    [TBL] [Abstract][Full Text] [Related]  

  • 24. An efficient level set method for simultaneous intensity inhomogeneity correction and segmentation of MR images.
    Ivanovska T; Laqua R; Wang L; Schenk A; Yoon JH; Hegenscheid K; Völzke H; Liebscher V
    Comput Med Imaging Graph; 2016 Mar; 48():9-20. PubMed ID: 26741125
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Anatomically constrained region deformation for the automated segmentation of the hippocampus and the amygdala: Method and validation on controls and patients with Alzheimer's disease.
    Chupin M; Mukuna-Bantumbakulu AR; Hasboun D; Bardinet E; Baillet S; Kinkingnéhun S; Lemieux L; Dubois B; Garnero L
    Neuroimage; 2007 Feb; 34(3):996-1019. PubMed ID: 17178234
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Analysis of 3-D myocardial motion in tagged MR images using nonrigid image registration.
    Chandrashekara R; Mohiaddin RH; Rueckert D
    IEEE Trans Med Imaging; 2004 Oct; 23(10):1245-50. PubMed ID: 15493692
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Reconstruction of three-dimensional occluded object using optical flow and triangular mesh reconstruction in integral imaging.
    Jung JH; Hong K; Park G; Chung I; Park JH; Lee B
    Opt Express; 2010 Dec; 18(25):26373-87. PubMed ID: 21164988
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Automated 3-dimensional elastic registration of whole-body PET and CT from separate or combined scanners.
    Shekhar R; Walimbe V; Raja S; Zagrodsky V; Kanvinde M; Wu G; Bybel B
    J Nucl Med; 2005 Sep; 46(9):1488-96. PubMed ID: 16157532
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Reconstruction of magnetic resonance imaging by three-dimensional dual-dictionary learning.
    Song Y; Zhu Z; Lu Y; Liu Q; Zhao J
    Magn Reson Med; 2014 Mar; 71(3):1285-98. PubMed ID: 23554046
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Generation of curved planar reformations from magnetic resonance images of the spine.
    Vrtovec T; Ourselin S; Gomes L; Likar B; Pernus F
    Med Image Comput Comput Assist Interv; 2006; 9(Pt 2):135-43. PubMed ID: 17354765
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Reconstruction of MRI data encoded with arbitrarily shaped, curvilinear, nonbijective magnetic fields.
    Schultz G; Ullmann P; Lehr H; Welz AM; Hennig J; Zaitsev M
    Magn Reson Med; 2010 Nov; 64(5):1390-403. PubMed ID: 20848635
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Isotropic reconstruction of a 4-D MRI thoracic sequence using super-resolution.
    Van Reeth E; Tan CH; Tham IW; Poh CL
    Magn Reson Med; 2015 Feb; 73(2):784-93. PubMed ID: 24478231
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Volume reconstruction by inverse interpolation: application to interleaved MR motion correction.
    Rohlfing T; Rademacher MH; Pfefferbaum A
    Med Image Comput Comput Assist Interv; 2008; 11(Pt 1):798-806. PubMed ID: 18979819
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Spine detection and labeling using a parts-based graphical model.
    Schmidt S; Kappes J; Bergtholdt M; Pekar V; Dries S; Bystrov D; Schnörr C
    Inf Process Med Imaging; 2007; 20():122-33. PubMed ID: 17633694
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Deformable mosaicing for whole-body MRI.
    Wachinger C; Glocker B; Zeltner J; Paragios N; Komodakis N; Hansen MS; Navab N
    Med Image Comput Comput Assist Interv; 2008; 11(Pt 2):113-21. PubMed ID: 18982596
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Incorporation of image data from a previous examination in 3D serial MR imaging.
    Li G; Hennig J; Raithel E; Büchert M; Paul D; Korvink JG; Zaitsev M
    MAGMA; 2015 Oct; 28(5):413-25. PubMed ID: 25572444
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Error optimization of a three-dimensional magnetic resonance imaging tagging-based cartilage deformation technique.
    Neu CP; Hull ML; Walton JH
    Magn Reson Med; 2005 Nov; 54(5):1290-4. PubMed ID: 16200566
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Multi-modal registration of speckle-tracked freehand 3D ultrasound to CT in the lumbar spine.
    Lang A; Mousavi P; Gill S; Fichtinger G; Abolmaesumi P
    Med Image Anal; 2012 Apr; 16(3):675-86. PubMed ID: 21982123
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Field-warp registration for biomedical high-resolution thermal infrared images.
    Tangherlini A; Merla A; Romani GL
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():961-4. PubMed ID: 17946013
    [TBL] [Abstract][Full Text] [Related]  

  • 40. GReTA-A Novel Global and Recursive Tracking Algorithm in Three Dimensions.
    Attanasi A; Cavagna A; Castello LD; Giardina I; Jelic A; Melillo S; Parisi L; Pellacini F; Shen E; Silvestri E; Viale M
    IEEE Trans Pattern Anal Mach Intell; 2015 Dec; 37(12):2451-63. PubMed ID: 26539850
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.